Installation, Operating and Maintenance Instruction
Model LR, LMR, LRZ, LMZ
Set the pump unit on the base and adjust the
nozzles. Anchor bolts must be cast with the
foundation.
If vibrations are transmitted to the foundation from
adjoining components, it must be guarded through
adequate vibration damping padding (vibrations
from outside can impair the bearing).
To prevent vibrations being transmitted to
adjoining components, the foundation should be
laid on a suitable insulating base.
The size of these insulating pads will vary,
depending on circumstances, and should
therefore be determined by an experienced
specialist.
5.2 Connection of Piping to the Pump
The pump must not be used as fixed point for
the piping. The permitted piping loads must not
be exceeded, refer to chapter 3.7.
5.2.1 Suction and discharge pipe
The pipes must be of a size and design that liquid
can flow freely into the pump and that the pump
functions without problems. Particular attention is
to be paid to ensuring that suction pipes are
airtight and that the NPSH values are observed.
Under suction lift condition the suction pipe lays in
the horizontal section towards the pump so that it
is slightly inclined upwards so that no air traps
occur. Do not install fittings or elbows right before
the suction nozzle.
Piping for direct installation of LR-, LMR-, LRZ- or
LMZ-pumps must show adequate firmness. Keep
in mind vibration insulation (see chapter 5.1).
When laying the pipes, make sure that the pump
is accessible for maintenance, installation and
disassembly.
Notice "Permitted Forces on Flanges" (chapter
3.7).
Before connecting up to pump: remove protective
coverings from suction and discharge branches.
Before starting up, the pipe system, fittings and
equipment must be cleaned to remove weld
spatter, scale etc. Any pollutants are to be
completely removed from pump units that are
directly or indirectly connected to drinking water
systems before being installed and taken into use.
To protect the shaft sealing (especially mechanical
seals) against foreign impurities, it is
recommended that a sieve, 800 micron, is
installed in the suction / intake pipe when the
motor is being started up.
If the pipe system is tested with the pump
installed, do not exceed the maximum permitted
casing pressure of the pump and/or shaft sealing
(see data sheet).
When emptying the pipe after the pressure test,
make sure that the pump is treated properly
(danger of rust and problems when starting up).
5.2.2 Additional connections LR, LRZ
The following additional connections are available:
Connection
Description
Dimension
E
Pump drain
R3/8"
L
Air release
R1/8"
M
Pressure gauge
R3/8"
5.2.3 Additional connections LMR, LMZ
The following additional connections are available:
Connection
Description
Dimension
E
Pump drain
R3/8"
L
Air release
R1/4"
M
Pressure gauge
R1/4"
5.3 Drive
The motor design of the pump is shown in the order
confirmation or on the motor name plate.
Note the Operating Instructions of the motor
manufacturer.
If in the process of repair a new motor is used, the
following has to be noticed:
The motor must comply with the requirements
stated in sheet 1130.1A608
(order from
manufacturer, on demand).
Clean motor end and motor flange of new motor
carefully (remove varnish).
5.4 Electric Connection
Electrical connection work may only be carried
out by an authorised professional. The rules
and regulations valid for electrical technology,
especially those concerned with safety
measures, must be observed. The regulations
of the national power supply companies
operating in that area must also be observed.
Before starting work, check that the information on the
motor name plate is the same as the local mains
network. The power supply cable of the coupled drive
motor must be connected up in accordance with the
wiring diagram produced by the motor manufacturer.
A protective motor switch must be provided.
The direction of rotation must only be checked
when the pump is full. Dry running will cause
damage to the pump.
page 46
Summary of Contents for LOWARA LMR 125-160
Page 22: ...Einbau Betriebs und Wartungsanleitung Baureihe LR LMR LRZ LMZ Seite 18 ...
Page 40: ...Instructions de montage de service et de maintenance Série LR LMR LRZ LMZ Page 36 ...
Page 57: ...Installation Operating and Maintenance Instruction Model LR LMR LRZ LMZ page 53 ...
Page 65: ......
Page 66: ......
Page 67: ......