![Yale SLE 3 Operation Manual Download Page 32](http://html1.mh-extra.com/html/yale/sle-3/sle-3_operation-manual_3104548032.webp)
8
Technical data
32
09.2019
ba
-o
.4
.1
.3
-en
-2
.2
-y
Impact, vibrations
EN 60068-2-27 10 g
–
11 ms
EN 60068-2-6 3 mm at 2...9 Hz; 0.5 g at 9...200 Hz
EMC
EN 61000-6-2-7 Immunity for devices intended to perform functions in safety-
related systems (functional safety) at industrial sites
EN 61000-6-3 Emission standard for residential, commercial and light-industrial
environments
Temperature range operation
-20 °C ... +55 °C (standard)
-20 °C ... +70 °C (optional)
Storage
-40 °C ... +80 °C
Dimensions
100 × 110 × 75 mm (W × H × D)
Protection
IP20, EN 60529
Connection terminals
30 box terminals with captive plus-minus screws
Per box terminal: 1 × 4 mm
2
solid or 1 × 2.5 mm
2
stranded wire with wire ferrules
or 2 × 1.5 mm
2
stranded wire, with wire ferrules
Tightening torque of the screw terminals 0.5 Nm
Attachment
Top hat rail EN 50022
Weight
0.5 kg
Mounting position
Horizontal, vertical
Maximum cable length
- Digital control signals
- Temperature inputs
- Sensor inputs (shielded)
100 m
50 m
5 m
Safety parameter values per ISO 13849-1
SLE 3
Performance level
d
PFH
5.28 E-07
MTTFd
100 years
DC
84 %
Category
2
Response time
850 ms
Requirements for sensors:
Performance level
c
PFH
< 1.08 E-06
MTTFd
>= 100 years
Category
1
Requirements for the contactor:
Performance level
c
PFH
< 1.32 E-06
B10d
> 1,300,000 (assumed cycles/year: 150,000)
Category
1