Yale 50 Series Installation Instructions Manual Download Page 4

80-9350-2531-010  Rev 2  02/23

Copyright © 2016, 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the 
express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

4

50 Series

 Non-Hold Open Closer

L

Y

S

Z

R

x2

or

2. Mount closer to frame.

x4

or

The 

50 Series Non Hold Open Closer - Top Jamb Mount

 has now been installed. 

🛑

 Go to page 2 for closer adjustments and decorative cap or cover installation. 

RH and LH:  

Position flat at S

3. Choose arm placement in shoe and install separate arms.

4. Connect arms and install 

forearm screw.

5. Preload spring and tighten forearm screw.

1st

2nd

Rotate elbow until 

Connecting Rod is 

perpendicular to frame.

Rotating arm preloads 

closer spring power.

1st

2nd

50 Series Top Jamb Arm Installation (Right Hand Shown)

1. Prepare door and frame.

Opening

Dimension “A”

to 100°

7-1/2 (191)

101° to 120°

6 (152)

*

121° to 180°

3-1/2 (89)

*

Door/Wall/Hardware/Jamb conditions permitting

9-1/16 

(230)

3/4 

(19)

Top of 

Door

1-1/2 

(38)

1-3/4 

(44)

(152)

1/2 

(13)

A

CL

A longer connecting rod 

is required for reveals 

greater than 3" (76mm)

Reveal

or

+

 7-1/2% 

Stronger

 7-1/2% 

Weaker

or

Approved 2023-02-24