Specifications

Item

Description

Type

12A Thermal Circuit Breaker with integrated ON/OFF switch.

Dimensions

Height -- 2.8 cm. (1.2 in.)
Depth -- 13.5 cm. (5.3 in.)
Width -- 35.6 cm. (13.98 in.)

Weight

0.44 kg. (1 lb.)

Display lights

CS (Control Store Run LED)

Controls

ON/OFF switch and Control Store Run/Reset push button switch

Operating Environment

20% to 80% humidity, noncondensing, 0° - 40° C (32° - 104° F)

Input Voltage

110 - 240 Vac  50 - 60 Hz

Power

Maximum:

120V - 10.0A
240V - 5.0A

+5V - 3.0A
+12V - 0.3A
-12V - 0.3A

Enclosure Requirements

One I/O slot in a Redundant Network 9000 intra-networking hub.

Emissions Compliance

FCC Class A, EEC/89/336 Class A

Order Codes

Product Name and Description

Order Code

Classic Network 9000 Redundant Fifteen-Slot Chassis

N9-9015-022

(includes two Redundant AC Power Control Modules)

Switchplane Network 9000 Redundant Fifteen-Slot Chassis

N9-9115-022

(includes two Redundant AC Power Control Modules)

Redundant AC Power Input Module (spare)

N9-000-119R

7

Summary of Contents for 119R

Page 1: ...Product Notes Network 9000 Model 119R Redundant AC Power Input Modules Xyplex Networks Incorporated 295 Foster Street Littleton MA U S A 01640 451 0054C...

Page 2: ...to revise this publication and to make changes in content from time to time without obligation to provide notification of such revision or changes Xyplex Networks Inc assumes no responsibility for er...

Page 3: ...s covered in this Guide include Product Prerequisites Controls and Indicators Installation Notes Operation Restrictions Specifications Order Codes Product Prerequisites Redundant AC Power Input Module...

Page 4: ...the bottom slot of the Network 9000 chassis the other in slot 10 Xyplex Networks recommends that you order 2 or 4 power supplies for the chassis to ensure power supply redundancy 2...

Page 5: ...supply modules and Redundant AC Power Input Modules using the standard Network 9000 installation and removal procedures that are described in Chapter 3 of the Network 9000 Installation Guide If you a...

Page 6: ...upplies that are associated with the functioning power input module take over the entire load To make sure that each segment of the split midplane receives power install power supplies in pairs into p...

Page 7: ...ules in power supply slots 1 2 and 3 while the Redundant AC Power Input Module in I O module slot 10 provides AC power to the power supply modules in power supply slots 4 and 5 Both Redundant AC Power...

Page 8: ...sor module to update its chassis parameters If you do not update the replacement module and the other power input module fails then all control storage parameters will be lost and there would a mismat...

Page 9: ...4 F Input Voltage 110 240 Vac 50 60 Hz Power Maximum 120V 10 0A 240V 5 0A 5V 3 0A 12V 0 3A 12V 0 3A Enclosure Requirements One I O slot in a Redundant Network 9000 intra networking hub Emissions Compl...

Reviews: