background image

Lockmaster AutoEngage - 

Fire Door Routing Prep

Classic multipoint lock - YAS1-3500-FD

The incorrect routing can lead to a number of operation and performance 
issues. 

Handle / Cylinder Pull

Routing

Lock Routing

Keep Routing

Prep rev. 4 - March 2022

The Lockmaster AutoEngage has been designed for use on independently accredited Fire Doors. Please ensure that you have the correct test 
evidence in place before using this product as part of a Fire Door assembly.

Yale Door and Window Solutions does not hold or provide Fire Door test evidence for this product. The responsibility for ensuring its compliance is 
solely down to the door set manufacturer.

16mm = 35 b/s

26mm = 45 b/s

35mm = 35 b/s

45mm = 45 b/s

54mm = 35 b/s

64mm = 45 b/s

60mm = 35 b/s

70mm = 45 b/s

Ø 8 (x2)

Ø 20

Ø 20

38

36

92

101

22

TO CENTRE OF 

CASE

20

147

20

228

750

738.5

17

74

2200

20

147

138

47.5

2.5

11.5

22

90

69

3

95

18

16

77

91

70

1

22

90

25

2

25

2

25

2

Summary of Contents for Lockmaster AutoEngage

Page 1: ...Lockmaster AutoEngage Installation and adjustment guide...

Page 2: ...and adjust the packing below the frame on the lock side to achieve a consistent gap at the top of the door between the leaf and frame As a guide align the gearbox latch to the centre of the latch cas...

Page 3: ...to the frame is achieved on all security latches Figure five 3 5mm Adjustable latch casting Adjustable cam 4mm hex key Part code AS3KP C06 latch keep end packer Screw recommendations Yale recommends...

Page 4: ...uting Keep Routing Prep rev 8 March 2022 Note If a 16mm faceplate lock is being used without a carrier please refer the Yale Technical Services team 16mm 35 b s 26mm 45 b s 35mm 35 b s 45mm 45 b s 54m...

Page 5: ...Routing Prep rev 8 March 2022 Note If a 16mm faceplate lock is being used without a carrier please refer the Yale Technical Services team 16mm 35 b s 26mm 45 b s 35mm 35 b s 45mm 45 b s 54mm 35 b s 6...

Page 6: ...hat you have the correct test evidence in place before using this product as part of a Fire Door assembly Yale Door and Window Solutions does not hold or provide Fire Door test evidence for this produ...

Page 7: ...have the correct test evidence in place before using this product as part of a Fire Door assembly Yale Door and Window Solutions does not hold or provide Fire Door test evidence for this product The r...

Page 8: ...be required please route as per the illustrations below for either a 16mm or 20mm faceplate lock variant Figure six Technical Illustration 38mm CRS 8mm CRS A A 2 Thru holes to accomodate M6 fixing scr...

Page 9: ...ent On the lock side there is a narrow air gap Adjust the hinges to give a 3 5mm gap between the keep and lock faceplate Security latches not deadlocking Wide air gap to the lock side Adjust the hinge...