The PolluCom
®
F/S C coaxial meter is used to
measure energy consumption in systems in which
water is used as heating or cooling fluid. The use
of water with anti-freeze additive is possible with
PolluCom
®
F/S C in this case the meter is not MID
compliant and a correction factor will need to be
programmed.
These installation and operating instructions
describe the installation and operation of all
variants. These instructions are an integral part of
the items supplied and must be given to the end
user.
Contents
1. General information ...
Fehler! Textmarke nicht
definiert.
2. Technical Data .................................................. 4
3. Important information ........................................ 4
4. Required tool .................................................... 5
5. Mounting the counter ........................................ 5
F/S C Installation instructions for all
types ............................................................................ 5
F/S C (Type Sensus) ....................... 5
F/S C RI (Typ Ista) ........................... 6
F/S C RT (Techem type) ................. 7
F/S C RA (Allmess type) ................. 8
6. Mounting the temperature sensor ..................... 8
6.1 Installation directly into the heating or Cooling
medium ........................................................................ 9
7. Display Options ................................................. 9
7.1 User level (L 1) ..................................................... 9
7.2 Reference date level (L 2) .................................10
7.3 Archive level (L 3) ..............................................10
7.4 Service level (L 4) ..............................................11
7.5 Rate function level (L 5) ....................................12
7.6 Parameter level (L 6) .........................................12
8. Function test, sealing ...................................... 13
9. Possible error situations ................................. 13
10. Optical interface and optional data transfer .. 14
10.1 Optical interface ...............................................14
10.2 M-Bus option in accordance with EN 13757-3
....................................................................................14
10.3 Optional remote reading for heat or cold
consumption impulses .............................................14
10.4 M-Bus option with two contact inputs ............14
10.5 Integrated data logger .....................................15
10.6 Wireless M-Bus, (wM-Bus) .............................15
11. Battery supply ............................................... 15
12. CE declaration of conformity ........................ 16
13. Identification and labeling of immersion
sleeves in existing systems ................................ 17
13.1 Legal background ............................................17
13.2 Identification of the thermowell in the field ....17
13.3 Identification of the immersion sleeves .........17
14. Tolerance list ................................................ 18
15. Other useful PolluCom® F/S C documents .. 19
Items delivered
•
PolluCom
®
F/S C
•
2 seals
•
Sealing material
•
Half-shell mounting set and a mounting aid
for the installation of the temperature sensor
•
Additionally for the versions with removable
calculator: 1 wall adapter, cable ties, 1
adhesive foil
•
These installation instructions
1. General information
Purpose of this document
These instructions contain the information
necessary for commissioning and using the device.
Read these instructions carefully before mounting
and commissioning. For correct use of the device,
first familiarize yourself with its method of
operation. The instructions are intended for
persons who physically install the device, connect
it electrically, configure and commission it, as well
as for service and maintenance personnel.
Qualified personnel
The product/system described in this
documentation should only be operated by
qualified personnel, and in accordance with the
relevant documentation Qualified personnel are
persons who, based on their training and
experience, are able to recognize risks and avoid
potential hazards whilst working with these
products and ensure appropriate assembly and
use of the product/system.
Trademarks
All names marked with ® (e.g. PolluCom
®
) are
registered trademarks of Sensus Spectrum LLC,
Raleigh. The other trademarks in this publication
may be trademarks whose use by third parties for
their own purposes could violate the rights of the
owner.