Yale SmartHome Alarm series User Manual Download Page 8

  

Part Arm 1/2/3

The Part Arm Mode is used when 
the user wish to secure part of the 
premise while leaving the another 
area free to roam.  Part arm #2 and 
#3 will only be shown if they were 
enabled by installer/engineer.

 If Area 2 is defined, the system may 
ask you to choose one of the areas 
for arming (if the user have access 
to both areas). To part arm the 
system:

Keyfob- Press Part arm
Keypad- Enter pincode follow by 
pressing Part arm. 
Control panel- In Alarm off mode, 
enter pincode and press ok. Select 
Part arm 1, 2 or 3 and press ok. 
Alternatively press “1” for Part arm 
#1, “2” for Part arm #2, “3” for Part 
arm #3. On the screen it will show:

  

  time to exit
      30 sec

When the entry delay time expires, 
the control panel will emit a long 
beep. The LCD will display Part Arm 
1/2/3 and the system is now in the 
part arm mode. 

  

Lone Occupant

The Lone Occupant mode allows 
a user to deactivate (bypass) any 

sensors so that it will not trigger the 
Alarm for one-time only operation.  

This feature is ideal when the 
occupant plans to stay in one area 
for a prolonged length of time, and 
they wish to arm all other areas.

Step 1.  Select Lone Occupant or 
just press the shortcut key 4  on the 
control panel (under the user menu 
screen).  They system will now enter 
300 seconds count down. 

  

 lone occupant
 300 sec

Step 2.  Any sensor which is 
triggered (either by motion or by 
pressing the test/learn button) 
during the  countdown period will 
be bypassed. The panel will sound 
a warning beep every time a sensor 
is triggered during this countdown 
period.

8

Summary of Contents for SmartHome Alarm series

Page 1: ... Arming with Door Opened 9 Arming with Supervisory Fault 10 Set Time Date 10 Time 10 Date 10 Year 10 Daylight 11 ByPass Sensor 11 RSPS ILPS ZE88 12 Event Log 12 Change Pincode 12 GSM 12 Master Setup 13 User Setting 13 Engineer Access 15 Alarm Clock 15 Panel Key LED 15 Status LED 15 Answer Machine 15 Front Tamper 16 Desk Tamper 16 PSTN and GSM GPRS Functions Telephone function 17 Remote Command 17 ...

Page 2: ...Occupant mode Control panel When Alarm off enter pincode press 4 Keypad Enter pincode press the associated Lone occup button Keyfob Press the associated Lone occupant button Disarm Control panel Enter pincode press ok Keypad Enter pincode press the Disarm button Keyfob Press the Disarm button Other functions Change your pincode User menu Change pincode Contact Engineer Press hold up key for 5 sec ...

Page 3: ...l Arm Key Used as a numeric key Also used to Full Arm the system 9 Engineer Programming Menu Key 10 Numeric Key 4 Lone Occupant Key Used as a numeric key The shortcut key used to enable the Lone Occupant mode 11 Numeric Key 1 2 3 Part Arm 1 2 3 Used as a numeric keys Shortcut for Part Arm 1 2 3 modes 12 Speaker 13 OK Enter Yes Key Used to confirm the selection 14 Return No Key Used to delete enter...

Page 4: ...vent log change pincode gsm master setup Notes 1 Fault List is only shown if there is a fault event in the system 2 Selection shown will depends on User attribute setting 3 Part Arm 2 and 3 will be shown if enabled 4 RSPS ILPS ZE88 and GSM will only be shown if the relevant device exists in the system 5 If a Master pincode was used the option Master Setup will be shown 6 Hear Answer MC Machine is ...

Page 5: ... Should the user require further assistant during system operation press the i button to playback supplementary information Press the i button for a second time during playback to stop this function Duress code Under a holdup situation the user maybe required to arm or disarm the alarm system In order to avoid aggravating the situation duress code can be used for arming and disarming is provided t...

Page 6: ...achine option is enabled and the control panel is connected to either the GSM GPRS or PSTN phone line When the caller leaves messages on the system this option will be shown Once selected it will inform you if there are more than one recording max 20 voice messages there are 02 records It will then proceed to playback all the messages starting from the oldest message Message order and the time dat...

Page 7: ...en the door contact delay attribute is closed i e user left the property Stop Entry Delay During the entry countdown the user can prevent the system from sounding and reporting by Keyfob Press disarm Keypad Enter pincode follow by pressing disarm Control panel Enter pincode and press OK Stop Exit Delay During the exit countdown user can prevent the system from arming by Keyfob Press disarm Keypad ...

Page 8: ...the entry delay time expires the control panel will emit a long beep The LCD will display Part Arm 1 2 3 and the system is now in the part arm mode Lone Occupant The Lone Occupant mode allows a user to deactivate bypass any sensors so that it will not trigger the Alarm for one time only operation This feature is ideal when the occupant plans to stay in one area for a prolonged length of time and t...

Page 9: ...anel press OK and the system will prompt you for your pincode Press ok and the following display will be shown force arm OK Press OK to confirm The defined timer starts to Count Down Please note for Lone occupant mode it will be 300 seconds time to exit 30 sec When the Exit Delay timer expires the Control Panel will emit a long beep and the system is now in the designated Arm Mode Arming with door...

Page 10: ...ish to arm the system while ignoring the supervisory fault follow the steps described in the Force Arming section for operation Set Time Date This option allows you to set the system time and date You can also define your local daylight saving hour time date year daylight Time Use the Up and down key to define the 24hr time Press OK to confirm the setting Date Use the Up and down key to define the...

Page 11: ...ht 1 o clock 2 o clock Please now proceed to set the End month to complete the setting Bypass Sensors As a one time operation the user can bypass any learnt sensor so that it is omitted from the system Choose from a list of sensors to bypass PIR Z01 DC z02 dc z03 DC z03 bypass OK The selected device will now be marked with an PIR Z01 DC z02 dc z03 This is only valid when the user stays in the user...

Page 12: ...e GSM This feature is only shown if GSM GPRS module is available GSM signal gsm reset GSM Signal Upon selection it will display the RSSI value Signal strength 0 is the weakest while 9 is the strongest If there are no network coverage the screen will display RSSI Unknown A weak signal may result in failure to dial out and to receive incoming calls GSM Reset User can reset the GSM GPRS module by sel...

Page 13: ...ster user Defined through User attribute log into the user menu user setting engineer access alarm clock panel key led status led answer machine front tamper desk tamper User Setting It allows you to set up user code use once code and user attributes user code use once code user attribute User Code It allows you to set up 32 sets of user codes 1 2 13 ...

Page 14: ...1 representing if the user is set to have access to Part Arm 1 default enable 2 representing if the user is set to have access to Part Arm 2 default enable 3 representing if the user is set to have access to Part Arm 3 default enable 4 representing if the user is set to have access to the Lone Occupant mode default enable T representing if the user is set to have access to Time Setting default ena...

Page 15: ...ng If a schedule is defined using the PC software Schedule option will be shown Alarm Tone User can select the volume and the sound clip ring tone 10 clips Alarm via phone You can set the alarm to call a phone number at the designated time Enter the phone number when prompt Panel Key LED This option controls the panel s key LED backlight always on touch on Always On The Panel s Key LED is always o...

Page 16: ...nel is tamper protected This option allows the user to enable or disable this tamper function Desk Tamper The control panel has a built in tilt sensor to protect against unauthorised removal movement This feature can be enable or disable accordingly 16 ...

Page 17: ... out Call Engineer Your engineer may have preset their phone number on the system for easy access Press and hold up button for 5 seconds The pre set PSTN phone number or GSM GPRS phone number will be displayed Nothing will be shown if no numbers set If both PSTN and GPRS number are set user will be required to choose one Press OK to start dialing Remote Command The control panel can be controlled ...

Page 18: ...rom above the confirmation message will be Confirm Jke 11234 11 00 2 If you do not wish to receive confirmation SMS from the control panel please skip the 00 at the end when sending remote command For example Jke_11234_11 3 If Area 2 had not been enabled please skip the digit in front of the user pincode For example Jke_1234_11_00 4 For a full list of available commands please see the SMS Command ...

Page 19: ...RS User can issue remote commands to the control panel via voice calling Either through PSTN or GSM GPRS phone line To enable this function the Answer machine must first be enabled under the Master setup menu 1 Use a telephone mobile phone to call the control panel s number 2 Wait until the panel picks up the call 3 You will need to enter the pincode then example 123400 BEFORE the answer machine v...

Page 20: ...ximum number of messages is 20 and once it is full the oldest message will be deleted and replace with new recording Alarm reporting After the occurrence of an alarm event the system will report the event through PSTN and GSMP GPRS phone line if available The reporting sequence 1 SMS reporting for ARC 2 Digital reporting for ARC Contact ID 3 SMS reporting to user s phone 4 Voice reporting to user ...

Page 21: ......

Page 22: ...rvices on 01902 364647 who will give you the name of an expert and confirm what you need to do to make a claim under this guarantee Please do not carry out any repairs without our authority or by using an unauthorised expert Any repairs or other works carried out without our authorization or by using an unauthorized expert will not be covered under this guarantee This guarantee is non transferrabl...

Reviews: