Page 2 of 5 pages

Solar charge controller Smart-MPPT Li series User Manual

5.Remote control, Default setting

!

Remark:

Be sure to set only one Smart-MPPT Li unit at 

a time.

Num

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

Factory Default

24H

100%

0H

100%

0H

100%

0H

100%

0H

100%

8.0V

0min

0.3A

No

LI

16.8V

16.4V

12.0V

12.6V

Name

Time1

Dim1

Time2

Dim2

Time3

Dim3

Time4

Dim4

Time5

Dim5

D/N Thr

D/N Dly

Load I

Dim Auto

Battery

CVT

CVR

LVD

LVR

5.1 Read the parameters

    Press the "Parameter" key of the S-Unit to read the 
setting parameters of the controller.

Num

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Name

Status

Batt V

Load I

Load V

PV

 

V

PV

 

I

Energy

OD Times

FC Times

Day1-HV

Day1-LV

Day2-HV

Day2-LV 

Day3-HV

Day3-LV

Name describe

Charge

Battery voltage

Load current

Load voltage

PV voltage

PV current      

Total generating capacity

Over discharge times

Fully charge times

A day ago highest voltage

A day ago lowest voltage

Two days ago highest voltage

Two days ago lowest voltage

Three days ago highest voltage

Three days ago lowest voltage

Unit

V

A

V

V

A

AH

Times

Times

V

V

V

V

V

V

5.2Read the running status

   Press the "Status" key of the S-Unit to read the 
running status of the controller.

When Smart-MPPT Li series controller is connected to the 
system, you can choose “DC 5-Stage”icon on the display 
of S-Unit infrared remote controller, as shown below!
Detailed setting operations, please read S-Unit User 
Manual.

6.Starting up the controller

6.1 el

t

 S f Tes

  

s o

 

e ontr

r

p ed i  ba er

   A  s on as th  c

olle  is su pli

 w th

tt y, it 

r

f t t

in

he  th  d s l  c a

 

sta ts a sel es  rout e. T

n

e i p ay h nges to

e a on.

normal op r ti

 

2

t

6.  Ba tery Type

 

h c

e is a

e  

i m  e

g a e

.

   T e  ontroll r    ppli d to Lith u

r char e bl  battery    

T

 

rg n

e

r

t a

gin

t

e

he cha i g voltag  ta ge   nd char

g vol age recov ry 

 

d n

c s

r

can be set accor i g to  u tome  requirements.

e on

i

 

  ~   e

s l h u

t

Th  c

troller is su table for 3 8 s rie   it i m ba tery.

l

g   f

l

i

a

 

.7

d

(The nomina  volta e o  a sing e l thium b ttery is 3 V an  

e h

i g volt

e     .2

th  c arg n  

age targ t is 4 V).

MPPT

45

°

!

  

1.Dimming function, if you set 0%, the load will be 

off, otherwise the load will be on.                                                         
2.The setting data of“Load I”and“Dim Auto”is for 
“DC”series with LED driver built-in, does not affect the 
operation of this type controller.

5.3 Test function(Streetlight mode)

  Press the“Test”key of S-Unit, the controller will 

turn on load for 1min.  During daytime, the testing 
function can help users to verify correct installation 
or for system trouble shooting. 1min later the load 
will automatically turn off. 

Note:  Default “24H”mode, the test key is invalid. 

  