TROUBLESHOOTING

FAILURE TO DISCONNECT AND LOCKOUT ELECTRICAL    

 

 

 

 

POWER BEFORE ATTEMPTING ANY SERVICE CAN CAUSE  

 

 

 

 

 

SHOCK, BURNS OR DEATH.

SYMPTOM 

PROBABLE CAUSE 

RECOMMENDED ACTION

MOTOR NOT RUNNING 

Motor thermal protector tripped. 

Allow motor to cool. Insure minimum pump   

 

 

 

submergence. Clear debris from casing and impeller.

 

Open circuit breaker or blown fuse.  Determine cause, call a qualified electrician.

 

Pump impeller binding or jammed.  Check motor amp draw. If two or more times higher    

 

 

than listed on pump nameplate, impeller is locked, 

a) Manual operation 

Power cable is damaged. 

motor bearings or shaft is damaged. Clear     

 

 

Inadequate electrical connection 

debris from casing and impeller, consult with dealer.

 

in control panel. 

 

 

Resistance between power leads and ground should   

b) Automatic operation 

No neutral wire 

read infinity. If any reading is incorrect, call a    

 

connected to control panel. 

qualified electrician.

 

Inadequate electrical connection  

Inspect control panel wiring. Call a qualified    

 

 

in control panel. 

electrician.

 

Defective liquid level switch. 

With switch disconnected, check continuity while  

 

 

 

activating liquid level switch. Replace switch, as  

 

  

required.

 

Insufficient liquid level to  

Allow liquid level to rise 3" to 4" (76 mm - 101 mm)    

 

activate controls. 

above turn-on level.

 

Liquid level cords tangled. 

Untangle cords and insure free operation.

PUMP WILL NOT  

Liquid level cords tangled. 

Untangle cords and insure free operation.

TURN OFF
 

Pump is air locked. 

Shut off pump for approximately one minute, then    

 

 

restart. Repeat until air lock clears. If air locking  

 

 

 

persists in a system with a check valve, a 

3

16

" (4.8 mm)   

 

 

hole may be drilled in the discharge pipe approximately 

 

 

2" (51 mm) above the discharge connection.

 

Influent flow is matching pump’s  

Larger pump may be required. 

 

 

 

 

discharge capacity.

LITTLE OR NO LIQUID  

Check valve installed backwards,  

Check flow arrow on valve and check valve    

DELIVERED BY PUMP 

plugged or stuck closed. 

operation.

 

Excessive system head. 

Consult with dealer.

 

Pump inlet plugged. 

Inspect and clear as required.

 

Improper voltage or wired  

Check pump rotation, voltage and wiring.    

 

 

incorrectly. 

Consult with qualified electrician.

 

Pump is air locked. 

See recommended action, above.

 

Impeller is worn or damaged. 

Inspect impeller, replace as required.

 

Liquid level controls defective  

Inspect, readjust or replace as required. 

 

 

 

or improperly positioned.

PUMP CYCLES  

Discharge check valve inoperative. 

Inspect, repair or replace as required.

CONSTANTLY 

Sewage containment area too small.  Consult with dealer.

 

Liquid level controls defective or  

Inspect, readjust or replace as required. 

 

 

 

improperly positioned.

 

Influent excessive for this size  

Consult with dealer. 

 

 

 

 

 pump.

NOTE:

 If circuit breaker 

“OPENS” repeatedly,  

DO NOT

 reset. Call  

qualified electrician.

NOTE:

 Check the pump in 

manual mode first to con

-

firm operation. If pump 

operates, the automatic 

control or wiring is at fault. 

If pump does not operate, 

see above.

WARNING

Hazardous 
voltage

Summary of Contents for GOULDS WEHT0311M

Page 1: ...High Temp Sump Pump INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM248R03 ...

Page 2: ...UBJECT PAGE Introduction 3 Safety Instructions 3 Performance and Motor Details 3 Pre Installation Checks 3 Lifting of Pump 4 Optional Guide Rail or Lift Out System 4 Piping 4 Wiring and Grounding 4 Selecting and Wiring Pump Control Panels and Switches 4 Installation 5 Operation 5 Float Switch and Panel Chart 6 Insulation Resistance Readings 7 Engineering Data 7 Troubleshooting 8 Typical Installati...

Page 3: ...nal injury or equip ment damage Failure to follow manufacturer s installa DANGER WARNING CAUTION tion instructions may result in electrical shock fire hazard personal injury or death damaged equipment provide unsatisfactory performance and may void manufacturer s warranty Standard units are not designed for use in swimming pools open bodies of water hazardous liquids or where flammable gases exist...

Page 4: ... valve matched to the solids handling capability of the pump to prevent fluid backflow Backflow can allow the pump to turbine backwards and may cause premature seal and or bear ing wear If the pump is turning backwards when it is called on to start the increased torque may cause dam age to the pump motor and or motor shaft and some single phase pumps may actually run backwards Install an adequatel...

Page 5: ...AND WIRING PUMP CONTROL PANELS AND SWITCHES FLOAT SWITCH TYPES High Temp floats can be purchased for High Temp ap plications They are normally open NO for pump down operations These wide angle pump down switches may be used as direct connected pump switches or as control switches SETTING THE FLOAT SWITCHES There are no absolute rules for where to set the float switches it varies from job to job Su...

Page 6: ...t place pump switch es in the Au tomatic position and Control Switch in ON position The system is now ready for automatic operation Explain the operation of the pumps controls and alarms to the end user Leave the paperwork with the owner or at the control panel if in a dry secure location FLOAT SWITCH AND PANEL CHART The purpose of this chart is to show the required switch quantities and the funct...

Page 7: ... are based on readings taken with a megohmmeter with a 500V DC output Readings may vary using a lower voltage ohmmeter consult factory if readings are in question ENGINEERING DATA PUMP OPERATION Figure 2 Determining Pumping Range Figure 1 Pumpmaster and Pumpmaster Plus Hard Wired Engineering data for specific models may be found in your catalog and on our website address is on the cover Control pa...

Page 8: ...velcordstangled Untanglecordsandinsurefreeoperation TURNOFF Pumpisairlocked Shutoff pumpforapproximatelyoneminute then restart Repeatuntilairlockclears If airlocking persistsinasystemwithacheckvalve a3 16 4 8mm holemaybedrilledinthedischargepipeapproximately 2 51mm abovethedischargeconnection Influentflowismatchingpump s Largerpumpmayberequired dischargecapacity LITTLEORNOLIQUID Checkvalveinstalle...

Page 9: ...9 TYPICAL INSTALLATIONS Typical Effluent Sewage and Dewatering Pump Installations ...

Page 10: ...10 NOTES ...

Page 11: ...11 NOTES ...

Page 12: ...oper electrical protection or g damaged resulting from the use of accessory equipment not sold or approved by Seller In any case of products not manufactured by Seller there is no warranty from Seller however Seller will extend to Buyer any warranty received from Seller s supplier of such products Goulds Water Technology Policy Concerning Online Sales to Consumers Homeowners using the Internet to ...

Reviews: