16
CHAPTER2 Configuration and Connection
2-2
Connecting the Power Supply
2-2-1
Power supply
■
ERCX controller
DriverType
-
No. of phases
-
Frequency
-
Max. power consumption
3 A
Power supply voltage
DC24V
±
10%
■
SRCX controller
DriverType
05
10
20
No. of phases
Single phase
Single phase
Single phase
Frequency
50/60Hz
50/60Hz
50/60Hz
Max. power consumption
400 VA
600 VA
1000 VA
Power supply voltage
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
■
DRCX controller
DriverType
0505
0510
0520
1005
1010
1020
2005
2010
2020
No. of phases
Single phase
Single phase
Single phase
Single phase
Single phase
Single phase
Single phase
Single phase
Single phase
Frequency
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
Max. power consumption
500 VA or less
700 VA or less
1100 VA or less
700 VA or less
900 VA or less
1300 VA or less
1100 VA or less
1300 VA or less
1600 VA or less
Power supply voltage
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
AC200V
±
10%
C A U T I O N
C A U T I O N
C A U T I O N
On the SRCX and DRCX controllers designed for CE marking, the power supply must
be AC 200V
±
10%.
If the power supply voltage drops below the above listed range during operation, an
alarm circuit triggers so that the controller operation misht return to the initial conditions
or come to an alarm stop. To avoid such problems from power supply fluctuations, a
stable power supply with less than
±
10% fluctuation should be used.
The controller has a capacitor input type power supply, so a large current surge occurs
when the power is turned on. Avoid using quick-blow circuit breakers and fuses.
For the same reason, avoid turning the power off and on again repeatedly within an
interval of less than 10 seconds. This could eventually damage the main circuit elements
in the controller.