50 Series Parallel Arm Installation (Right Hand Shown) cont.

6. Remove arm and attach as shown.

7. Open latch and sweep valves.

Do not completely 

open valves. Valves 

will leak.

Arm under tension. 

Keep fingers away 

from moving parts.

8. Connect arms and install forearm screw.

1st

2nd

Left Hand

Door

or

Right Hand

Door

Flat

Flat

RH: Position flat at R

LH: Position flat at L

1st

2nd

9. Preload spring and tighten forearm screw.

1-1/2

(38)

1st

2nd

3rd

By hand, rotate 

arm elbow to 

be 1-1/2" from 

door face.

Rotating arm 

preloads closer 

spring power.

3rd

The 

50 Series Non Hold Open Closer - Parallel Arm Mount

 has now been installed. 

🛑

 Go to page 2 for closer adjustments and decorative cap or cover installation. 