Xyplex 119R Product Notes Download Page 3

Introducing the Network 9000

Redundant AC Power Input Module

These notes cover the  Model 119R Redundant AC Power Control Module for  Redundant Network
9000 fifteen-slot chassis, including classic and switchplane chassis.  (Order codes are listed on the
last page.). The 119R AC Power Input Module provides the means to ensure uninterrupted service,
in the event of a power system failure, when an AC circuit within a facility fails, or when an AC
Power Input Module fails.  These modules are included with the redundant version of the Network
9000 fifteen-slot chassis, and are similar to the standard Network 9000 AC Power Input Module in
appearance, features, and operation.  Figure 1 depicts the 119R Redundant AC Power Input Module.

11/5230V~
12/6A

50-60Hz

ON

OFF

CS

119R

I/O Connector

REDUNDANT 08-00-87-xx-xx-xx

Figure 1.  Network 9000 Redundant AC Power Input Module.

Specific topics covered in this Guide include:

• Product Prerequisites

• Controls and Indicators

• Installation Notes

• Operation

• Restrictions

• Specifications

• Order Codes

Product Prerequisites

Redundant AC Power Input Modules require a Redundant Network 9000 fifteen-slot chassis which
includes a "split" midplane.  Not all Network 9000 fifteen slot chassis include a split midplane.
An installed standard Network 9000 fifteen-slot chassis can be upgraded to a Redundant chassis,
but this requires that you return the chassis to the factory.  Your Xyplex Networks sales
representative or distributor can give you more information about upgrading an installed chassis.

Redundant AC Power Input Modules are included as part of the redundant Network 9000 fifteen-
slot chassis configuration, or can be ordered separately as a replacement power input module for
an installed Redundant Network 9000 fifteen-slot chassis.

Each Redundant Network 9000 fifteen-slot chassis comes with two Redundant AC Power Input
Modules pre-installed in the chassis.  One Redundant AC Power Input Module is installed in slot 1

1

Summary of Contents for 119R

Page 1: ...Product Notes Network 9000 Model 119R Redundant AC Power Input Modules Xyplex Networks Incorporated 295 Foster Street Littleton MA U S A 01640 451 0054C...

Page 2: ...to revise this publication and to make changes in content from time to time without obligation to provide notification of such revision or changes Xyplex Networks Inc assumes no responsibility for er...

Page 3: ...s covered in this Guide include Product Prerequisites Controls and Indicators Installation Notes Operation Restrictions Specifications Order Codes Product Prerequisites Redundant AC Power Input Module...

Page 4: ...the bottom slot of the Network 9000 chassis the other in slot 10 Xyplex Networks recommends that you order 2 or 4 power supplies for the chassis to ensure power supply redundancy 2...

Page 5: ...supply modules and Redundant AC Power Input Modules using the standard Network 9000 installation and removal procedures that are described in Chapter 3 of the Network 9000 Installation Guide If you a...

Page 6: ...upplies that are associated with the functioning power input module take over the entire load To make sure that each segment of the split midplane receives power install power supplies in pairs into p...

Page 7: ...ules in power supply slots 1 2 and 3 while the Redundant AC Power Input Module in I O module slot 10 provides AC power to the power supply modules in power supply slots 4 and 5 Both Redundant AC Power...

Page 8: ...sor module to update its chassis parameters If you do not update the replacement module and the other power input module fails then all control storage parameters will be lost and there would a mismat...

Page 9: ...4 F Input Voltage 110 240 Vac 50 60 Hz Power Maximum 120V 10 0A 240V 5 0A 5V 3 0A 12V 0 3A 12V 0 3A Enclosure Requirements One I O slot in a Redundant Network 9000 intra networking hub Emissions Compl...

Reviews: