Copyright ©2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For technical support contact Yale
®
at 800.438.1951 x5033 or [email protected]
20
Delayed Egress
Installation Instructions
7100, 7200 Series Exit Device
80-9470-0162-000 10/20
14
Non-ElectroLynx Door Prep
Figure 8
Refer to Figure 8 for non-ElectroLynx Door preparation.
NOTE:
•
Do not scale drawing.
•
Dimensions are in inches (") and millimeters (mm).
•
LHR H.M. opening shown. Details are typical for all opening materials (both hands).
•
This preparation is an addition to preparation shown on device template.
•
See device template to locate centerline.
•
Shields for wiring access recommended for insulated and composite doors.
•
Locate and prepare wiring access holes when installing device.
Vertical
Reference
Horizontal
Reference
Hinge Edge Detail
INSIDE FACE OF DOOR
Clear Channel Access
Required for Wire
Connection
Hinge
1" (25mm) Dia.
(Wiring Access)
Horizontal Reference
Device Center line
(See Note 5)
Exit De vice End Clamp Mounting
Holes (For reference only)
HINGE EDGE DETAIL
Hinge Edge
Of Door
5/16" Ref
(8mm)
5/8" Ref
(16mm)
A
1-1/4" Re f
(32mm)
Exit Device
7200 Series
7100 Series
Dim. A
1-11/16" (43mm)
2-5/16" (59mm)
Conducting Hinge or
Approved Power Transfer
(made by other manufacturers)