premises before the system arms. Times can be set 
from 00 seconds (no delay) up to 70 seconds in 10 
second increments.
• 30 seconds is the factory default.
Select using the selection keys, if you want to set 
entry time for Away or Part Arm mode and press V 

3

Entry Sound

The Control Panel will beep during the entry delay 
period as an entry warning, you can switch the 
sound on and off with this setting.
• Entry sound on is the factory default.

Exit Sound

The Control Panel will beep during the exit delay 
period as an exit warning, you can switch the sound 
on and off with this setting.
• Exit sound on is the factory default.

Door Chime

Any Door/Window Contact or PIR Motion Detector 
set to entry will cause the Control Panel to chime 
when activated when the system is disarmed.  This 
is used to signal when someone has entered your 
premises. You can switch the sound on and off with 
this setting.
• Chime off is the factory default.

DC Open/Close

If this is turned On, the Control Panel will sound a 
door chime and display a fault message when user 
tries to arm the system with Door/Window Contact 
opened. 
• DC Open/Close Off is the factory default.

LCD Backlight

The Control Panel display LCD can be turned on 
Permanently or set to auto turn off after 30 seconds 
of last key pressed.
• Auto off is the factory default.

Key Tone

The Control Panel can be made to beep when a key 
is pressed. Key Tone can be selected to On or Off.
• Key Tone On is the factory default.

Ring Tone

The Control Panel can be made to beep when the 
phone is ringing, you can switch the sound on and 
off with this setting.
• Ringing off is the factory default.

Alarm Length

The Siren (both external and built-in) will sound when 
an alarm is activated. The length of the alarm can be 
set from 1 to 10 minutes in 1 minute increments with 
this setting.
• 3 minutes is the factory default.

Panel Siren

You can disable the Control Panel’s built-in siren with 
this setting.
• Siren on is the factory default.

Jamming Det

Enable or disable Jamming/Interference detection on 
the Control Panel. Confirmed by pressing the 

3

 key. 

Default setting is Disable (recommended).

KF Entry

When selected as Off, user must first trigger an entry 
sensor before the Key Fob can disable the system. 
Please select On if you which to disarm the system 
without first triggering an entry sensor. 
• KF Entry Off is the factory default.
• If the Key Fob’s panic button is triggered, the 
same Key Fob cannot be used to silence the 
External Siren.

Tamper Alarm

If set to Away Arm only, it will trigger the alarm when 
tamper is active under Away Arm mode (also known 
as Full Arm). It will only give a fault LED indication in 
all other mode. If set to Normal, a tamper condition 
will always triggers a burglar alarm under Disarm, 
Home Arm and Away Arm mode. 
• Away Arm Only is the factory default.

Mobility CHK (for elderly or infirm)

If there is no movement around the house for a 
preset period of time (from home omit sensors under 
Part Arm and all sensors under disarm mode), an 
emergency alarm will be activated and reported over 
the telephone line. Any key pressed on the Control 
Panel and entry sensor triggering will reset the 
countdown timer.  The monitoring can be disabled 
or set at 4, 8 and 12 hour.
• Disable is the factory default.

Siren Delay

This setting allows a delay before the Control Panel 
and External Sirens are activated. You might want to 
use this if you do not want the Control Panel to draw 
attention to itself during an alarm, to give it time to 
dial out on the telephone line. The delay can be set 
from Disable (no delay) to 10 minutes in increments 
of 1 minute.
• Disable is the factory default.

20

Summary of Contents for IA-210

Page 1: ...1 Intruder Alarm Kit IA 210 IA 220 IA 230 The smarter way to protect your home Quick Start Guide Full User Manual ...

Page 2: ...Please visit the registration web page and insert the product details Register your product to get products news and updates if you need extra accessories or spare parts please visit yale co uk 1 Installation Service Want us to install this product Why not call Yale Smart Security Partners and let a professional installer take care of the rest Choose your package online at www yalestore co uk inst...

Page 3: ... in the following pages See your box for kit content Unpack your kit Plan your system Panel set up Device installation Activating devices Device installation Testing device signal strength Device installation Install the devices in the desired location Using the system Each kit contains different components see your box for kit content Index 3 Page 4 Page 6 Page 7 Page 9 Page 10 Page 11 Page 15 ...

Page 4: ...ctivate your alarm immediately even when the system is disarmed How to Disarm 3sec Motion Detector Pet AC PETPIR Available with IA 230 Kit or as accessory How to Full Arm How to Part Arm Max 27 kg All the devices in this kit are pre paired for easy installation If you are adding more devices purchased separately to this kit you will need to pair these into the system separately see page 18 1 Unpac...

Page 5: ...ed with either internal or external security tamper mechanism please make sure the tamper spring is fully compressed when you install the devices 05 Keyfob AC KF Available with IA 230 Kit or as accessory Contactless Tag AC RFIDTAG 1 5 ...

Page 6: ... not point directly at a source of heat eg fires or boilers facing a window or a door protected by a Door Window contact Avoid installing directly above radiators 4 If you have Pets that may climb on furniture avoid using PET PIR Motion detectors as this can cause false alarms Instead replace with additional Door Window Contacts 5 Mount the External siren as high as possible on an external wall Pl...

Page 7: ...7 1 2 4 5 07 Standard PSTN phone landline socket The wall mounting holder should be always inserted because the panel has got a tamper switch 3 3 Panel set up O n O ff a b c a b c d 3 Panel Set up 7 ...

Page 8: ...ons please visit the product page and download the full advanced manual for further details When set up is complete select Exit set up Press to confirm Press PIN code to exit the set up process If you wish to repeat the process select Repeat set up Press to confirm Wecome to your Yale Alarm System Yale Intruder Alarm Initial Menu Exit set up Repeat set up Continue installation www yale co uk Panel...

Page 9: ... page 18 Device Installation Test device signal 10 PIR Zone03 E T 9 PIR 1 If signal strength is below 2 please try to move the device to a different location and repeat connection test After all devices have been tested in the desired location Press to exit Test mode Press or button and enter your PIN code to access the main menu Scroll down using button and select Test and press Select Device and...

Page 10: ... location and repeat connection test After all devices have been tested in the desired location Press to exit Test mode Press or button and enter your PIN code to access the main menu Scroll down using button and select Test and press Select Device and press to enter the panel into learning mode Press button to test connection 5 8 9 5 Device Installation Testing Device Signal Strength 10 ...

Page 11: ...11 1 a b c 1 8m 2 1m d 2 a a b 3 4 5 6 11 Ø 5mm 6 Device installation Install the device in the desired location 6 Device Installation Install the devices in the desired location 11 ...

Page 12: ...2 1 3 5 6 7 2 4 a b max 10mm or 12 6 Device installation Install the device in the desired location Clean the mounting surface before application with a suitable degreasing agent 6 Device Installation 12 ...

Page 13: ...13 13 6 1 3 4 5 2 6 a a a b b b c d Ø 5mm Device installation Install the device in the desired location 13 ...

Page 14: ...14 1 a a d b b c 2 3 4 5 6 14 Ø 5mm 6 Device installation Install the device in the desired location 6 Device Installation 14 ...

Page 15: ... is possible to set an entry delay timer to allow you to enter the property and disarm your system before the alarm is triggered download the advanced manual for full instructions When the alarm is triggered the system will auto dial pre programmed telephone numbers Please download the full user manual to find how to set up more telephone numbers use the telecommunication features and tailor your ...

Page 16: ...ll sound during a screen self test This allows you to test the system without causing an alarm To test the Control Panel is receiving a signal do one of the following on each accessory that you want to test 1 Key Pad Press button 8 and 9 together on the Key Pad 2 For all other Accessories Press the test learn button on the accessories A chime will sound and the display will show you which device i...

Page 17: ...Entry 24 Hour DC only The following devices have a fixed emergency zone type Smoke Detector Key Fob Button Panic Button Key Pad 2 red buttons Zone Type List Burglar When the system is armed and a device is triggered the alarm will be activated immediately A device set to burglar will not trigger an alarm during entry or exit delay periods Home Omit A home omit device will be ignored when the syste...

Page 18: ...e P Backspace and delete The name can be erased by clearing the display by pressing X repeatedly followed by 3 4 Press 3 when completed to confirm the name and return to the device list Remove Device To delete a device choose remove device in the Edit device menu A list of all programmed devices will be shown 1 Use st keys to select the device you wish to delete and press 3 2 The selected device w...

Page 19: ...assword is used to configure the Control Panel and to disarm the system To disarm press the disarm key followed by your PIN code To enter the program menu press the st key enter a PIN code followed by 3 Up to 6 PIN codes can be stored 1 Select PIN Code then press 3 a list of 6 PIN codes will be shown occupied codes are shown with The list can be scrolled up and down using thest keys 2 Select the c...

Page 20: ... The length of the alarm can be set from 1 to 10 minutes in 1 minute increments with this setting 3 minutes is the factory default Panel Siren You can disable the Control Panel s built in siren with this setting Siren on is the factory default Jamming Det Enable or disable Jamming Interference detection on the Control Panel Confirmed by pressing the 3 key Default setting is Disable recommended KF ...

Page 21: ... to enter a new number confirm by pressing 3 3 Enter your phone number and confirm by pressing 3 Press Up arrow key for key insert 3 seconds time gap useful for switchboard and Down arrow key for the key Errors can be corrected by pressing P to backspace pressing P repeatedly will take you back the telephone number list Telephone numbers can be deleted in the same manner Rec Address This menu allo...

Page 22: ...press the disarm key followed by a PIN code on the Control Panel and Key Pad You can also tap the contactless tag on the panel to disarm The Key Fob only will only disarm the system during entry time after an entry or away entry Door Window Contact or PIR Motion Detector has been triggered 2 The Control Panel will sound a long beep The External Siren will beep twice and the strobe will flash side ...

Page 23: ...or 15 seconds before dialling the preset phone numbers After dialling the Control Panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the message by pressing 9 on their teleph...

Page 24: ...d for 1 hour after which it will automatically arm again If longer is needed to fit the Siren then simply repeat the steps above Leave the Control Panel in programming mode to stop the system responding to tampers If the Control Panel automatically times out re enter programming mode again i Enabling the system tamper After mounting the External Siren and detectors please enable the system tamper ...

Page 25: ...ollowed by the 7 key to set the Key Pad into Control Panel system mode also known as slave mode 3 The LED will now flash slowly indicating it is in test programming mode 4 Press the Panic button A key followed by the 7 key to set the Key Pad into Control Panel system 5 Quit test mode by pressing the disarm key twice The Key Pad code and mode setting has been completed The Key Pad will now use the ...

Page 26: ...y Pad into Control Panel system mode also known as slave mode 3 The LED will now flash slowly indicating it is in test programming mode 4 Press the Panic button A key followed by the 7 key to set the Key Pad into Control Panel system 5 Quit test mode by pressing the disarm key twice The Key Pad code and mode setting has been completed The Key Pad will now use the same PIN code that is set for the ...

Page 27: ...ns To check the fault log see page 25 PIR Motion Detector Battery Change When the battery is low the LED will flash when any motion is detected The batteries are changed as follows 1 Put Control Panel into programming mode to prevent a tamper alarm 2 Loosen the case screw and remove PIR from base to reveal the batteries 3 Insert 3 x new AAA alkaline batteries observing correct polarity The PIR LED...

Page 28: ...y is changed as follows 1 Put Control Panel into programming mode to prevent a tamper alarm 2 Unscrew the two Key Pad case screws and remove Key Pad back to reveal battery 3 Using a screwdriver gently lever out the old battery 4 Insert new CR2032 coin cell battrey with the side uppermost 5 Press battery into holder firmly with finger and thumb until a click is heard see picture below 6 Press a num...

Page 29: ... random fluctuations and responds to genuine motion across field of view it is less sensitive walking directly towards it PIR Motion Detector gives false alarms Check pets have no access to protected area Check that the PIR Motion Detector is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR Motion Detector is not mounted above convector heaters or pointing di...

Page 30: ...dividual fault messages will be displayed sequentially at 2 second intervals IMPORTANT Please enter the programming menu first before swapping the batteries otherwise you will trip the system tamper alarm Press the pq and enter your user PIN code followed by pressing 3 Stay in the programming menu Then disconnect the relevant accessory and replace batteries If the Control Panel times out and retur...

Page 31: ... scenario Disarm GREEN Away Arm RED Home Arm YELLOW Exit Away Arm Entry Home Arm Entry Burglar No action Instant Burglar alarm Instant Burglar alarm No action No action No action Home Omit No action Instant Burglar alarm No action No action No action No action Entry Door Chime Start Entry Timer Start Entry Timer No action No action No action Away Entry Door Chime Start Entry Time No action No acti...

Page 32: ...lier of locking solutions dedicated to satisfying end user needs for security safety and convenience PACKAGING FR An ASSAABLOY Group brand Yale Intruder Alarm v08 YaleSecurityUK YaleSecurity YaleUK Customer Service At Yale we know the importance of providing security products that are easy to install and use However should you have any questions or experience a problem with your purchase please vi...

Reviews: