– Original instructions
22
CAUTION:
Ingress protection. IP55 (Type 1) rating can only be guaranteed if the unit is properly closed.
Make sure that there is no liquid on the unit before opening the plastic cover.
Ensure all cable glands and unused holes for glands are properly sealed.
Ensure that the plastic cover is properly closed.
Device damage through contamination. Do not leave unit without the Terminal Box Cover.
4.2 Unit installation
Install the unit according to the systems liquid flow.
Usually arrows on the pump housing show flow and rotating direction.
The standard rotating direction for the unit is Clockwise (seen from fan cover). For more
information contact Service.
The unit must be installed according to Figure 13.
Always install a backflow-prevention device on the delivery side.
Always install downstream the pressure transmitter (if any) supplied.
Figure 13: Unit installation