084 TUN DIALSTP

Function

: Setting of the Main Tuning Dial knob’s and the

[

CLAR/VFO-B

] knob’s tuning speed on the SSB, CW,

and AM modes.

Available Values

: 1/5/10 Hz

Default Setting

: 10 Hz

085 TUN CW FINE

Function

: Enabling/disabling of the “Fine” tuning speed

in the CW mode.

Available Values

: EnA/diS (ENABLE/DISABLE)

Default Setting

: diS (DISABLE)

EnA (ENABLE): Tuning in 1 Hz steps on the CW mode.
diS (DISABLE): Tuning according to the steps deter-

mined via menu item “

084 TUN

084 TUN

084 TUN

084 TUN

084 TUN

DIALSTP

DIALSTP

DIALSTP

DIALSTP

DIALSTP

”.

086 TUN MHz SEL

Function

: Selects the tuning steps for the [

CLAR/VFO-

B

] knob when the [

MHz

] button is pressed.

Available Values

: 1/0.1 MHz

Default Setting

: 1 MHz

087 TUN AM STEP

Function

: Selects the tuning steps for the microphone’s

[

UP

]/[

DWN

] keys in the AM mode.

Available Values

: 2.5/5/9/10/12.5 kHz

Default Setting

: 5 kHz

088 TUN FM STEP

Function

: Selects the tuning steps for the microphone’s

[

UP

]/[

DWN

] keys in the FM mode.

Available Values

: 5/6.25/10/12.5/20/25 kHz

Default Setting

: 5 kHz

089 TUN FM DIAL

Function

: Setting of the Main Tuning Dial knob’s and the

[

CLAR/VFO-B

] knob’s tuning speed in the FM mode.

Available Values

: 10/100 Hz

Default Setting

: 100 Hz

090 TUN MY BAND

Function

: Programs a band to be skipped while selecting

bands using the [

CLAR/VFO-B

] knob.

To program the band to be skipped, rotate the [

CLAR/

VFO-B

] knob to recall the band to be skipped while se-

lecting bands via the [

CLAR/VFO-B

] knob, then press

the [

ENT

] button to change this setting to “ON” (a “

d

dd

dd

notation will replace the “

E

EE

EE

” notation). Repeat the same

procedure to cancel the setting (skipped “Off”: “

d

dd

dd

” nota-

tion appears).

TX AUDIO G

ROUP

091 TAUD EQ1 FRQ

Function

: Selects the center frequency of the lower range

for the parametric microphone equalizer.

Available Values

: OFF/100 ~ 700 Hz (100 Hz/step)

Default Setting

: OFF

OFF:

The equalizer gain and Q-factor are set to fac-
tory defaults (flat).

100 ~ 700: Center frequencies of 100 Hz ~ 700 Hz.
You may adjust the equalizer gain and Q-factor at this se-
lected audio frequency via menu items “

092 TAUD EQ1

092 TAUD EQ1

092 TAUD EQ1

092 TAUD EQ1

092 TAUD EQ1

LVL

LVL

LVL

LVL

LVL

” and “

093 TAUD EQ1 BW

093 TAUD EQ1 BW

093 TAUD EQ1 BW

093 TAUD EQ1 BW

093 TAUD EQ1 BW

”.

092 TAUD EQ1 LVL

Function

: Adjusts the equalizer gain of the low range of

the parametric microphone equalizer.

Available Values

: –20 ~ +10

Default Setting

: +5

093 TAUD EQ1 BW

Function

: Adjusts the Q-factor of the low range of the

parametric microphone equalizer.

Available Values

: 1 ~ 10

Default Setting: 10

094 TAUD EQ2 FRQ

Function

: Selects the center frequency of the middle range

for the parametric microphone equalizer.

Available Values

: OFF/700 ~ 1500 Hz (100 Hz/step)

Default Setting

: OFF

OFF:

The equalizer gain and Q-factor are set to fac-
tory defaults (flat).

700 ~ 1500: Center frequencies of 700 Hz ~ 1500 Hz.
You may adjust the equalizer gain and Q-factor at this se-
lected audio frequency via menu items “

095 TAUD EQ2

095 TAUD EQ2

095 TAUD EQ2

095 TAUD EQ2

095 TAUD EQ2

LVL

LVL

LVL

LVL

LVL

” and “

096 TAUD EQ2 BW

096 TAUD EQ2 BW

096 TAUD EQ2 BW

096 TAUD EQ2 BW

096 TAUD EQ2 BW

”.

095 TAUD EQ2 LVL

Function

: Adjusts the equalizer gain of the middle range

of the parametric microphone equalizer.

Available Values

: –20 ~ +10

Default Setting

: +5

096 TAUD EQ2 BW

Function

: Adjusts the Q-factor of the middle range of the

parametric microphone equalizer.

Available Values

: 1 ~ 10

Default Setting

: 10

M

ENU

 M

ODE

Summary of Contents for FT-950

Page 1: ...lected Menu item 2 Rotate the SELECT knob to select the Menu item you wish to modify 3 Rotate the CLAR VFO B knob to change the cur rent setting of the selected Menu item ADVICE Press the CLEAR button...

Page 2: ...T SEL bAnd rEG bAnd GENERAL 025 GENE BEP LVL 0 100 50 GENERAL 026 GENE CAT BPS 4800 9600 192H 19200 384H 38400 bps 4800 bps GENERAL 027 GENE CAT TOT 10 100 1000 3000 msec 10 msec GENERAL 028 GENE CAT...

Page 3: ...RGEN CNTR LV 40 20 dB 15 dB RX GENERAL 070 RGEN CNTR WI 1 11 10 RX GENERAL 071 RGEN DNF OFF On OFF RX GENERAL 072 RGEN DNR OFF 1 15 OFF SCOPE 073 SCP 1 8 FIX 1 800 1 999 MHz 1 kHz steps 1 800 MHz 1 SC...

Page 4: ...O 102 TAUD PE1 BW 1 10 2 TX AUDIO 103 TAUD PE2 FRQ OFF 700 1500 Hz 100 Hz step 800 Hz TX AUDIO 104 TAUD PE2 LVL 20 10 0 TX AUDIO 105 TAUD PE2 BW 1 10 1 TX AUDIO 106 TAUD PE3 FRQ OFF 1500 3200 Hz 100 H...

Page 5: ...t has no effect 005 DISP DIM VFD Function Setting of the display brightness level Available Values 0 15 Default Setting 8 006 DISP BAR SEL Function Selects one of three parameters to be viewed on the...

Page 6: ...50 ADVICE If the optional DVS 6 Voice Memory Unit is not connected this adjustment has no effect 015 DVS TX LVL Function Sets the microphone input level to the optional DVS 6 Voice Memory Unit Availab...

Page 7: ...may enter the CW message from the CW keyer GENERAL GROUP 024 GENE ANT SEL Function Sets the method of antenna selection Available Values bAnd rEG Default Setting bAnd bAnd The antenna is selected in a...

Page 8: ...gain for the AM mode Available Values Ur 0 100 Default Setting Ur When this menu is set to Ur you may adjust the micro phone gain using the front panel s MIC GAIN knob MODE CW GROUP 037 A1A F TYPE Fu...

Page 9: ...044 A1A DELAY FuLL The transceiver will operate in the full break in QSK mode 044 A1A DELAY Function Adjusts the Keying Delay receiver recovery time on the CW mode Available Values 30 3000 msec 10 ms...

Page 10: ...ack Available Values 0 100 Default Setting 50 062 RTTY SHIFT Function Selects the frequency shift for RTTY AFSK operation Available Values 170 200 425 850 Hz Default Setting 170 Hz 063 RTTY TONE Funct...

Page 11: ...Hz 066 J3E USB CAR Function Adjusts the receiver carrier point for the USB mode Available Values 200 Hz 200 Hz 10 Hz steps Default Setting 0 Hz RX GENERAL GROUP 067 RGEN NB 1 LVL Function Adjusts the...

Page 12: ...FIX mode Spectrum Scope while monitoring on the 20 m amateur band Available Values 1 4 000 1 4 349 MHz 1 kHz steps Default Setting 1 4 000 MHz MENU MODE SCOPE GROUP ADVICE This group s adjustment has...

Page 13: ...o cancel the setting skipped Off d d d d d nota tion appears TX AUDIO GROUP 091 TAUD EQ1 FRQ Function Selects the center frequency of the lower range for the parametric microphone equalizer Available...

Page 14: ...vailable Values 1 10 Default Setting 2 MENU MODE 103 TAUD PE2 FRQ Function Selects the center frequency of the middle range for the parametric microphone equalizer when the speech processor is activat...

Page 15: ...f this frequency is restricted to sta tions operating in or near Alaska and only for emergency purposes never for routine operations See 97 401 c of the FCC s regulations for details TX GENERAL GROUP...

Reviews: