Installation
DIQ/S 281
30
ba77244d01
08/2020
figure 3-12 Prepared power cable.
The ground wire must not project into the enclosure. Otherwise, malfunctions
could occur.
Connecting the
power line
figure 3-13 Inserting the supply line.
approx. 45 mm
L
N
cut ground wire here
5
On the left-hand side of the DIQ/S 28X, remove the two countersunk
screws and open the enclosure.
6
Screw a cable gland (pos. 1 in figure 3-13) with sealing ring (pos. 2) into
the enclosure below the power supply connection.
7
Loosen the coupling ring (pos. 3).
8
Feed the power line through the cable gland into the enclosure. When
doing so bend the flexible divider (pos. 4) to the right.
1
3
2
4
L
N