LIMITED CONSUMER WARRANTY

For goods sold for personal, family or household purposes, Seller warrants the goods purchased hereunder (with the exception of membranes, 

seals, gaskets, elastomer materials, coatings and other “wear parts” or consumables all of which are not warranted except as otherwise provided 

in the quotation or sales form) will be free from defects in material and workmanship for a period of one (1) year from the date of installation or 

eighteen (18) months from the product date code, whichever shall occur first, unless a longer period is provided by law or is specified in the product 
documentation (the “Warranty”).

Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer, either repair or replace any product which fails to conform 
with the Warranty provided Buyer gives written notice to Seller of any defects in material or workmanship within ten (10) days of the date when any 

defects or non-conformance are first manifest. Under either repair or replacement option, Seller shall not be obligated to remove or pay for the 

removal of the defective product or install or pay for the installation of the replaced or repaired product and Buyer shall be responsible for all other 
costs, including, but not limited to, service costs, shipping fees and expenses. Seller shall have sole discretion as to the method or means of repair 
or replacement. Buyer’s failure to comply with Seller’s repair or replacement directions shall terminate Seller’s obligations under this Warranty and 
render this Warranty void. Any parts repaired or replaced under the Warranty are warranted only for the balance of the warranty period on the parts 
that were repaired or replaced. The Warranty is conditioned on Buyer giving written notice to Seller of any defects in material or workmanship of 

warranted goods within ten (10) days of the date when any defects are first manifest.

Seller shall have no warranty obligations to Buyer with respect to any product or parts of a product that have been: (a) repaired by third parties other 
than Seller or without Seller’s written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or physical damage; (c) used in a 
manner contrary to Seller’s instructions for installation, operation and maintenance; (d) damaged from ordinary wear and tear, corrosion, or chemical 

attack; (e) damaged due to abnormal conditions, vibration, failure to properly prime, or operation without flow; (f) damaged due to a defective 

power supply or improper electrical protection; or (g) damaged resulting from the use of accessory equipment not sold or approved by Seller. In any 
case of products not manufactured by Seller, there is no warranty from Seller; however, Seller will extend to Buyer any warranty received from Seller’s 
supplier of such products.

Goulds Water Technology Policy Concerning Online Sales to Consumers.

 Homeowners using the Internet to locate information regarding 

residential water systems, residential wastewater systems, controls and tanks may discover several sites offering a direct-to-consumer purchasing 

opportunity.  Residential water and wastewater systems are mission critical applications and are designed to be installed by qualified professionals.  

Goulds Water Technology has an extensive nationwide network of distributors and dealers, including authorized resellers.  For a complete view of 
Goulds Water Technology recognized distributors, dealers and authorized resellers, please refer to our locator at: http://goulds.com/sales-service/

No warranty is offered on Goulds Water Technology equipment purchased over the Internet, including web-based options from unauthorized 
retailers. This policy is necessary to ensure that Goulds Water Technology equipment is installed properly, in compliance with applicable laws, rules 
and codes, in a manner that addresses safety concerns and the proper performance of Goulds Water Technology equipment. 

THE FOREGOING WARRANTY IS PROVIDED IN PLACE OF ALL OTHER EXPRESS WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING BUT 
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE (1) 
YEAR FROM THE DATE OF INSTALLATION OR EIGHTEEN (18) MONTHS FROM THE PRODUCT DATE CODE , WHICHEVER SHALL OCCUR FIRST. 
EXCEPT AS OTHERWISE REQUIRED BY LAW, BUYER’S EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE 
FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT 
PAID BY THE BUYER FOR THE DEFECTIVE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER 
DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED 
TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF 
OPPORTUNITY OR LOSS OF REPUTATION.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow 

the exclusion or limitation of incidental or consequential damages, so the above exclusions may not apply to you. This warranty gives you specific 

legal rights, and you may also have other rights which may vary from state to state. 

To make a warranty claim, check first with the dealer from whom you purchased the product or visit www.xyleminc.com for the name and location of 

the nearest dealer providing warranty service.

Summary of Contents for GOULDS WEHT0311M

Page 1: ...High Temp Sump Pump INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM248R03 ...

Page 2: ...UBJECT PAGE Introduction 3 Safety Instructions 3 Performance and Motor Details 3 Pre Installation Checks 3 Lifting of Pump 4 Optional Guide Rail or Lift Out System 4 Piping 4 Wiring and Grounding 4 Selecting and Wiring Pump Control Panels and Switches 4 Installation 5 Operation 5 Float Switch and Panel Chart 6 Insulation Resistance Readings 7 Engineering Data 7 Troubleshooting 8 Typical Installati...

Page 3: ...nal injury or equip ment damage Failure to follow manufacturer s installa DANGER WARNING CAUTION tion instructions may result in electrical shock fire hazard personal injury or death damaged equipment provide unsatisfactory performance and may void manufacturer s warranty Standard units are not designed for use in swimming pools open bodies of water hazardous liquids or where flammable gases exist...

Page 4: ... valve matched to the solids handling capability of the pump to prevent fluid backflow Backflow can allow the pump to turbine backwards and may cause premature seal and or bear ing wear If the pump is turning backwards when it is called on to start the increased torque may cause dam age to the pump motor and or motor shaft and some single phase pumps may actually run backwards Install an adequatel...

Page 5: ...AND WIRING PUMP CONTROL PANELS AND SWITCHES FLOAT SWITCH TYPES High Temp floats can be purchased for High Temp ap plications They are normally open NO for pump down operations These wide angle pump down switches may be used as direct connected pump switches or as control switches SETTING THE FLOAT SWITCHES There are no absolute rules for where to set the float switches it varies from job to job Su...

Page 6: ...t place pump switch es in the Au tomatic position and Control Switch in ON position The system is now ready for automatic operation Explain the operation of the pumps controls and alarms to the end user Leave the paperwork with the owner or at the control panel if in a dry secure location FLOAT SWITCH AND PANEL CHART The purpose of this chart is to show the required switch quantities and the funct...

Page 7: ... are based on readings taken with a megohmmeter with a 500V DC output Readings may vary using a lower voltage ohmmeter consult factory if readings are in question ENGINEERING DATA PUMP OPERATION Figure 2 Determining Pumping Range Figure 1 Pumpmaster and Pumpmaster Plus Hard Wired Engineering data for specific models may be found in your catalog and on our website address is on the cover Control pa...

Page 8: ...velcordstangled Untanglecordsandinsurefreeoperation TURNOFF Pumpisairlocked Shutoff pumpforapproximatelyoneminute then restart Repeatuntilairlockclears If airlocking persistsinasystemwithacheckvalve a3 16 4 8mm holemaybedrilledinthedischargepipeapproximately 2 51mm abovethedischargeconnection Influentflowismatchingpump s Largerpumpmayberequired dischargecapacity LITTLEORNOLIQUID Checkvalveinstalle...

Page 9: ...9 TYPICAL INSTALLATIONS Typical Effluent Sewage and Dewatering Pump Installations ...

Page 10: ...10 NOTES ...

Page 11: ...11 NOTES ...

Page 12: ...oper electrical protection or g damaged resulting from the use of accessory equipment not sold or approved by Seller In any case of products not manufactured by Seller there is no warranty from Seller however Seller will extend to Buyer any warranty received from Seller s supplier of such products Goulds Water Technology Policy Concerning Online Sales to Consumers Homeowners using the Internet to ...