Page 124
FT
DX
5000 O
PERATING
M
ANUAL
GENERAL G
ROUP
038 GENE TRACK
Function
: Sets the VFO Tracking feature.
Available Values
: OFF / BAND / FREQ
Default Setting
: OFF
OFF:
Disables the VFO Tracking feature.
BAND: When you change bands on the VFO-A side,
the VFO-B will automatically change to be
the same as that of VFO-A.
FREQ: This function is the similar to “BAND”, addi-
tionally, the VFO-B frequency changes to-
gether with the VFO-A frequency when turn-
ing the Main Dial Tuning knob.
039 GENE TX TOT
Function
: Sets the Time-Out Timer countdown time.
Available Values
: OFF / 1min ~ 30min
Default Setting
: OFF
The Time-Out Timer shuts off the transmitter after con-
tinuous transmission of the programmed time.
040 GENE TRV 14M
Function
: Sets the 10’s and 1’s of the MHz digits display
for operation with a transverter when the exciter band is
14 MHz.
Available Values
: 30 MHz ~ 46 MHz
Default Setting
: 44 MHz
The default setting would be used with a 144 MHz
transverter. If you connect a 430 MHz transverter to the
radio, set this menu to “30” (the “100 MHz” digits are
hidden on this radio).
041 GENE TRV 28M
Function
: Sets the 10’s and 1’s of the MHz digits display
for operation with a transverter when the exciter band is
28 MHz.
Available Values
: 30 MHz ~ 46 MHz
Default Setting
: 44 MHz
The default setting would be used with a 144 MHz
transverter. If you connect a 430 MHz transverter to the
radio, set this menu to “30” (the “100 MHz” digits are
hidden on this radio).
042 GENE TRV 50M
Function
: Sets the 10’s and 1’s of the MHz digits display
for operation with a transverter when the exciter band is
50 MHz.
Available Values
: 30 MHz ~ 46 MHz
Default Setting
: 44 MHz
The default setting would be used with a 144 MHz
transverter. If you connect a 430 MHz transverter to the
radio, set this menu to “30” (the “100 MHz” digits are
hidden on this radio).
M
ENU
M
ODE
030 GENE ANT SEL
Function
: Sets the method of antenna selection.
Available Values: BAND / STACK
Default Setting
: BAND
BAND: The antenna is selected in accordance with
the operating band.
STACK: The antenna is selected in accordance with
the band stack (different antennas may be uti-
lized on the same band, if so selected in the
band stack).
031 GENE BEEP LVL
Function
: Sets the beep level.
Available Values
: 0 ~ 100
Default Setting
: 40
032 GENE CAT BPS
Function
: Sets the transceiver’s computer-interface cir-
cuitry for the CAT baud rate to be used.
Available Values
: 4800bps / 9600bps / 19200bps /
38400bps
Default Setting
: 4800bps
033 GENE CAT TOT
Function
: Sets the Time-Out Timer countdown time for a
CAT command input.
Available Values
: 10ms / 100ms / 1000ms / 3000ms
Default Setting
: 10ms
The Time-Out Timer shuts off the CAT data input after the
continuous transmission of the programmed time.
034 GENE CAT RTS
Function
: Enables/Disables the RTS port of the CAT jack.
Available Values
: DISABLE / ENABLE
Default Setting
: ENABEL
035 GENE CAT IND
Function
: Enables/Disables the flashing of the CAT LED
in conjunction with the CAT commands.
Available Values
: DISABLE / ENABLE
Default Setting
: ENABEL
036 GENE MEM GRP
Function
: Enables/Disables Memory Group Operation.
Available Values
: DISABLE / ENABLE
Default Setting
: DISABEL
037 GENE Q SPLIT
Function
: Selects the tuning offset for the Quick Split fea-
ture.
Available Values
: –20 kHz ~ 0 kHz ~ 20 kHz (1 kHz Step)
Default Setting
: 5 kHz