Yaesu VXR-9000 Operating Manual Download Page 3

VXR-9000 FM R

EPEATER

 O

PERATING

 M

ANUAL

The 

VXR-9000

 is commercial-grade 50-watt FM repeater designed to provide reliable two-way full-duplex commu-

nications over a wide range of environmental conditions.

Designed to mount in a standard 19-inch rack, the 

VXR-9000

 is crafted using the latest computer-aided design and

manufacturing processes, to ensure a high level of reliability to users. Important channel frequency data is stored in
EEPROM, and is easily programmable by a Servicing Technician or Dealer using an IBM compatible personal com-
puter and the 

VPL-1

 Programming Cable and 

CE60

 Software.

Please take a few minutes to read this manual carefully. The information presented here will allow you to derive
maximum performance from your 

VXR-9000

. After reading it, keep this manual handy for quick reference, in case

questions arise later on.

Important Note: Internal service work, programming, and accessory installations should only be performed by your
authorized Vertex Standard Dealer. Dangerous conditions and/or possibly illegal operation may result from im-
proper setup, programming, or internal modifications.

S

AFETY

/W

ARNING

 

INFORMATION

The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a
separation distance of at least 74cm from all persons during normal operation and must not exceed an
antenna gain of 0 dBd. This device must be restricted to work related operations in an Occupational/Con-
trolled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%.  The antenna(s)
used with this device must satisfy the antenna co-location requirements of 47 C.F.R. 1.1307(b)(3).

N

OTICE

!

Do not modify this repeater for any reason.
Refer service of this repeater to qualified technicians only.

When the repeater become abnormal, such as the overheating, smoke smell of burning, etc., turn the main
power switch off and disconnect the Main Power Source connector from the rear of the 

VXR-9000

 imme-

diately. Also disconnect any backup power source you may have connected to the rear of the 

VXR-9000

.

Do not place any combustible material near the repeater.

Do not spray any liquid over the repeater.

Ensure that the power and antenna connections are securely made, using cables with excess capacity for
the power being utilized.

I

NTRODUCTION

1

Summary of Contents for VXR-9000

Page 1: ...TANDARD US Headquarters 10900 Walker Street Cypress CA 90630 U S A YAESU EUROPE B V P O Box 75525 1118 ZN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Close Wincheste...

Page 2: ...VXR 9000 FM REPEATER OPERATING MANUAL...

Page 3: ...result from im proper setup programming or internal modifications SAFETY WARNINGINFORMATION The antenna s used for this transmitter must be fixed mounted on outdoor permanent structures with a separat...

Page 4: ...STANDARD dealer to meet your communications network requirements Note that some functions may require the purchase of optional internal ac cessories The possible PF key features and func tions are ex...

Page 5: ...to CTCSS DCS Enc to turn the CTCSS DCS Encoder On or Off toggle CTCSS DCSDEC Press or Press and hold in for one second the PF key assigned to CTCSS DCS Dec to turn the CTCSS DCS Decoder On or Off togg...

Page 6: ...or Press and hold in for one second the PF key assigned to Local PTT to enable On or disable Off operation using a PTT switch connected to the front panel s Microphone Jack MONITOR Press or Press and...

Page 7: ...tch to transmit the Test Tone Signal as programmed by your VERTEX STANDARD dealer TOT Press or press and hold in one second the PF key as signed to TOT to turn the Time Out Timer feature On or Off tog...

Page 8: ...ing antenna or the TX jack on the duplexer The out put impedance requirement is 50 Ohms Main Power Source Connector The primary DC power source should be connected here The power requirements are 13 6...

Page 9: ...nnecting the shield to GND Pin 5 TX ATT This output is intended for controlling an external co axial switching relay It is an open drain output which can sink approx 1 5 A when active The delay time w...

Page 10: ...supply return Pin 22 RXD LOW ANALOG OUTPUT FOR DATA COMMUNICATIONS 300 3 000 Hz This pin is an output for low speed receiving data sig nals typically 1200 bps with the data being extracted after the d...

Page 11: ...at the operating frequency When separate receive and transmit antennas are used high Q narrow band types may serve to minimize interaction NEVER TRANSMIT WITHOUT HAVING A TRANSMIT ANTENNA CONNECTED TO...

Page 12: ...P termi nal posts on the rear panel While the repeater is oper ating from the Main Power Source a slight charging current will maintain battery charge In the event of an unexpected interruption of the...

Page 13: ...d Accessories DC Power Cord T9023499 1 15 A Blade Fuse Q0000075 1 Knob Cap RA0506900 1 Operating Manual 1 Optional Accessories FIF 9 Inline Interface Box FVP 25 Encryption Unit FVP 35 Rolling Code Enc...

Page 14: ...tivity 0 35 V 12dB SINAD 0 45 V 20dB Noise Quieting Selectivity 83 dB Wide 75 dB Narrow Intermodulation 82 dB Wide 78 dB Narrow Image Rejection 90 dB Squelch Threshold 5 dB Audio Output 4 W 4 ohm Audi...

Page 15: ...VXR 9000 FM REPEATER OPERATING MANUAL Part 15 21 Changes or modifications to this device not expressly ap proved by Vertex Standard could void the user s authorization to operate this device...

Page 16: ...ATER OPERATING MANUAL Copyright 2004 VERTEX STANDARD CO LTD All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO LTD Printed in Japan 0311J 0E E...

Reviews: