12
4.3 Consumables
1
)
Pump
Refer to “Instruction Manual for APP 067U” for replacement time for consumables used in the pump. The
replacement time should be used only as a guide. Consumption varies depending on use conditions. Also, be
sure to replace a part when you find any defect like a leak during operation.
2
)
Lift
- The plastic tubes will be degraded naturally. Replace them all every six years.
- The switches and regulators should be replaced if you find they are not working properly. Never use a defective
device.
3
)
Inductor Plate
- The packing will get worn out due to sliding contact with a pail.
- The gasket used for the connection between the pump and inductor plate will get worn out by repetitive
mounting and removal of the inductor plate. Replace it with a new one when it is damaged at the time of
inductor plate removal.
4.4 Design standard use period
Design standard use period is established for the product. (See the table below.)
Use of the product beyond this period may result in personal injury or property damage.
- Pump
…
Refer to “Instruction Manual for APP 067U”.
- Lift and inductor plate
…
10 years
Application
Pumping and transferring grease
Season
Spring and Fall
Temperature
20°C
Material being pumped
Lithium Soap Grease: No.1
Container
Steel pail (20L): JIS Z 1620
Operating pressure for lift
0.4MPa
Daily Amount of Material being pumped
100L
Operating Days per year
260 days (5 days a week)
Standard Conditions of Use for Lift and Inductor Plate