Yaesu VXR-9000 Operating Manual Download Page 6

VXR-9000 FM R

EPEATER

 O

PERATING

 M

ANUAL

T

WO

 T

ONE

 D

EC

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Two Tone Dec” to turn the 2-Tone Decoder
“On” or “Off” (toggle).

CW ID S

INGLE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “CW ID Single” to send the station callsign,
via Morse Code, once. Programming of the callsign is
performed by your VERTEX STANDARD dealer.

CW M

ESSAGE

 1 - CW M

ESSAGE

 8

Press (or press and hold in for one second) the 

PF

 key

assigned to “CW Message 1 - 8” to send a pre-pro-
grammed Morse Code message on the transmitted sig-
nal. Programming of the message(s) is performed by
your VERTEX STANDARD dealer.

DC P

OWER

 S

AVE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “DC Power Save” to turn the DC Power
Save feature “On” or “Off” (toggle).

When DC Power Save feature is set to “ON,” activate
the various power save feature (determined from your
VERTEX STANDARD dealer) while the repeater oper-
ates from the Backup Power Source.

E

NCRYPTION

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Encryption” to turn off the Optional En-
cryption Unit temporarily.

E

NCRYPTION

 C

ODE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Encryption Code” to select the Encryption
Code (determined from your VERTEX STANDARD
dealer; require the 

FVP-35

 Rolling Code Encryption

Unit).

K

EY

 L

OCK

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Key Lock” to lock the repeater’s front panel
keys (except “Key Lock” key); this feature can be en-
abled to prevent repeater settings from being disturbed.

L

OCAL

 PTT

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Local PTT” to enable (“On”) or disable
(“Off”) operation using a 

PTT

 switch connected to the

front panel’s Microphone Jack.

M

ONITOR

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Monitor” to cancel CTCSS and DCS squelch
decoding, so as to enable reception of signals present on
the channel that do not contain a matching CTCSS tone
or DCS code.

M

ONITOR

 M

This function provides to “Monitor” to cancel CTCSS
and DCS squelch decoding, so long as the 

PF

 key as-

signed to “Monitor M” is pressed and held in.

M

ULTI

 T

ONE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Multi Tone” to switch the Tone Table be-
tween “Main” and “Sub.”

P

ANEL

 I

NDICATOR

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Panel Indicator” to turn the Front Panel’s
Illumination “On” or “Off” (toggle).

R

EMOTE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Remote” to toggle the operating mode be-
tween the “

Remote

” mode and “

Local

” mode.

When the “

Remote

” mode is selected, the repeater op-

erates according to the control instructions received
from the external device (connected to the 

ACC

 jack on

the rear panel). While in the “

Local

” mode, the repeater

operates from the front panel’s 

PF

 keys.

R

EPEAT

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Repeat” to toggle the operating mode be-
tween the “

Repeater

” mode and “

Base Transceiver

mode.

For normal operation, set this key to the “

Repeat

” mode.

When the “

Base Transceiver

” mode is selected, you can

speak into the microphone to use this repeater as a trans-
ceiver.

R

ESET

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Reset” to reset (same function as the

POWER

 switch “off” and “on”) the repeater.

P

ROGRAMMABLE

 F

UNCTION

 

(

PF

)

 K

EY

 D

ETAILS

4

Summary of Contents for VXR-9000

Page 1: ...TANDARD US Headquarters 10900 Walker Street Cypress CA 90630 U S A YAESU EUROPE B V P O Box 75525 1118 ZN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Close Wincheste...

Page 2: ...VXR 9000 FM REPEATER OPERATING MANUAL...

Page 3: ...result from im proper setup programming or internal modifications SAFETY WARNINGINFORMATION The antenna s used for this transmitter must be fixed mounted on outdoor permanent structures with a separat...

Page 4: ...STANDARD dealer to meet your communications network requirements Note that some functions may require the purchase of optional internal ac cessories The possible PF key features and func tions are ex...

Page 5: ...to CTCSS DCS Enc to turn the CTCSS DCS Encoder On or Off toggle CTCSS DCSDEC Press or Press and hold in for one second the PF key assigned to CTCSS DCS Dec to turn the CTCSS DCS Decoder On or Off togg...

Page 6: ...or Press and hold in for one second the PF key assigned to Local PTT to enable On or disable Off operation using a PTT switch connected to the front panel s Microphone Jack MONITOR Press or Press and...

Page 7: ...tch to transmit the Test Tone Signal as programmed by your VERTEX STANDARD dealer TOT Press or press and hold in one second the PF key as signed to TOT to turn the Time Out Timer feature On or Off tog...

Page 8: ...ing antenna or the TX jack on the duplexer The out put impedance requirement is 50 Ohms Main Power Source Connector The primary DC power source should be connected here The power requirements are 13 6...

Page 9: ...nnecting the shield to GND Pin 5 TX ATT This output is intended for controlling an external co axial switching relay It is an open drain output which can sink approx 1 5 A when active The delay time w...

Page 10: ...supply return Pin 22 RXD LOW ANALOG OUTPUT FOR DATA COMMUNICATIONS 300 3 000 Hz This pin is an output for low speed receiving data sig nals typically 1200 bps with the data being extracted after the d...

Page 11: ...at the operating frequency When separate receive and transmit antennas are used high Q narrow band types may serve to minimize interaction NEVER TRANSMIT WITHOUT HAVING A TRANSMIT ANTENNA CONNECTED TO...

Page 12: ...P termi nal posts on the rear panel While the repeater is oper ating from the Main Power Source a slight charging current will maintain battery charge In the event of an unexpected interruption of the...

Page 13: ...d Accessories DC Power Cord T9023499 1 15 A Blade Fuse Q0000075 1 Knob Cap RA0506900 1 Operating Manual 1 Optional Accessories FIF 9 Inline Interface Box FVP 25 Encryption Unit FVP 35 Rolling Code Enc...

Page 14: ...tivity 0 35 V 12dB SINAD 0 45 V 20dB Noise Quieting Selectivity 83 dB Wide 75 dB Narrow Intermodulation 82 dB Wide 78 dB Narrow Image Rejection 90 dB Squelch Threshold 5 dB Audio Output 4 W 4 ohm Audi...

Page 15: ...VXR 9000 FM REPEATER OPERATING MANUAL Part 15 21 Changes or modifications to this device not expressly ap proved by Vertex Standard could void the user s authorization to operate this device...

Page 16: ...ATER OPERATING MANUAL Copyright 2004 VERTEX STANDARD CO LTD All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO LTD Printed in Japan 0311J 0E E...

Reviews: