034 GEnE TRACK

Function

: Sets the VFO Tracking feature.

Available Values

: OFF / bAND / FrEq

Default Setting

: OFF

OFF:

Disables the VFO Tracking feature.

bAND: When you change bands on the Main (VFO-

A) side, the Sub (VFO-B) band’s VFO will
automatically change to be the same as that of
VFO-A.

FrEq:

This function is the almost same as “bAND,”
however, furthermore, the Sub band’s (VFO-
B) frequency changes together with the Main
Band’s (VFO-A) frequency when turning the
Main Dial Tuning knob.

035 GEnE TX TOT

Function

: Sets the Time-Out Timer countdown time.

Available Values

: OFF / 3 / 5 / 10 / 15 / 20 / 30 min

Default Setting

: OFF

The Time-Out Timer shuts off the transmitter after con-
tinuous transmission of the programmed time.

036 GEnE TRV SET

Function

: Sets the 10’s and 1’s of the MHz digits display

for operation with a transverter.

Available Values

: 30 ~ 49 MHz

Default Setting

: 44 MHz

The default setting would be used with a 144 MHz
transverter. If you connect a 430 MHz transverter to the
radio, set this menu to “30” (the “100 MHz” digits are
hidden on this radio).

037 GEnE 

μ

T DIAL

Function

: Selects the 

μ

-TUNE mode.

Available Values

: StP1 / StP2 / OFF

Default Setting

: StP1

StP1: Activates the 

μ

-TUNE system using

“COARSE” steps of the [

VRF

] knob (2 steps/

click) on the 7 MHz and lower amateur bands.
On the 10/14 MHz bands, “FINE” [

VRF

] knob

steps (1 step/click) will be used.

StP2: Activates the 

μ

-TUNE system using “FINE”

steps of the [

VRF

] knob (1 step/click) on the

14 MHz and lower amateur bands on the Main
band (VFO-A).

OFF: Disables the 

μ

-TUNE system. Activates the

VRF feature on the 14 MHz and lower amateur
bands on the main band (VFO-A).

A

DVICE

:

If the optional RF 

μ

Tuning Kit is not connected, this ad-

justment has no effect.

038 GEnE SNB LVL

Function

: Adjusts the Sub band (VFO-B) receiver’s IF

Noise Blanker level, when the Noise Blanker is engaged.

Available Values

: nAin(MAIN) / 0~100

Default Setting

: nAin(MAIN)

When this menu is set to “nAin(MAIN),” you may adjust
the Noise Blanker level using the front panel’s [

NB

] knob.

039 GEnE SUB FIL

Function

: Defines the Sub band (VFO-B) receiver’s CW

narrow filter.

Available Values

: 1200 / 500 / 300 Hz

Default Setting

: 1200 Hz

A

DVICE

:

This Menu item tells the microprocessor which (if any)
optional filter has been installed.

040 GEnE MIC SCN

Function

: Enables/disables scanning access via the

microphone’s [

UP

]/[

DWN

] keys.

Available Values

: On / OFF

Default Setting

: On

041 GEnE SCN RSM

Function

: Selects the Scan Resume mode.

Available Values

: CAr / 5SEc

Default Setting

: 5SEc

CAr: The scanner will hold until the signal disappears,

then will resume after one second.

5SEc: The scanner will hold for five seconds, then re-

sume whether or not the other station is still
transmitting.

042 GEnE ANTIVOX

Function

: Adjusts the Anti-VOX Trip Gain which is the

level of negative feedback of receiver audio to the micro-
phone, to prevent receiver audio from activating the trans-
mitter (via the microphone) during VOX operation.

Available Values

: 0 ~ 100

Default Setting

: 50

043 GEnE FRQ ADJ

Function

: Adjusts the reference oscillator.

Available Values

: –25 ~ 0 ~ +25

Default Setting

: 0

Connect a 50-Ohm dummy load and frequency counter to
the antenna jack; adjust the [

SUB VFO-B

] knob so that

the frequency counter reading is same as the VFO fre-
quency while pressing the 

PTT

 switch.

A

DVICE

:

Do not perform this Menu item unless you have a high-
performance frequency counter. Perform this Menu item
after aging the transceiver and frequency counter suffi-
ciently (at least 30 minutes).

M

ENU

 M

ODE

GENERAL G

ROUP

Summary of Contents for FT-2000 - MENU MODE LIST

Page 1: ...tly selected Menu item 2 Rotate the Main Tuning Dial knob to select the Menu item you wish to work on 3 Rotate the SUB VFO B knob to change the current setting of the selected Menu item ADVICE Press t...

Page 2: ...AL 026 GEnE ANT SEL bAnd rEG bAnd GENERAL 027 GEnE BEP LVL 0 100 50 GENERAL 028 GEnE CAT BPS 4800 9600 192H 19200 384H 38400 bps 4800 bps GENERAL 029 GEnE CAT TOT 10 100 1000 3000 msec 10 msec GENERAL...

Page 3: ...RTY 080 rtty RTY OUT nAin Main Sub nAin Main MODE RTY 081 rtty OUT LEL 0 100 50 MODE RTY 082 rtty SHIFT 170 200 425 850 Hz 170 Hz MODE RTY 083 rtty TONE 1275 2125 Hz 2125 Hz MODE SSB 084 J3E MIC SEL...

Page 4: ...100 Hz 100 Hz TUNING 124 tun MY BAND 1 8 50 GE AU TX AUDIO 125 tAUd EQ1 FRQ OFF 100 700 Hz 100 Hz step OFF TX AUDIO 126 tAUd EQ1 LVL 20 10 5 TX AUDIO 127 tAUd EQ1 BW 1 10 10 TX AUDIO 128 tAUd EQ2 FRQ...

Page 5: ...a Management Unit DMU 2000 is connected Available Values bL1 bL2 bL3 ub1 ub2 bL1 COOL BLUE bL2 CONTRAST BLUE bL3 FLASH WHITE ub1 CONTRAST UMBER ub2 UMBER Default Setting bL1 COOL BLUE ADVICE If the op...

Page 6: ...ACON Function Sets the interval time between repeats of the beacon message Available Values OFF 1 255 sec Default Setting OFF 019 tEy NUM STL Function Selects the Contest Number Cut format for an imbe...

Page 7: ...operating band rEG The antenna is selected in accordance with the band stack different antennas may be utilized on the same band if so selected in the band stack 027 GEnE BEP LVL Function Sets the bee...

Page 8: ...nal RF Tuning Kit is not connected this ad justment has no effect 038 GEnE SNB LVL Function Adjusts the Sub band VFO B receiver s IF Noise Blanker level when the Noise Blanker is engaged Available Val...

Page 9: ...he center frequency of the Sub band VFO B receiver s IF filter in the RTTY reverse mode Available Values 1000 1000 Hz 20Hz step Default Setting 0 Hz 050 S iF PKT LSB Function Sets the center frequency...

Page 10: ...r paddle s wiring configuration for the KEY jack on the rear panel Available Values nor rEU REV Default Setting nor nor Tip Dot Ring Dash Shaft Ground rEU REV Tip Dash Ring Dot Shaft Ground 058 A1A CW...

Page 11: ...e data input line connected to pin 1 of the PACKET jack while using the PKT mode PC This parameter is for future expansion of this transceiver s capabilities but at this time is not supported 067 dAtA...

Page 12: ...ne for RTTY operation Available Values 1275 2125 Hz Default Setting 2125 Hz MENU MODE MODE FM GROUP 074 F3E MICGAIN Function Sets the microphone gain for the FM mode Available Values Ur VR 0 100 Defau...

Page 13: ...z 087 J3E USB CAR Function Adjusts the receiver carrier point for Main band s VFO A USB mode Available Values 200 Hz 200 Hz 10 Hz step Default Setting 0 Hz 088 J3E SLSB CR Function Adjusts the receive...

Page 14: ...imary importance is attached to the amplitude of the filter factor 099 rdSP PKT SLP Function Selects the shape factor of the DSP filter for the PKT mode Available Values StP STEEP nEd MEDIUM GEnt GENT...

Page 15: ...scan start frequency of the FIX mode Spectrum Scope while monitoring on the 160 m amateur band Available Values 1 800 1 999 MHz 1 kHz step Default Setting 1 800 MHz 108 SCP 3 5 FIX Function Selects t...

Page 16: ...ing Dial knob s tuning speed except the FM and FM PKT modes Available Values 1 5 10 Hz Default Setting 10 Hz 119 tun CW FINE Function Enabling disabling of the Fine tuning speed in the CW RTTY and PKT...

Page 17: ...parametric microphone equalizer Available Values 1 10 Default Setting 10 131 tAUd EQ3 FRQ Function Selects the center frequency of the high range for the parametric microphone equalizer Available Valu...

Page 18: ...ualizer when the speech proces sor is activated Available Values 1 10 Default Setting 1 TX GNRL GROUP 143 tGEn BIAS This Menu item does not work Please do not change this setting 144 tGEn MAX PWR Func...

Reviews: