background image

Warning:

 All operation should be strictly conform to the user manual. If not, result will be assumed by user.

 Must use original charger

 Pay attention to the type of battery and applied voltage. Mixture use is forbidden.

 Charging should be in ventilated environment. DO NOT charge in closed space or under high temperature. 

       DO NOT put charger into trunk or tail box while charging.

 While charging, connect battery with charger before connect with electric supply. After full charged, 

       cut off the electric supply before cut off the battery plug.

 When the green light turns on, please cut off the power in time. Avoid long time connection between charger 

       and AC power supply while not charging.

 While charging, if the signal light is abnormal, has different smell or the charger is over temperature, 

        please stop charging immediately and check or change the charger in time. 

 When using and storing the charger, please avoid foreign matter, especially water or other liquid in case of internal 

        short circuit. DO NOT bring charger within scooter, if have to, please make sure of damping.

 DO NOT disassemble or change the parts in charger by yourself.

Attention:

 If the battery can not be fully charged after 12 hours, please stop charging and contact your dealer.

 To maximize the battery life, please keep the battery percentage within 20% to 80%. 

 For storage, please keep the battery under 40°C to prevent irreversible capacity loss of the battery.

 Z3 battery will lose more capacity in lower temperature conditions. 

       To be more specific, the usable capacity at -10°C is 70%, 85% at 0°C and 100% at 25°C.

 The best battery capacity performance for storage is 50%. Storing battery with less than 10% or 

       more than 90% over a long period of time will cause irreversible capacity loss to the battery.

 The battery needs to take out from the scooter for  storage longer than one  week. In this condition, 

       please keep the battery at the temperature of 0°C to 20°C with capacity of 30%-70%. It's advised to 
       have at least one cycle of charge and discharge every 2 months to minimize battery capacity loss during storage. 
       If the battery failure is due to misuse or lack of proper maintenance as instructed, its warranty will be invalidated. 

 Falling may cause uncontrollable internal damage to the battery and may cause leakage, overheat, 

       smoking, fire or explosion.

20

21

Summary of Contents for Z3

Page 1: ...USER MANUAL V1 0 www globalyadea com...

Page 2: ...n the best driving state For effective protection of this scooter Please be sure to use original parts for YADEA products If you have any questions please contact our authorized service station or our...

Page 3: ...dealer for replacement or purchase of original parts Do not lend your scooter to those who can t operate a scooter for others safety and preventing unnecessary damage to your scooter Please keep this...

Page 4: ...Pay extra attention when riding through railway crossings junctions tunnels and bridges Slow down if road conditions are unclear Do not use high beam indiscriminately Continuous use of high beam may d...

Page 5: ...itch Speedometer Headlight Seat cushion Rear carrier Motor Tire Front shock absorber Front wheel Rear view mirror Front brake handle Throttle Power switch Rear brake handle Left grip Horn button Steer...

Page 6: ...eration Guide Power lock switch indication High beam Under voltage indicator Power indicator Speed Total mileage Turning signal indicator Safely start indicator Push and rotate anticlockwise To lock t...

Page 7: ...switch 10 11 Double ash switch P gear switch Turning light symbol Turn left to turn on the left turning light Turn right to turn on the right turning light Stop in the middle is turn off the turning l...

Page 8: ...the P gear switch again and the P gear will be locked Or if the motor stops rotating for more than 120 seconds after riding the p gear will be locked automatically After the P gear is locked the instr...

Page 9: ...he seat cushion lock at the left rear of the decoration boards Rotate to the right to open the seat cushion 2 Lift the rear of the seat cushion to open it and press it lightly to lock it 3 There is a...

Page 10: ...o proper protection Please do not use the electric energy to the minimum allowable voltage every time you ride When the undervoltage indicator ashes you must charge the battery It is best to form the...

Page 11: ...er output plug to the battery pack charging interface then connect the charger power plug to the household AC220V power supply and the indicator light is red This procedure is not allowed to reverse o...

Page 12: ...of damping DO NOT disassemble or change the parts in charger by yourself Attention If the battery can not be fully charged after 12 hours please stop charging and contact your dealer To maximize the...

Page 13: ...applying brakes If the tyres are locked and the scooter lose steering ability resulting from excessive braking force loosen the grip on the braking lever and the tyres will be working again and the s...

Page 14: ...and whether rotation is exible Whether the tire pressure is properly and whether the tire is worn Whether the lamp bulb is bright Whether the brake shoe is worn or not Whether the wheel rim is de ect...

Page 15: ...lease use original parts which are under normal warranty Warning If incapable of repair or adjustment on his her own the scooter owner is advised to send the scooter to the dealer s for maintenance an...

Page 16: ...if the side stand is on 1 Charge the battery 2 Check if it s properly connected 3 Replace Alarm Causes Troubleshooting Short time Storage 1 Keep the scooter in at steady well ventilated and dry area 2...

Page 17: ...ng or normal capacity loss 5 Low battery capacity resulting from low temperature Dead battery Identify the fault causes in reference to the meter panel fault codes Charge the battery 1 Charge the batt...

Page 18: ...ge Rated motor speed Rated voltage Rated ef ciency Loading weight 1810 750 1070 1310 78 0 5kg 15 25km h 45km h 50km 520 10 r min 60V 81 75kg 80N m 2 2kw h Lithium 60V26Ah AC110V50Hz AC220V50Hz 52 5V 4...

Page 19: ...34 35 Maintenance Record Malfuntion Description Malfuntion Description Service Station Serviced by Remarks Maintenance Record Malfuntion Description Malfuntion Description Service Station Serviced by...

Page 20: ...36 37 Malfuntion Description Remarks Maintenance Record Malfuntion Description Service Station Serviced by Remarks Maintenance Record Malfuntion Description Malfuntion Description Service Station Ser...