![Xylem LOWARA e-SVE Installation, Operation And Maintenance Manual Download Page 20](http://html2.mh-extra.com/html/xylem/lowara-e-sve/lowara-e-sve_installation-operation-and-maintenance-manual_3844150020.webp)
en
– Original instructions
20
Free distance
Table 3: Free distance
Area
e-SM Drive model
Free Distance
Above the unit
103..105..107..111..115
> 260mm (10.2 in)
Center-distance between units (to
ensure space for cabling)
103..105..107..111..115
> 260mm (10.2 in)
303..305..307..311..315..322
≥ 300mm (11.8 in)
3.7 Design and layout
Parts and descriptions
The unit can be fitted with the features the application requires.
Figure 12: Open terminal box cover on drive models 103, 105, 107, 111, 115
Table 4: Part description
Position
number
Description
Tightening torque
[Nm]
[in•lbs]
1
Captive Screws
1.2
11
2
Terminal Box Cover
-
-
3
Optional module with strip
-
-
4
IO Cable gland M12 (3x) / M16 (1x)
0.7/2
6.4/18.3
5
M20 Power cable gland
2.7
24.75
Summary of Contents for LOWARA e-SVE
Page 4: ...en Original instructions 4...