Yada AC532713 User Manual Download Page 9

9

12V AGM Battery Normal Mode

 is designed for AGM / GEL batteries 

orbatteries with capacities higher than 50Ah being charged under 

normal weather conditions. 

12V Lead-Acid Battery Cold Mode 

is designed for 12V Lead-Acid 

and AGM batteries with capacities higher than 50Ah being charged at 

cold temperatures (below 10°C).

24V Lead-Acid Battery Cold Mode 

is designed for 24V Lead-Acid 

and AGM batteries with capacities higher than 25Ah being charged at 

cold temperatures (below 10°C).

12V Maintain Mode 

is designed for 12V Lead-Acid, AGM, GEL and 

Lithium batteries being charged and maintained at 5A max.

12V Supply Mode 

works as a 12V DC power supply for powering 12V 

devices or as a memory retainer when replacing a battery.

12V Repair Mode 

is designed for 

12V LEAD-ACID BATTERIES ONLY

It is a battery recovery mode for repairing & restoring damaged, stratified 

and sulphated batteries. 

12V AGM Battery

(Normal Mode)

12V Lead-Acid Battery

(Cold Mode)

24V Lead-Acid Battery

(Cold Mode)

12V Maintain Mode

12V Supply Mode

12V Repair Mode

OPERATING INSTRUCTIONS CONT.:

CHARGING STATUS

While battery clamps are connected to the vehicle battery properly, STAND BY LED is 

ON, press the 

MODE

 button to start,  the LED Screen will show the charging status. 

Please see example below for 12V & 24V battery:  
Battery voltage, charging current and battery percentage charged will alternate every 

5 seconds.

Charging Current

Battery Voltage

Battery Percentage Charged

12V Lead-Acid Battery

5s.

5s.

VOLTAGE

AMPS

% CHARGED

iii) Fully Charged; Maintenance 

     Mode in Progress

i) 12V Battery Connected

ii) Charging in Process

j

n

n

m

h

g

l

l

+

+

Summary of Contents for AC532713

Page 1: ...User Manual 15A Battery Charger and Maintainer IMPORTANT READ THE ENTIRE INSTRUCTION MANUAL CAREFULLY AND MAKE SURE THAT YOU FULLY UNDERSTAND IT BEFORE YOU USE THE EQUIPMENT KEEP THE MANUAL FOR FUTUR...

Page 2: ...ery maintains all battery sizes IP68 Water resistant 8 x 4 5 x 2 4 inch 203 x 114 x 60 mm charger only 3 6 lb 1657 g Input Output Charging Voltage Charging Current Reverse Current Low Voltage Detectio...

Page 3: ...d If the mains lead is damaged it should only be replaced by a qualified electrician The charger should not be used if it is in any way damaged or malfunctioning Do not place the charger close to the...

Page 4: ...ctric shock or fire 8 To reduce risk of electric shock unplug charger from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk WARNING RISK OF EXPLOSIVE...

Page 5: ...all accessories in the vehicle are off so as not to cause an arc b Be sure area around battery is well ventilated while battery is being charged c Clean battery terminals Be careful to keep corrosion...

Page 6: ...tery Clamp from battery charger to POSITIVE POS P ungrounded post of battery Connect NEGATIVE BLACK Battery Clamp to vehicle chassis or engine block away from battery Do not connect Battery Clamp to c...

Page 7: ...ch long 6 gauge AWG insulated battery cable to NEGATIVE NEG N battery post c Connect POSITIVE RED charger Battery Clamp to POSITIVE POS P post of battery d Position yourself and free end of cable as f...

Page 8: ...Press MODE button to start charging Error indicator will be ON for reverse polarity poor connection low voltage battery over voltage battery and temperature protection 12V Lead Acid Battery Normal Mo...

Page 9: ...en replacing a battery 12V Repair Mode is designed for 12V LEAD ACID BATTERIES ONLY It is a battery recovery mode for repairing restoring damaged stratified and sulphated batteries 12V AGM Battery Nor...

Page 10: ...spot on the chassis that is some distance away from the battery itself and any fuel lines 4 Connect the AC power plug of battery charger into a wall socket Battery voltage is auto detected and chargin...

Page 11: ...l weather conditions iii 12V Lithium Battery Normal Mode is designed for 12V Lithium batteries including Lithium Iron Phosphate LiFePO4 batteries being charged under normal weather conditions PLEASE E...

Page 12: ...ions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or mor...

Reviews: