background image

21

feature to be switched on and off.
• Warning on is the factory default.

Time

The Control Panel uses a 24 hour clock.  The time 
is set by using the 

pq

 keys and confirmed by 

pressing the 

3

 key.

Date

The day and month are set by using the 

pq

 keys 

and confirmed by pressing the 

3

 key.

Supervision

Enable or disable supervision detection on the 
Control Panel. PIR Motion Detector, Door/Window 
Contact, Smoke Detector and External Siren can 
be monitored for outage using this feature. With 
the exception of the Smoke Detector (which is 
always on), the other three accessories need to 
have supervision enabled on board to facilitate this 
feature. 
• Default setting is Disable (recommended).

Final Door

If this is turned On, a system counting down under 
the full arm mode will immediately arm when user 
exit and triggers the Door/Window Contact’s close 
position (Applies to door contact with “entry” 
attribute only). 
• Final Door Off is the factory default.

Tel. Settings

This menu allows you to program up to 3 telephone 
numbers, record an address message and place 
test calls. The following items can be selected.
• Tel. Numbers
• Rec. Address
• Test Report

Tel. Numbers

This menu has a list of 3 telephone numbers.  These 
numbers are dialed in order, a maximum of 20 digits 
per number can be stored.  Only one number is 
required to enable the Control Panel to report over 
the telephone line.

1.

  Use the 

pq

 keys to select a number from the 

list.

2.

   Press 

3

 to confirm. If there was a number already 

stored then you will be asked to change the 
number, if the slot was empty you will be asked to 
enter a new number, confirm by pressing 

3

.

3.

  Enter your phone number and confirm by  

pressing 

3

. Press “Up arrow” key for 

key (insert 

3 seconds time gap, useful for switchboard) and 
“Down arrow” key for the # key.

• Errors can be corrected by pressing 

P

 to 

backspace, pressing 

P

 repeatedly will take 

you back the telephone number list. Telephone 
numbers can be deleted in the same manner.

Rec. Address

This menu allows the recording of your address.  
The maximum length of message is 10 seconds 
which is ample for most messages, when recording 
remember to speak clearly and slowly into the 
microphone.

1.

   Press 

3

 and you will be either asked to record a 

new message or change an old one.

2.

  Press  

3

 again and follow the on screen 

instructions.  When you finish recording remember 
to press 

to stop recording. If you go over the 

10 second recording time (indicated by a beep) 
just repeat the recording procedure again taking 
care not to go over the 10 second time limit. The 
recording is complete.

Test report

This menu allows you to test the telephone reporting 
feature. 
• Please check with the call recipients before making 

a test call.

• Ensure that the phone cord is connected.

1.

 Select Test report and press 

3

2.

  A list of numbers will be displayed, select the 

number you want to test and press 

3

.

3.

  

The Control Panel will now display call progress.

•   The address message and pre-recorded 

emergency, burglar and acknowledgement 
request messages will be played in a loop for 85 
seconds.

•   The test can be cancelled at any time by either 

pressing the 

P

 button or the call recipient 

pressing “9” on their phone to acknowledge the 
call. If a radio DECT or mobile phone is used, 
remember to press 9 repeatedly until the call 
closes.

•   Check that the call has been successfully 

received.

21

Summary of Contents for IA-210

Page 1: ...1 Intruder Alarm Kit IA 210 IA 220 IA 230 The smarter way to protect your home Quick Start Guide Full User Manual ...

Page 2: ...Please visit the registration web page and insert the product details Register your product to get products news and updates if you need extra accessories or spare parts please visit yale co uk 1 Installation Service Want us to install this product Why not call Yale Smart Security Partners and let a professional installer take care of the rest Choose your package online at www yalestore co uk inst...

Page 3: ... in the following pages See your box for kit content Unpack your kit Plan your system Panel set up Device installation Activating devices Device installation Testing device signal strength Device installation Install the devices in the desired location Using the system Each kit contains different components see your box for kit content Index 3 Page 4 Page 6 Page 7 Page 9 Page 10 Page 11 Page 15 ...

Page 4: ...ctivate your alarm immediately even when the system is disarmed How to Disarm 3sec Motion Detector Pet AC PETPIR Available with IA 230 Kit or as accessory How to Full Arm How to Part Arm Max 27 kg All the devices in this kit are pre paired for easy installation If you are adding more devices purchased separately to this kit you will need to pair these into the system separately see page 18 1 Unpac...

Page 5: ...ed with either internal or external security tamper mechanism please make sure the tamper spring is fully compressed when you install the devices 05 Keyfob AC KF Available with IA 230 Kit or as accessory Contactless Tag AC RFIDTAG 1 5 ...

Page 6: ... not point directly at a source of heat eg fires or boilers facing a window or a door protected by a Door Window contact Avoid installing directly above radiators 4 If you have Pets that may climb on furniture avoid using PET PIR Motion detectors as this can cause false alarms Instead replace with additional Door Window Contacts 5 Mount the External siren as high as possible on an external wall Pl...

Page 7: ...7 1 2 4 5 07 Standard PSTN phone landline socket The wall mounting holder should be always inserted because the panel has got a tamper switch 3 3 Panel set up O n O ff a b c a b c d 3 Panel Set up 7 ...

Page 8: ...ons please visit the product page and download the full advanced manual for further details When set up is complete select Exit set up Press to confirm Press PIN code to exit the set up process If you wish to repeat the process select Repeat set up Press to confirm Wecome to your Yale Alarm System Yale Intruder Alarm Initial Menu Exit set up Repeat set up Continue installation www yale co uk Panel...

Page 9: ... page 18 Device Installation Test device signal 10 PIR Zone03 E T 9 PIR 1 If signal strength is below 2 please try to move the device to a different location and repeat connection test After all devices have been tested in the desired location Press to exit Test mode Press or button and enter your PIN code to access the main menu Scroll down using button and select Test and press Select Device and...

Page 10: ... location and repeat connection test After all devices have been tested in the desired location Press to exit Test mode Press or button and enter your PIN code to access the main menu Scroll down using button and select Test and press Select Device and press to enter the panel into learning mode Press button to test connection 5 8 9 5 Device Installation Testing Device Signal Strength 10 ...

Page 11: ...11 1 a b c 1 8m 2 1m d 2 a a b 3 4 5 6 11 Ø 5mm 6 Device installation Install the device in the desired location 6 Device Installation Install the devices in the desired location 11 ...

Page 12: ...2 1 3 5 6 7 2 4 a b max 10mm or 12 6 Device installation Install the device in the desired location Clean the mounting surface before application with a suitable degreasing agent 6 Device Installation 12 ...

Page 13: ...13 13 6 1 3 4 5 2 6 a a a b b b c d Ø 5mm Device installation Install the device in the desired location 13 ...

Page 14: ...14 1 a a d b b c 2 3 4 5 6 14 Ø 5mm 6 Device installation Install the device in the desired location 6 Device Installation 14 ...

Page 15: ... is possible to set an entry delay timer to allow you to enter the property and disarm your system before the alarm is triggered download the advanced manual for full instructions When the alarm is triggered the system will auto dial pre programmed telephone numbers Please download the full user manual to find how to set up more telephone numbers use the telecommunication features and tailor your ...

Page 16: ...ll sound during a screen self test This allows you to test the system without causing an alarm To test the Control Panel is receiving a signal do one of the following on each accessory that you want to test 1 Key Pad Press button 8 and 9 together on the Key Pad 2 For all other Accessories Press the test learn button on the accessories A chime will sound and the display will show you which device i...

Page 17: ...Entry 24 Hour DC only The following devices have a fixed emergency zone type Smoke Detector Key Fob Button Panic Button Key Pad 2 red buttons Zone Type List Burglar When the system is armed and a device is triggered the alarm will be activated immediately A device set to burglar will not trigger an alarm during entry or exit delay periods Home Omit A home omit device will be ignored when the syste...

Page 18: ...e P Backspace and delete The name can be erased by clearing the display by pressing X repeatedly followed by 3 4 Press 3 when completed to confirm the name and return to the device list Remove Device To delete a device choose remove device in the Edit device menu A list of all programmed devices will be shown 1 Use st keys to select the device you wish to delete and press 3 2 The selected device w...

Page 19: ...assword is used to configure the Control Panel and to disarm the system To disarm press the disarm key followed by your PIN code To enter the program menu press the st key enter a PIN code followed by 3 Up to 6 PIN codes can be stored 1 Select PIN Code then press 3 a list of 6 PIN codes will be shown occupied codes are shown with The list can be scrolled up and down using thest keys 2 Select the c...

Page 20: ... The length of the alarm can be set from 1 to 10 minutes in 1 minute increments with this setting 3 minutes is the factory default Panel Siren You can disable the Control Panel s built in siren with this setting Siren on is the factory default Jamming Det Enable or disable Jamming Interference detection on the Control Panel Confirmed by pressing the 3 key Default setting is Disable recommended KF ...

Page 21: ... to enter a new number confirm by pressing 3 3 Enter your phone number and confirm by pressing 3 Press Up arrow key for key insert 3 seconds time gap useful for switchboard and Down arrow key for the key Errors can be corrected by pressing P to backspace pressing P repeatedly will take you back the telephone number list Telephone numbers can be deleted in the same manner Rec Address This menu allo...

Page 22: ...press the disarm key followed by a PIN code on the Control Panel and Key Pad You can also tap the contactless tag on the panel to disarm The Key Fob only will only disarm the system during entry time after an entry or away entry Door Window Contact or PIR Motion Detector has been triggered 2 The Control Panel will sound a long beep The External Siren will beep twice and the strobe will flash side ...

Page 23: ...or 15 seconds before dialling the preset phone numbers After dialling the Control Panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the message by pressing 9 on their teleph...

Page 24: ...d for 1 hour after which it will automatically arm again If longer is needed to fit the Siren then simply repeat the steps above Leave the Control Panel in programming mode to stop the system responding to tampers If the Control Panel automatically times out re enter programming mode again i Enabling the system tamper After mounting the External Siren and detectors please enable the system tamper ...

Page 25: ...ollowed by the 7 key to set the Key Pad into Control Panel system mode also known as slave mode 3 The LED will now flash slowly indicating it is in test programming mode 4 Press the Panic button A key followed by the 7 key to set the Key Pad into Control Panel system 5 Quit test mode by pressing the disarm key twice The Key Pad code and mode setting has been completed The Key Pad will now use the ...

Page 26: ...y Pad into Control Panel system mode also known as slave mode 3 The LED will now flash slowly indicating it is in test programming mode 4 Press the Panic button A key followed by the 7 key to set the Key Pad into Control Panel system 5 Quit test mode by pressing the disarm key twice The Key Pad code and mode setting has been completed The Key Pad will now use the same PIN code that is set for the ...

Page 27: ...ns To check the fault log see page 25 PIR Motion Detector Battery Change When the battery is low the LED will flash when any motion is detected The batteries are changed as follows 1 Put Control Panel into programming mode to prevent a tamper alarm 2 Loosen the case screw and remove PIR from base to reveal the batteries 3 Insert 3 x new AAA alkaline batteries observing correct polarity The PIR LED...

Page 28: ...y is changed as follows 1 Put Control Panel into programming mode to prevent a tamper alarm 2 Unscrew the two Key Pad case screws and remove Key Pad back to reveal battery 3 Using a screwdriver gently lever out the old battery 4 Insert new CR2032 coin cell battrey with the side uppermost 5 Press battery into holder firmly with finger and thumb until a click is heard see picture below 6 Press a num...

Page 29: ... random fluctuations and responds to genuine motion across field of view it is less sensitive walking directly towards it PIR Motion Detector gives false alarms Check pets have no access to protected area Check that the PIR Motion Detector is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR Motion Detector is not mounted above convector heaters or pointing di...

Page 30: ...dividual fault messages will be displayed sequentially at 2 second intervals IMPORTANT Please enter the programming menu first before swapping the batteries otherwise you will trip the system tamper alarm Press the pq and enter your user PIN code followed by pressing 3 Stay in the programming menu Then disconnect the relevant accessory and replace batteries If the Control Panel times out and retur...

Page 31: ... scenario Disarm GREEN Away Arm RED Home Arm YELLOW Exit Away Arm Entry Home Arm Entry Burglar No action Instant Burglar alarm Instant Burglar alarm No action No action No action Home Omit No action Instant Burglar alarm No action No action No action No action Entry Door Chime Start Entry Timer Start Entry Timer No action No action No action Away Entry Door Chime Start Entry Time No action No acti...

Page 32: ...lier of locking solutions dedicated to satisfying end user needs for security safety and convenience PACKAGING FR An ASSAABLOY Group brand Yale Intruder Alarm v08 YaleSecurityUK YaleSecurity YaleUK Customer Service At Yale we know the importance of providing security products that are easy to install and use However should you have any questions or experience a problem with your purchase please vi...