Page 121
FT
DX
5000 O
PERATING
M
ANUAL
AGC G
ROUP
001 AGC FST DLY
Function
: Sets the delay time for the AGC FAST mode.
Available Values
: 20 msec ~ 4000 msec (20 msec/step)
Default Setting
: 300 msec
002 AGC FST HLD
Function
: Sets the hang time of the AGC peak voltage for
the AGC FAST mode.
Available Values
: 0 msec ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
003 AGC MID DLY
Function
: Sets the delay time for the AGC MID mode.
Available Values
: 20 msec ~ 4000 msec (20 msec/step)
Default Setting
: 700 msec
004 AGC MID HLD
Function
: Sets the hang time of the AGC peak voltage for
the AGC MID mode.
Available Values
: 0 msec ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
005 AG SLW DLY
Function: Sets the delay time for the AGC SLOW mode.
Available Values: 20 msec ~ 4000 msec (20 msec/step)
Default Setting: 3000 msec
006 AGC SLW HLD
Function
: Sets the hang time of the AGC peak voltage for
the AGC SLOW mode.
Available Values
: 0 msec ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
DISPLAY G
ROUP
007 DISP COLOR
Function
: Selects the Display color when the optional Data
Management Unit (
DMU-2000
) is connected.
Available Values
: BLUE1 / BLUE2 / WHITE /
UMBER1 / UMBER2
Default Setting
: BLUE1
A
DVICE
:
If the optional
DMU-2000
Data Management Unit is not
connected, this adjustment has no effect.
008 DISP DIM MTR
Function
: Setting of the meter brightness level when
“DIM” is selected.
Available Values
: 0 ~ 15
Default Setting
: 8
A
DVICE
:
You may see the effects of your changes by pressing the
[
DIM
] switch to activate the Dimmer function.
009 DISP DIM VFD
Function
: Setting of the frequency display brightness level
when “DIM” is selected.
Available Values
: 0 ~ 15
Default Setting
: 8
A
DVICE
:
You may see the effects of your changes by pressing the
[
DIM
] switch to activate the Dimmer function.
010 DISP DIM OEL
Function
: Setting of three Sub Displays brightness level
when “DIM” is selected.
Available Values
: 0 ~ 15
Default Setting
: 8
A
DVICE
:
You may see the effects of your changes by pressing the
[
DIM
] switch to activate the Dimmer function.
011 DISP DIM ELCD
Function
: Setting of the Spectrum Scope display bright-
ness level of the optional
SM-5000
Station Monitor when
“DIM” is selected.
Available Values
: 0 ~ 15
Default Setting
: 8
A
DVICE
:
You may see the effects of your changes by pressing
the [
DIM
] switch to activate the Dimmer function.
If the optional
SM-5000
Station Monitor is not con-
nected, this adjustment has no effect.
012 DISP BAR SEL
Function
: Selects one of three parameters to be viewed
on the Tuning Offset Indicator.
Available Values
: CLAR / CW TUNE
Default Setting
: CW TUNE
CLAR:
Displays relative clarifier offset.
CW TUNE: Displays relative CW tuning offset be-
tween the incoming signal and transmit-
ted frequency.
M
ENU
M