battery downward and out from the transceiver.

3.  To install, insert the battery pack into the battery compartment on the back of the

transceiver, then close the Battery Pack Latch until it locks in place with a “click.”

5.2 FBA-25 BATTERY CASE
FBA-25

 is a battery case that holds two alkaline batteries and is used with the 

HX370S

transceiver. Alkaline batteries can be used for transmission in an emergency, but power
output will only be 0.9 W, and battery life will be shortened dramatically.
1.  Slide the batteries into the 

FBA-25

 with the Negative [–] side of the batteries touching the

spring connections inside the 

FBA-25

.

2. Insert the 

FBA-25

 into the battery compartment on the back of the transceiver, then close

the Battery Pack Latch until it locks in place with a “click.”

Note:

 The battery indicator on the transceiver is only applicable to the 

FNB-83/FNB-V57IS

rechargeable battery. Disregard this indication when using alkaline batteries.

5.5 BATTERY SAFETY

Battery packs for your transceiver contains Nickel-Metal Hydride (Ni-MH, FNB-83) or
Nickel-cadmium (Ni-Cd, FNB-V57IS) batteries. This type of battery stores a charge powerful
enough to be dangerous if misused or abused, especially when removed from the
transceiver. Please observe the following precautions:

DO NOT SHORT BATTERY PACK TERMINALS

Shorting the terminals that power to the transceiver can cause sparks, severe overheating,
burns, and battery cell damage. If the short is of sufficient duration, it is possible to melt
battery components. Do not place a loose battery pack on or near metal surfaces or objects
such as paper clips, keys, tools, etc. When the battery pack is installed on the transceiver,
the terminals that transfer current to the transceiver are not exposed. The terminals that are
exposed on the battery pack when it is mounted on the transceiver are charging terminals
only and do not constitute a hazard.

DO NOT INCINERATE

Do not dispose of any Ni-MH or Ni-Cd battery in a fire or incinerator. The heat of fire may
cause battery cells to explode and/or release dangerous gases.

DISPOSE OF BATTERY PACKS PROPERLY

Ni-MH or Ni-Cd batteries must be recycled or disposed of properly. For requirements in your
area, check with the dealer from whom you purchased your transceiver. The symbol shown
below is a reminder that the battery packs are recyclable.

Summary of Contents for HX370S

Page 1: ...restricted to occupational use work related operations only where the radio operator must have the knowledge to control its RF exposure conditions When transmitting hold the radio in a vertical posit...

Page 2: ...ENSE INFORMATION This radio operates on communications frequencies which are subject to FCC Federal Communications Commission Rules and Regulations FCC Rules require that all operators using Marine Pr...

Page 3: ...nd 5 watts High Emission 16K0G3E Marine Band 16K0F3E 11K0F3E LMR Band Frequency Range 156 025 157 425 MHz Marine Band 137 174 MHz LMR Band FCC Type Number Industry Canada Type Approval Additional FCC...

Page 4: ...down the channels decrease continuously 6 16 9 KEY Immediately recalls channel 16 from any channel location Holding down this key recalls channel 9 7 SCAN KEY Starts scanning programmed channels Pres...

Page 5: ...ional mode H M L Indicator H is high power M is middle power and L is low power Blank is a reception only channel PRI Indicator Priority Scan is activated SCN Indicator Scan is activated TX Indicator...

Page 6: ...this point weak signals may not be received No noise or no signal is heard until a signal is received that exceeds the squelch threshold 5 To change channel press the UP or DOWN key Sometimes a slight...

Page 7: ...e LCD 3 Repeat steps 1 and 2 for all the channels to be scanned 4 To delete a channel from the transceiver s scan memory press the MEM key again while the memorized channel is displayed MEM disappears...

Page 8: ...9 Channel 9 is used as a hailing channel for initial non emergency contact with other vessels Hold down the 16 9 key for 1 second to select channel 9 4 12 OPERATING ON CHANNEL 13 Channel 13 is used at...

Page 9: ...MODE The HX370S s Set Mode system allows a number of transceiver operating parameters to be custom configured for your operating requirements The Set Mode is easy to activated and set using the follo...

Page 10: ...the Source transceiver cS will appear on the Source radio and the data is transferred 6 If there is a problem during the cloning process cE will displayed Check your cable connections and battery vol...

Page 11: ...dride Ni MH FNB 83 or Nickel cadmium Ni Cd FNB V57IS batteries This type of battery stores a charge powerful enough to be dangerous if misused or abused especially when removed from the transceiver Pl...

Page 12: ...r s memory The SCAN key does not start the scan Squelch is not adjusted Adjust the squelch to threshold or to the point where noise just disappears Further adjustment of the squelch control may elimin...

Page 13: ...range 20 to 60 C Marine 30 to 60 C LMR Case size W x H x D 58 x 120 x 30 5 mm Weight Approx 340 g Receiver Circuit type Double conversion superheterodyne Ifs 1st 21 7 MHz 2nd 450 kHz 12dB SINAD Sensit...

Page 14: ...device complies with Part 15 of the FCC Rules Operation is subject to the condition that this device does not cause harmful interference Part 15 21 Changes or modifications to this device not express...

Reviews: