Xylem JABSCO Ballast SuperKing Quick Start Manual Download Page 8

www.xylem.com/jabsco

© 2022 Xylem Inc. All rights reserved

Jabsco is a trademark of Xylem Inc. or one of its subsidiaries

43010-0333 Rev. A 03/2022

Xylem Inc. — USA

17942 Cowan
Irvine, CA 92614

Xylem Inc. — HUNGARY KFT

2700 Cegléd
Külso-Kátai út 41

Xylem Inc. — UK

Harlow Innovation Park,
London Road, Harlow, Essex, CM17 9LX

Xylem Inc. — AUSTRALIA

2/2 Capicure Drive
Eastern Creek, NSW 2766

Xylem Inc. — CHINA

30/F Tower A, 100 Zunyi Road, Shanghai
200051

Warranty:

XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORKMANSHIP FOR A PERIOD OF 1 YEAR. THE WARRANTY IS EXCLUSIVE AND IN 

LIEU OF ANY AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER NATURE RELATING TO THE GOODS PROVIDED 

HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY 

EXPRESSLY DISCLAIMED AND EXCLUDED.  EXCEPT AS OTHERWISE PROVIDED BY LAW, BUYER’S EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH 

OF ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT PAID BY THE 

BUYER HEREUNDER.  IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES,  WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSEQUENTIAL, 

PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS 

OF BUSINESS, LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION.  THIS WARRANTY IS ONLY A REPRESENTATION OF THE COMPLETE LIMITED 

WARRANTY. FOR A DETAILED EXPLANATION, PLEASE VISIT US AT 

www.xylem.com/en-us/support/

, CALL OUR OFFICE NUMBER LISTED, OR WRITE A LETTER TO YOUR 

REGIONAL OFFICE.

AIS (Aquatic Invasive Species) Decontamination Process.

All of our pumps are designed to meet the ABYC standards for the current AIS

Decontamination procedure including low pressure water at 120ºF for 130 seconds.

Please follow current guidelines for the decontamination process.

Summary of Contents for JABSCO Ballast SuperKing

Page 1: ...Ballast SuperKing DC Flexible Impeller Pump ...

Page 2: ...e equipment If the recommended safety notices are not strictly observed it can lead to serious or fatal injuries of personnel and or material damage It is not recommended to run SuperKing pump dry Do not run the pump with a closed or restricted discharge line This pump is not a submersible pump Failure to observe the recommended safety procedures can lead to material damage Only qualified Service ...

Page 3: ...he pump is reversible therefore freshwater or seawater can be transferred from source to ballast and returned from ballast to source To reduce ballast the pump will reverse to pump ballast back over board The same operation is used for ballast transfer between two tanks INSTALLATION PUMP SET UP Verify that all components are present Check the pump unit has not been damaged during transit Ensure in...

Page 4: ... body to motor screws 21 28 lbf ins 2 4 3 1 Nm ELECTRICAL CONFIGURATION AND INSTALLATION 33710 0107 configured with Deutsch DTP04 2P connector Pin 1 Positive Pin 2 Negative It is the responsibility of the installer to per form the correct installation Make all electrical connections in dry loca tions connections in humid environments should be sealed to prevent corrosion Protect the circuit with a...

Page 5: ...ensional Drawings inches mm 5 12 130 3 56 90 4 2 56 65 89 22 5 2 80 71 1 8 98 228 1 18 30 3 58 91 1 99 50 6 1 36 34 45 2 PLCS 1 25 31 75 2 PLCS 3 74 95 64 16 3 Deutsch DTP04 2P Pin 1 Positive Pin 2 Negative ...

Page 6: ...t to ensure self priming The pump can run dry up to 1 minute after running wet for 5 minutes TECHNICAL SPECIFICATIONS The data specified in the above table refers to performance running at the ideal efficiency points on water at 68 F 20 C with battery charged at 12 0Vdc For longer installations fit thicker cables reference ISO 10133 The wire length is the total distance from the battery to the pum...

Page 7: ...tors and cables are in good condition once a month 1 7 2 5 6 3 4 KITS AND ACCESSORIES 33610 0107 Key Part Number Description Qty 1 9328 0202 Kit End Cover 1 2 End Cover O ring 1 3 91004 0090 Kit Screw 12 24 x 375 SL FIL BR 3 per 3 4 98019 0020 Kit Screw 10 32 x 1 2 SL HX BR 3 per 2 5 6303 0007 P Kit Impeller 1 per 2 6 18753 0384 Kit Lip Seal 1 per 1 7 50070 0040 Impeller Removal Tool 1 6303 0007 P...

Page 8: ...CLUDED EXCEPT AS OTHERWISE PROVIDED BY LAW BUYER S EXCLUSIVE REMEDY AND SELLER S AGGREGATE LIABILITY FOR BREACH OFANYOFTHE FOREGOINGWARRANTIESARE LIMITEDTO REPAIRING OR REPLACINGTHE PRODUCTAND SHALLINALLCASES BE LIMITEDTOTHEAMOUNTPAID BYTHE BUYER HEREUNDER IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES WHETHER DIRECT INDIRECT LIQUIDATED INCIDENTAL CONSEQUENTIAL PUNITIVE EXEMPLARYOR SPE...

Reviews: