Solar charge controller Smart-MPPT Li series User Manual
Page 3 of 5 pages
Smart-MPPT Li series controller with advanced light
control function. The modes of lighting can be based on
customer needs.
7. Output Function
7.2
Dusk to Dawn
(
D2D
)
Dusk to Dawn(D2D)
Light on
Light off
D/N Thr
D/N Thr
Sunset
Sunrise
D/N Dly
If “Time1” of “DC 5-Stage” is set to “D2D”,the
controller works in dusk to dawn mode.
!
1.
Smart-MPPT
Li series controller is set to D2D mode,
the corresponding dimming setting is still valid.
2. If “Time1”is set to D2D mode, “Time4” can not be
set to T0T mode.
7.3 Five-stage Night Mode
Time1 Time2
Time5
Time3 Time4
Light on
Light off
D/N Thr
D/N Thr
Sunset
Sunrise
D/N Dly
You can set the Time 1-5 and Dim 1-5 with S-Unit.
7.4 T0T mode can set the load on time before
morning coming
(
)
D/N Thr
Time1
Time
2
Time5
Time3
T0T
Light on
Light off
D/N Thr
Sunset
Sunrise
D/N Dly
If "Time4" of the S-Unit is set to "T0T", this mode is T0T mode.
* If “Time4”is set to T0T mode, “Time1” can not set to D2D
mode.
8.LVD, LVR, Threshold
7.1 Standard(24H)
Light On
D/N Thr
D/N Thr
Sunset
Sunrise
If “Time1” of “DC 5-Stage” is set to “24H”and
sent to the controller successfully, the controller ’s
load will always be open.
8.3 Day/Night Threshold, Day/Night Delay
The controller recognizes day and night based on the solar array
open circuit voltage. This day/night threshold can be modified
according to local light conditions and the solar array used.
Day/Night threshold setting range: 3.0~20.0V.
8.1Low Voltage Disconnect(LVD)
!
1. Day/Night threshold voltage should be set around
0.22 times of open circuit voltage.
2.Day/Night threshold voltage of load disconnect is 1V
higher than the setting data, means the load will disconnect
when the solar voltage at 4.0~21.0V.
3.The controller has an automatic day/night threshold
adjustment function. If the lowest voltage of solar array is
higher than the setting day/night threshold, the load has no
output in first night, 24 hours later the controller can
automatically adjust the day/night threshold to meet the
requirements of lighting at night.
8.2Low Voltage Reconnect(LVR)
Low voltage reconnect setting range: 9.6~31.0V.
Low Voltage Disconnect
9.0~30.0V
setting range:
Sunset
Dusk
Sunrise
Dawn
3.0~20.0V
4.0~21.0V
!
1.If the controller goes into low voltage disconnect,
it
will restore only when the battery being recharged to the
recovery voltage.
2.
"LVR"should be higher than "LVD" at least 0.6V.
3.SMR-MPPT0875 Li Series:
Low Voltage Disconnect
setting range: 9.0~15.0V.
16
Low voltage reconnect setting range: 9.6~
.0V.
In the evening, when the solar array open circuit
voltage reaches the setting day/night threshold, you
can adjust the day/night delay time to make the load
turn on a little later.
Day/Night delay time setting range: 0~30min.