en – Original instructions
e-IXPS - Installation, Operation and Maintenance Instructions
19
125-80-.. 125 2765 2485 2240 4340 1470 1050 1330 2243 80 1575 1435 1750 2757 1120 805 910 1652
125-100-.. 125 2765 2485 2240 4340 1470 1050 1330 2243 100 2100 1890 2345 3672 1225 875 1015 1816
150-125-.. 150 3500 3150 2835 5496 1750 1225 1435 2573 125 2485 2240 2765 4340 1470 1050 1330 2243
200-150-.. 200 4690 4200 3780 7343 2275 1610 1855 3348 150 3150 2835 3500 5496 1750 1225 1435 2573
250-200-.. 250 5845 5215 4725 9148 3115 2205 2555 4593 200 4200 3780 4690 7343 2275 1610 1855 3348
300-250-.. 300 7000 6265 5635
10955
4235 3010 3465 6245 250 5215 4725 5845 9148 3115 2205 2555 4593
4.3.4
Auxiliary Connections
NOTE:
Unused or incorrectly used connections may cause malfunction and damage to the unit.
1.
Suction port
2.
Discharge port
3.
G 1/4" recirculation outlet (optional)
4.
G 1/4” suction pressure port
5.
G 1/4" discharge pressure port
6.
G 1/2” drain
4.4
Mechanical seals and auxiliary systems
1.
Find the type of seal by reading the third and second last letters of the identification code.
2.
Follow the instructions and the API PLAN standards in the table based on the type.
Designation Type of seal
API PLAN std
Instructions
S0
Single mechanical seal – unbalanced – without shaft
sleeve
1, 11
Maintenance free mechanical seal
4.5
Electrical connection
4.5.1
Precautions
Electrical measures
DANGER: Electrical hazard
For the electrical connections, make sure to comply with the requirements of the IEC 60079-14
standard.
DANGER: Electrical hazard:
Before starting work, check that the electric power supply is disconnected and locked out, to
avoid unintentional restart of the unit, the control panel and the auxiliary control circuit.