Page 109

FT-2000 O

PERATING

 M

ANUAL

M

ENU

 M

ODE

G

ROUP

N

O

.  M

ENU

 F

UNCTION

A

VAILABLE

 V

ALUES

D

EFAULT

 S

ETTING

AGC

001  AGc FST DLY

20 ~ 4000 msec (20 msec/step)

300 msec

AGC

002  AGc FST HLD

0 ~ 2000 msec (20 msec/step)

20 msec

AGC

003  AGc MID DLY

20 ~ 4000 msec (20 msec/step)

700 msec

AGC

004  AGc MID HLD

0 ~ 2000 msec (20 msec/step)

20 msec

AGC

005  AGc SLW DLY

20 ~ 4000 msec (20 msec/step)

2000 msec

AGC

006  AGc SLW HLD

0 ~ 2000 msec (20 msec/step)

20 msec

DISPLAY

007  diSP COLOR

bL1 / bL2 / bL3 / ub1 / ub2

bL1

Ú

1

DISPLAY

008  diSP DIM MTR

0 ~ 15

7

DISPLAY

009  diSP DIM VFD

0 ~ 7

4

DISPLAY

010  diSP BAR SEL

CLAr / C-tn / u-tn

C-tn

DISPLAY

011  diSP PK HLD

OFF / 0.5 / 1.0 / 2.0 sec

OFF

DISPLAY

012  diSP RTR STU

0 / 90 / 180 / 270°

DISPLAY

013  diSP RTR ADJ

–30° ~ 0° (2°/step)

DISPLAY

014  diSP QMB MKR

On / OFF

On

Ú

1

DISPLAY

015  diSP LVL IND

PI / SP / CO / nO / dn / Cd / Ud / rP / nG / Pr /

––

SH / UI

DVS

016  dUS RX LVL

0 ~ 100

50

DVS

017  dUS TX LVL

0 ~ 100

50

KEYER

018  tEy BEACON

OFF / 1 ~ 255 sec

OFF

KEYER

019  tEy NUM STL

1290 / AunO / Aunt / A2nO / A2nt / 12nO / 12nt 1290

KEYER

020  tEy CONTEST

1 ~ 9999

1

KEYER

021  tEy CW MEM1

tyP1 / tyP2

tyP2

KEYER

022  tEy CW MEM2

tyP1 / tyP2

tyP2

KEYER

023  tEy CW MEM3

tyP1 / tyP2

tyP2

KEYER

024  tEy CW MEM4

tyP1 / tyP2

tyP2

KEYER

025  tEy CW MEM5

tyP1 / tyP2

tyP2

Ú

2

GENERAL

026  GEnE ANT SEL

bAnd / rEG

bAnd

GENERAL

027  GEnE BEP LVL

0 ~ 100

50

GENERAL

028  GEnE CAT BPS

4800 / 9600 / 192H (19200) / 384H (38400) bps 4800 bps

GENERAL

029  GEnE CAT TOT

10 / 100 / 1000 / 3000 msec

10 msec

GENERAL

030  GEnE CAT RTS

On / OFF

On

GENERAL

031  GEnE CAT IND

On / OFF

On

GENERAL

032  GEnE MEM GRP

On / OFF

OFF

GENERAL

033  GEnE Q SPLIT

–20 ~ 0 ~ +20 kHz (1 kHz/step)

+5 kHz

GENERAL

034  GEnE TRACK

OFF / bAnd / FrEq

OFF

GENERAL

035  GEnE TX TOT

OFF / 3 / 5 / 10 / 15 / 20 / 30 min

OFF

GENERAL

036  GEnE TRV SET

30 ~ 49 MHz

44 MHz

GENERAL

037  GEnE 

μ

T DIAL

StP1 / StP2 / OFF

StP1

GENERAL

038  GEnE SNB LVL

nAin (MAIN) / 0~100

nAin(MAIN)

GENERAL

039  GEnE SUB FIL

1200 / 500 / 300 Hz

1200 Hz

GENERAL

040  GEnE MIC SCN

On / OFF

On

GENERAL

041  GEnE SCN RSM

CAr / 5Sec

5SEc

GENERAL

042  GEnE ANTIVOX

0 ~ 100

50

GENERAL

043  GEnE FRQ ADJ

–25 ~ 0 ~ +25

0

S IF SFT

044  S-iF LSB SFT

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

045  S-iF USB SFT

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

046  S-iF CWL SFT

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

047  S-iF CWU SFT

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

048  S-iF RTTY

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

049  S-iF RTTY-R

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

050  S-iF PKT-LSB

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

S IF SFT

051  S-iF PKT-USB

–1000 ~ +1000 Hz (20 Hz/step)

0 Hz

MODE-AM

052  A3E MICGAIN

Ur (VR) / 0 ~ 100

30

MODE-AM

053  A3E MIC SEL

Frnt / dAtA / PC

Frnt

Ú

1: Requires optional 

DMU-2000

 Data Management Unit.

Ú

2: Requires optional 

FH-2

 Remote Control Keypad.

Summary of Contents for FT-2000 - MENU MODE LIST

Page 1: ...tly selected Menu item 2 Rotate the Main Tuning Dial knob to select the Menu item you wish to work on 3 Rotate the SUB VFO B knob to change the current setting of the selected Menu item ADVICE Press t...

Page 2: ...AL 026 GEnE ANT SEL bAnd rEG bAnd GENERAL 027 GEnE BEP LVL 0 100 50 GENERAL 028 GEnE CAT BPS 4800 9600 192H 19200 384H 38400 bps 4800 bps GENERAL 029 GEnE CAT TOT 10 100 1000 3000 msec 10 msec GENERAL...

Page 3: ...RTY 080 rtty RTY OUT nAin Main Sub nAin Main MODE RTY 081 rtty OUT LEL 0 100 50 MODE RTY 082 rtty SHIFT 170 200 425 850 Hz 170 Hz MODE RTY 083 rtty TONE 1275 2125 Hz 2125 Hz MODE SSB 084 J3E MIC SEL...

Page 4: ...100 Hz 100 Hz TUNING 124 tun MY BAND 1 8 50 GE AU TX AUDIO 125 tAUd EQ1 FRQ OFF 100 700 Hz 100 Hz step OFF TX AUDIO 126 tAUd EQ1 LVL 20 10 5 TX AUDIO 127 tAUd EQ1 BW 1 10 10 TX AUDIO 128 tAUd EQ2 FRQ...

Page 5: ...a Management Unit DMU 2000 is connected Available Values bL1 bL2 bL3 ub1 ub2 bL1 COOL BLUE bL2 CONTRAST BLUE bL3 FLASH WHITE ub1 CONTRAST UMBER ub2 UMBER Default Setting bL1 COOL BLUE ADVICE If the op...

Page 6: ...ACON Function Sets the interval time between repeats of the beacon message Available Values OFF 1 255 sec Default Setting OFF 019 tEy NUM STL Function Selects the Contest Number Cut format for an imbe...

Page 7: ...operating band rEG The antenna is selected in accordance with the band stack different antennas may be utilized on the same band if so selected in the band stack 027 GEnE BEP LVL Function Sets the bee...

Page 8: ...nal RF Tuning Kit is not connected this ad justment has no effect 038 GEnE SNB LVL Function Adjusts the Sub band VFO B receiver s IF Noise Blanker level when the Noise Blanker is engaged Available Val...

Page 9: ...he center frequency of the Sub band VFO B receiver s IF filter in the RTTY reverse mode Available Values 1000 1000 Hz 20Hz step Default Setting 0 Hz 050 S iF PKT LSB Function Sets the center frequency...

Page 10: ...r paddle s wiring configuration for the KEY jack on the rear panel Available Values nor rEU REV Default Setting nor nor Tip Dot Ring Dash Shaft Ground rEU REV Tip Dash Ring Dot Shaft Ground 058 A1A CW...

Page 11: ...e data input line connected to pin 1 of the PACKET jack while using the PKT mode PC This parameter is for future expansion of this transceiver s capabilities but at this time is not supported 067 dAtA...

Page 12: ...ne for RTTY operation Available Values 1275 2125 Hz Default Setting 2125 Hz MENU MODE MODE FM GROUP 074 F3E MICGAIN Function Sets the microphone gain for the FM mode Available Values Ur VR 0 100 Defau...

Page 13: ...z 087 J3E USB CAR Function Adjusts the receiver carrier point for Main band s VFO A USB mode Available Values 200 Hz 200 Hz 10 Hz step Default Setting 0 Hz 088 J3E SLSB CR Function Adjusts the receive...

Page 14: ...imary importance is attached to the amplitude of the filter factor 099 rdSP PKT SLP Function Selects the shape factor of the DSP filter for the PKT mode Available Values StP STEEP nEd MEDIUM GEnt GENT...

Page 15: ...scan start frequency of the FIX mode Spectrum Scope while monitoring on the 160 m amateur band Available Values 1 800 1 999 MHz 1 kHz step Default Setting 1 800 MHz 108 SCP 3 5 FIX Function Selects t...

Page 16: ...ing Dial knob s tuning speed except the FM and FM PKT modes Available Values 1 5 10 Hz Default Setting 10 Hz 119 tun CW FINE Function Enabling disabling of the Fine tuning speed in the CW RTTY and PKT...

Page 17: ...parametric microphone equalizer Available Values 1 10 Default Setting 10 131 tAUd EQ3 FRQ Function Selects the center frequency of the high range for the parametric microphone equalizer Available Valu...

Page 18: ...ualizer when the speech proces sor is activated Available Values 1 10 Default Setting 1 TX GNRL GROUP 143 tGEn BIAS This Menu item does not work Please do not change this setting 144 tGEn MAX PWR Func...

Reviews: