background image

7

The last 20 errors including error code (e.g.
ER01, page 11) are shown here as well as the
relevant operating hours until the message 
occurs. E01 is the most recent error, E20 is
the oldest.

Summary of Contents for Lowara Servitec

Page 1: ...mentioned above The following instructions must be read and understood by all persons responsible for the installation operation and maintenance of this product Warning Symbols Safety instructions wh...

Page 2: ...must be made using the appropriate wiring drawings for the equipment being installed with particular attention being paid to the supply voltages The supply voltage is shown on the set duty plate Neve...

Page 3: ...will work independently of the Lowara Servitec unit In this case the water make up port 3 can be blanked off and not used It is possible to connect a basic fill unit to the system for water make whic...

Page 4: ...4 Specific system set points The display shows the servitec type selected servitec magcontrol or servitec levelcontrol The system type can be specified here Select levelcontrol System fill pressure...

Page 5: ...5 Select continuous gassing time And confirm with OK button Select the degassing program Confirm with OK button Select the degassing program Confirm with OK button...

Page 6: ...6 Configure the setting here for whether a water meter is to be evaluated e g when using Lowara fillset with contact meter 0 Only alarm Factory settings 1 Alarm messages...

Page 7: ...7 The last 20 errors including error code e g ER01 page 11 are shown here as well as the relevant operating hours until the message occurs E01 is the most recent error E20 is the oldest...

Page 8: ...on temperature can be read off the displaY after a short time This is possible because the pump 6 draws more water from the pump casing than is able to flow in via the pressure supply port with nozzle...

Page 9: ...nterval degassing Economy mode in automatic mode After 8 intervals standard a break standard 23 h is observed before the next 8 degassing intervals are started This program is automatically started up...

Page 10: ...of the messages are automatically acknowledged once the cause has been remedied see table Errors such as Make up time 06 or Make up cycle 07 must be acknowledged manually For remote transmission it is...

Page 11: ...ory use Maintenance instructions Disassembly Maintenance work should only be carried out by specialists As a reminder of the annual maintenance the message SrV is shown in the display after a year of...

Page 12: ...97 630230 Fax 01297 630270 e mail lowaraukenquiries xyleminc com http www lowara co uk http completewatersystems com Lowara is a trademark of Xylem Inc or one of its subsidiaries 2011 Xylem Inc Lowara...