3 - 51
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
5. Charge:
•
battery
(refer to the appropriate charging method
illustration)
WARNING
_
Do not quick charge a battery.
CAUTION:
_
•
Never remove the MF battery sealing
caps.
•
Do not use a high-rate battery charger
since it forces a high-amperage current
into the battery quickly and can cause
battery overheating and battery plate
damage.
•
If it is impossible to regulate the charging
current on the battery charger, be careful
not to overcharge the battery.
•
When charging a battery, be sure to
remove it from the scooter. (If charging
has to be done with the battery mounted
on the scooter, disconnect the negative
battery lead from the battery terminal.)
•
To reduce the chance of sparks, do not
plug in the battery charger until the bat-
tery charger leads are connected to the
battery.
•
Before removing the battery charger lead
clips from the battery terminals, be sure
to turn off the battery charger.
•
Make sure the battery charger lead clips
are in full contact with the battery termi-
nal and that they are not shorted. A cor-
roded battery charger lead clip may
generate heat in the contact area and a
weak clip spring may cause sparks.
•
If the battery becomes hot to the touch at
any time during the charging process,
disconnect the battery charger and let the
battery cool before reconnecting it. Hot
batteries can explode!
•
As shown in the following illustration, the
open-circuit voltage of an MF battery stabi-
lizes about 30 minutes after charging has
been completed. Therefore, wait 30 min-
utes after charging is completed before
measuring the open-circuit voltage.
Ope
n
-circuit v
o
lta
ge (V)
Charging
Time (minutes)
Check the open-circuit
voltage.
Ambient temperature 20
°
C (68
°
F)
Ope
n
-circuit v
o
lta
ge (V)
Charging condition of the battery (%)
Ambient tem-
perature
20
°
C (68
°
F)
Downloaded