VX-8GE O
PERATING
M
ANUAL
141
S
ET
M
ODE
I
TEM
67: PRI TIME
Function
: Selects the time between the Priority (Dual Watch) channel checks, when the
feature is active.
Available Values
: 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step)
Default
: 5.0sec
S
ET
M
ODE
I
TEM
68: PTT DELAY
Function
: Selects the time delay before the carrier is transmitted, when the
PTT
switch is
pressed.
Available Values
: OFF / 20ms / 50ms / 100ms / 200ms
Default
: OFF
S
ET
M
ODE
I
TEM
69: RPT ARS
Function
: Enables/Disables the Automatic Repeater Shift function.
Available Values
: ON / OFF
Default
: ON
S
ET
M
ODE
I
TEM
70: RPT SHIFT
Function
: Sets the Repeater Shift Direction.
Available Values
: SIMPLEX / –RPT / +RPT
Default
: SIMPLEX
S
ET
M
ODE
I
TEM
71: RPT SHIFT FREQ
Function
: Sets the magnitude of the Repeater Shift.
Available Values
: 0.000MHz ~ 150.000MHz (50 kHz/step)
Default
: Depends on the operating band and transceiver version.
S
ET
M
ODE
I
TEM
72: RX MODE
Function
: Sets the receiving mode.
Available Values
: AUTO / NFM / AM
Default
: AUTO (Mode automatically changes according to operating frequency).
S
ET
M
ODE
I
TEM
73: SAVE RX
Function
: Selects the Receive-mode Battery Saver interval (“sleep” ratio).
Available Values
: 0.2sec ~ 0.9sec (0.1sec/step), 1.0sec ~ 9.5sec (0.5sec/step), or 10.0sec
~ 60.0sec (5sec/step)
Default
: 0.2sec
S
ET
M
ODE
I
TEM
74: SAVE TX
Function
: Enables/Disables the Transmitter Battery Saver.
Available Values
: ON / OFF
Default
: OFF
S
ET
M
ODE
S
ET
M
ODE
S
ELECTION
D
ETAILS