Yale 50 Series Installation Instructions Manual Download Page 5

80-9350-2531-010  Rev 2  02/23

Copyright © 2016, 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permis-
sion of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

5

50 Series

 Non-Hold Open Closer

2. Close latch and sweep valves.

3. Install soffit plate and mount closer.

4. Remove arm shoe and install forearm to 

plate.

5. Place main arm on closer spindle and rotate

x4

or

x4

or

IMPORTANT

50 Series Parallel Arm Installation (Right Hand Shown)

1. Prepare door and frame.

9-1/16 

(230)

3/4 

(19)

Top of 

Door

1-1/2 

(38)

3-1/4 

(83)

(178)

1/2 

(13)

1/2 

(13)

Hole for 214 Plate 

only

(102)

7/16 

(11)

2-1/8 

(54)

2-3/4 

(70)

(50)

3/8 

(10)

Frame

A

CL

B

C

Door 

Opening

Dimension 

“A”

Dimension 

“B”

Dimension 

“C”

to 100°

9-1/4 (235)

7-5/8 (194)

8-5/8 (219)

101° to 130°

7-3/4 (197)

6-1/8 (156)

7-1/8 (181)

*

131° to 180°

5-3/4 (146)

4-1/8 (105)

5-1/8 (130)

*

Door/Wall/Hardware/Jamb conditions permitting

1st

2nd

Approved 2023-02-24

Reviews: