Yale HSA3400 Installation, Programming, Operating Download Page 19

19

Trouble shooting

Siren

Siren does not respond to keypad

• Keypad low battery or bad connection. Check

battery connections and polarity, if OK replace
battery with alkaline equivalent.

• Siren batteries are completely exhausted.

Check siren batteries by removing siren cover, if
there is no tamper alarm when removed,
replace batteries with new alkaline equivalents.

• Keypad not learnt-in. If siren produces a tamper

alarm when the cover is removed, and keypad
is OK, learn-in the keypad. 

Siren produces a 3 second alarm when disarmed

• There has been a previous alarm and there

might be an intruder still in the premises.

Siren produces a series of pips when armed or
disarmed

• The siren has low batteries. Check that the

siren produces a series of pips when arming
and disarming, indicating low batteries. Change
batteries with new alkaline replacements. 

• The siren tamper switch has been disturbed.

Check that the siren produces a series of pips
only when arming, indicating a tamper
condition. Check that the siren cover is firmly
secured and the tamper switch plunger is in
contact with the wall. If not use suitable
packing material to fill gap. 

Siren produces an interrupted tone when
sounding an alarm

• The siren has low batteries. Change batteries

with new alkaline replacements. 

Keypad

Keypad produces a beep every 30 seconds

• The tamper switch at the rear of the keypad is

open. Ensure the switch closes when the
keypad is mounted.

PIR

PIR does not respond to movement

• Previous movement has triggered the PIR sleep

timer is preventing subsequent movement
detection. Arm system and vacate protected
room for at least 1.5 minutes before testing.

PIR is slow to respond 

• This is normal, the PIR has sophisticated false

alarm filtering that will filter out random
fluctuations and responds to genuine
movement across field of view, it is less
sensitive walking directly towards it.

PIR gives false alarms

• Check pets have no access to protected area. 
• Check that PIR is not pointed at sources of heat

or moving objects, e.g. fluttering curtains.

• Check that PIR is not mounted above convector

heaters or pointing directly at windows.

PIR LED flashes when jumper is in normal position

• Batteries are low or the tamper switch is

disturbed. Check that the tamper switch spring
is making contact with base. If the tamper
switch is OK, change batteries with new
alkaline replacements.

PIR does not respond to movement when jumper
is in test position

• Batteries are completely exhausted. Change

batteries with new alkaline replacements, LED
will flash for 30 seconds while components
initialise.

Door contact

Door contact LED flashes when jumper is in
normal position

• Batteries are low or the tamper switch is

disturbed. Check that the tamper switch spring
is making contact with the mounting surface. If
the tamper switch is OK, change batteries with
new alkaline replacements.

Door contact does not respond to door opening
when jumper is in test position

• Batteries are completely exhausted. Change

batteries with new alkaline replacements 

• The magnet is too far away from the door

contact. Check that the gap between door

www.ukpanels.com

Summary of Contents for HSA3400

Page 1: ...HSA3400 Keypad alarm system Installation Programming Operating Keep in a handy place for reference and for future maintenance Helpline 01902 635998 www ukpanels com ...

Page 2: ...nauthorised tampering with the system will result in an alarm This feature can be turned off by the user when a battery change is required Entry Exit feature The HSA3400 has a 20 second entry exit time This feature allows you time to leave the home when arming the system Upon entering the feature allows time to disarm the system without causing an alarm Take care of your safety Display extreme cau...

Page 3: ...eypad remote control 2 x Passive infrared PIR detectors 2 x Door Window contacts 2 x Door Window contact magnets 4 x 1 5V AAA alkaline cells 6 x 1 5V AA alkaline cells 3 x 1 5V AAA alkaline cells 4 x 1 5V D alkaline cells 2 x large adhesive pads 2 x small adhesive pads 4 x small wall plugs 12 x medium wall plugs 4 x large wall plugs 4 x 4mm x 30mm cross head fixing screws 12 x 3 5mm x 16mm cross h...

Page 4: ... from reaching detectors Help button accessory The help button provides extra protection for you and your family When help is needed the button can activate your alarm immediately even when the system is disarmed Mount on bedroom wall or by the front door Not clearly visible to an intruder Easily accessible Out of reach of children Not outdoors PIR movement detectors Mount in a position such that ...

Page 5: ...t door The other door window contact can be used to protect another entry point such as a rear door Mount as high as possible Do not aim a PIR at this door or window Siren Choose a position on an external wall where the siren would be most prominent Mount as high as possible out of easy reach Keypad remote control The keypad should be sited next to the main point of entry exit so that the system c...

Page 6: ...grammed on a table top before locating and mounting them 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren tamper switch unnecessarily 1 Remove the cover by unscrewing the single screw located at the bottom 2 Remove the covers of the two internal compartments 3 Insert the four D batteries as shown There is a slight pause while the unit initialises The siren wil...

Page 7: ...the jumper switch inside do not move have no function on this model Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace battery cover Switch to on Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as sho...

Page 8: ...keypad face downwards after programming to avoid accidental operation of the tamper switch The siren is programmed by the use of jumper switches in the left hand compartment Ensure all jumpers are in the on position before starting 1 Lift off jumper number 1 and park it The siren will beep and flash The siren is now in learn mode 2 Learn in the keypad by entering 0000 then press TEST The Tx LED wi...

Page 9: ...Siren activation time Siren activation time Learning in mode leave on Strobe activation mode Tamper alarm If the siren detects a tamper condition it will activate the siren for the programmed period If the tamper condition persists the siren will sound a series of five pips either every time the system is armed or when the tamper is enabled to indicate a fault Previous alarm warning If there has b...

Page 10: ...hown 3 Fix the siren cover with the securing screw Mounting the keypad 1 Ensure system tamper is disabled Repeat the steps to disable the system tamper if necessary 2 Choose a suitable location as described in Location planning usually next to main entry exit point 3 On the rear plate of the keypad break through the four knockouts where the plastic is thinner 4 Using the holes as a template drill ...

Page 11: ...test 1 Ensure that the system tamper is disabled 2 Hold the detector in the desired location and press the learnt test button siren should respond with a single beep 3 When you are satisfied that the detectors work in your chosen locations proceed with the installation as described below If the siren does not respond the location may be out of range try alternative locations until reliable radio c...

Page 12: ...s detected 1 Ensure the system tamper is disabled repeat steps to extend the tamper disable time a further hour if necessary 2 Screw the rear case to the wall using the appropriate knockouts as described in Mounting methods The case has angled back edges for neat corner mounting If mounting in a corner take care not to bend the rear case Screw the PIR front on 3 Walk around the protected area noti...

Page 13: ...t time System tampers will be active during the exit time Disarming the system After entering the premises disarm the system by entering your PIN code and press OFF The siren will beep twice and flash Upon entering the premises the first detecter activated usually a door window contact on the main point of entry will cause the 20 second entry time to start During the entry time any detector activa...

Page 14: ...learn mode and disable enable the system tamper Please note that the Home feature is not used with the HSA3400 system Programming Learn in the keyfob as follows 1 Enter learn mode as described 2 Press the Arm button ensure keyfob is switched on The keyfob LED will light and the siren will beep to confirm 3 Exit learn mode as described Arming and disarming The system is armed by pressing the ARM bu...

Page 15: ...ng the built in siren lighting the LED and sounding the external siren The smoke detector will produce a warning beep and the LED will flash every 30 seconds if the batteries are near exhaustion The learn test button can be used to test the smoke detector The detector will sound a two tone confirmation and the siren will beep Please ensure that you test smoke detectors regularly Adding further PIR...

Page 16: ...termine if your siren is sounding a tamper warning or a low battery warning by arming and disarming the system If the siren produces 5 pips when the system is armed and disarmed the batteries are low If the siren produces 5 pips only when the system is armed the tamper switch has been disturbed 1 Disable the system tamper When changing batteries allow 1 minute between taking out the old batteries ...

Page 17: ...17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 www ukpanels com ...

Page 18: ...Movement detection range 15m 110 Door window contact Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 3V 2 x AAA alkaline cells 3 years typical domestic service life Smoke detector Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 6V 4 x AAA alkaline cells 3 years typical domestic service life Keyfob remote control Radio Microprocessor controlled 433 92MHz ...

Page 19: ...ovement Previous movement has triggered the PIR sleep timer is preventing subsequent movement detection Arm system and vacate protected room for at least 1 5 minutes before testing PIR is slow to respond This is normal the PIR has sophisticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view it is less sensitive walking directly ...

Page 20: ... If any of the devices beep or flash they have either been tampered with See trouble shooting page 19 or require a new battery See how to change a battery page 16 www yale co uk E mail info yaleuk com Security Products UK Ltd Wood Street Willenhall West Midlands WV13 1LA Yale is a registered trademark E2 11 03 www ukpanels com ...

Reviews: