Scene memory
Reference Manual
87
Using the Focus function
“Focus” is a function that lets you specify the scene parameters that will be recalled (loaded) when you
recall a scene. You can specify these settings for each scene. This function is useful if you want to recall
only the input channel settings of a specific scene.
NOTE
In contrast to Focus, the CL series console features a “Recall Safe” function that enables you to
exclude specific channels and parameters from recall operations. However while the Focus
function is specified for each scene, Recall Safe settings are applied to all scenes.
1.
Press the SCENE field in the Function Access Area.
The SCENE LIST window will appear, in which you can perform various operations for scene
memory.
2.
Press the FOCUS tab at the bottom of the SCENE LIST window.
The FOCUS field will appear in the right half of the SCENE LIST window.
1
FOCUS button
Enables or disables the Focus function for each scene.
2
SET popup button
Press this button to access the FOCUS RECALL popup screen, which allows you to select the
parameters that will be subject to recall.
3
FOCUS PARAMETER indicators
These indicators show the focus recall settings that are specified for each scene.
4
CURRENT SETTING field
Here you can specify the content that will be saved by the next scene store operation.
3.
Press the SET button for the scene you want to set.
The FOCUS RECALL popup window will appear. The window contains the following items.
1
CLEAR ALL button/SET ALL button
Turns off (or on) all focus channel selections and global focus parameter settings.
■
Focus channel display field
Indicates the target channel for a Recall operation. The view of this field is the same as that in the
RECALL SAFE popup window.
To add channels as the target, turn the SET BY SEL button
2
on, and then press the corresponding
[SEL] keys for the desired channels.
2
SET BY SEL button
Turn on this button to add a channel by using the corresponding [SEL] key. When you press the
[SEL] key of a channel, the on-screen fader of the corresponding channel will turn green (all
parameters will be recalled) or blue (only some parameters will be recalled). Press the same [SEL]
key once again to de-select the channel.
NOTE
In the case of the CL3/CL1, channels that do not exist on those models will not be shown.
1 2
3
4
2
3
1