background image

3

CONGRATULATIONS

You are now the owner of a Goulds Water Technology 

pump. This pump was carefully inspected and subjected 

to final tests before releasing for shipment. In order to 

assure maximum performance, please follow the simple 

instructions in this manual.

RECOMMENDED PRECAUTIONS

  1. Avoid system pressures that may exceed the maxi-

mum working pressure of the pump.

  2. Should the fluid temperature rise more than 50ºF. 

above ambient, expansion joints must be installed on 

both the suction and discharge ports to relieve any 

stress on the pump casing.

  3. All electrical wiring of the pump installation must be  

done by a licensed electrician who will observe all 

national and local electrical codes. All motors require 

a magnetic starter with current overload protection.

  4. No modifications, additions or deletions should be 

made to the pump, without prior approval of the 

factory.

  5. In systems where shock wave pressures may be gener-

ated, protective devices such as check valves/gate 

valves, etc., must be installed on the discharge line 

to prevent shock pressures from entering the pump 

casing.

  6. In systems containing discharge check valves, gate 

valves, etc., the pump will not prime against a closed 

valve. Check the discharge valves making sure they 

are open before attempting to prime the pump. If 

there is a possibility of air being entrapped in the 

pump casing, install an automatic venting device to 

bleed off the air.

  7. This pump is designed primarily for water use. Before 

pumping other liquids, read carefully the CAUTION 

below.

  8. Overheated pumps are dangerous. Burns or explosion 

could occur due to steam pressure. Operating pumps 

with suction and discharge closed is one cause of se-

vere overheating. If overheating of the pump occurs: 

1. Stop pump immediately, 2. Allow pump to cool, 3. 

Slowly and cautiously vent pump.

  9. Drain casing completely when servicing pumps han-

dling volatile or harmful liquids.

10. Do not use in a combustible atmosphere.
11. Make daily checks of the tightness of suction and 

discharge pipe, drain, filter plug and pump gaskets. 

Operation should not proceed until all of the above 

items have been checked and are tight.

12. After servicing the pump, always install the coupling  

guards, belt guards and other safety devices as origi-

nally found prior to disassembly.

The performance of Goulds Water 

Technology are based upon clear, cold, 

fresh water with suction conditions as shown on the 

performance curve. If used to pump other liquids, pump 

performance may differ from rated performance based 

on the different specific gravity, temperature, viscosity, 

etc. of the liquid being pumped. A standard pump may 

not be safe for pumping all types of liquids, such as toxic, 

volatile or chemical liquids, or liquids under extreme 

temperatures or pressures. Please consult your Goulds 

Water Tehcnology catalog as well as local codes and 

general references to determine the appropriate pumps 

for your particular application. Since it is impossible 

for us to anticipate every application of a Goulds Water 

Tehcnology pump, if you plan to use the pump for a 

non-water application, consult Goulds Water Tehcnology 

beforehand to determine whether such application may 

be proper or safe under the circumstances. Failure to do 

so could result in property damage or personal injury.

OPERATING INSTRUCTIONS

GENERAL

• Our shipping container has been specifically designed 

to prevent transit damage. However, any indications 

of damage or shortage should be carefully noted on 

the delivery ticket and a claim filed promptly with the 

carrier.

PROPER LOCATION

• By placing your pump on a firm, level foundation or 

between firmly supported pipelines, you reduce harm-

ful vibrations and unnecessary noises.

• While EV series pumps are self-priming and may be 

located above the source of liquid supply, best pump 

operation is obtained by locating the pump as close as 

possible to the liquid being handled, keeping in mind a 

pump can push liquid more effectively than it can pull 

or draw liquid. Provide the necessary space around the 

pump for future inspection and servicing of the unit.

PIPING

• All piping should be independently supported to elimi-

nate excessive strain on the pump. Avoid unnecessary 

friction losses. Keep your piping as short as possible 

and use the fewest possible elbows and fittings. Pipe 

joint compound that will not dissolve in the liquid 

being pumped should be used on all joints. Gate valves 

combined with unions or flanges, on both sides of the 

pump, will facilitate pump removal without disturbing 

the piping. It is occasionally advantageous to use suc-

tion pipe one size larger than that for which the pipe 

is fitted. Eccentric reducers should be used to change 

pipe sizes.

STRAINER ADVISABLE

• Protect your investment. Install a strainer on the suc-

tion line. This will eliminate clogging of the pump, 

poor performance and excessive wear. A 16 mesh 

strainer submerged one foot below the liquid level is 

adequate for EV series pumps. In-line strainers are 

available from your Goulds Water Technology dealer. 

Piping that has a continuous rise will facilitate draining 

the system.

VALVES

• Install a check valve on the discharge side of the pump. 

This will prevent high surge back pressures from 

damaging the pump. If the pump is disconnected this 

check valve will prevent the liquid from draining the 

discharge line.

• Some installations may require the throttling of the 

pump. Gate valves may be used on the discharge side. 

Place the check valve between pump and gate valve.

CAUTION

Summary of Contents for Goulds Marlow Series

Page 1: ...Retain Manual for Reference Marlow Series 20EVP INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM078 ...

Page 2: ...tenance 4 Warning 4 Caution 4 Instructions for Licensed Electricians 4 Troubleshooting Guide 5 Repair Parts 6 Limited Warranty 8 Please fill in data from your pump nameplate Warranty information is on page 8 Pump Model Serial Number Dealer Dealer s Phone Number Date of Purchase Installation Date Owner s Information Owner s Information ...

Page 3: ... pumping all types of liquids such as toxic volatile or chemical liquids or liquids under extreme temperatures or pressures Please consult your Goulds Water Tehcnology catalog as well as local codes and general references to determine the appropriate pumps for your particular application Since it is impossible for us to anticipate every application of a Goulds Water Tehcnology pump if you plan to ...

Page 4: ...nts have been in corporated into our self lubricating shaft seal The liquid being pumped cools and lubricates the seal therefore the pump should never be run dry A seal well vent has been provided to protect the electric motor from liquid damage should the seal leak DO NOT plug this vent If leakage becomes excessive replace the seal assembly MAINTENANCE If your pump is not used for a few days drai...

Page 5: ...eakage Worn seal Replace seal From Seal Well Vent Will Not Worn seal Replace seal Hold Prime Suction lift too high Relocate pump closer to supply Air leak in suction line Fix leak Performance Poor Worn impeller or seal Replace with new impeller or seal Suction lift too high Relocate pump closer to supply Low Flow Motor not up to speed low voltage Larger lead wires Or Pressure Air leak Tighten all ...

Page 6: ...TANT How to use the drawing to order parts The above grouping of parts illustrations cover many different Goulds Water Technology models including your own pump The table on the left page indicates the name of each part Should you need a replacement refer to the drawing locate the part that matches your pump part Contact your local Goulds Water Technology dealer and supply him with the key number ...

Page 7: ...7 NOTES ...

Page 8: ...uipment d Consequential damages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between Goulds Water Technology and the dealer in purchases consignments or contracts for sale of the subject...

Page 9: ...Mantenga este manual para consultas Serie Marlow 20EVP INSTRUCCIONES DE INSTALACIÓN OPERACIÓN Y MANTENIMIENTO MANUAL DE INSTRUCCIÓN IM078 ...

Page 10: ...trucciones para electricistas con licencia 12 Guía de solución de fallas 13 Refacciones 14 Garantía limitada 16 Favor de copiar a continuación los datos de la placa de datos de su bomba La información de la garantía está en la página 16 Número de modelo de la bomba Número de serie Distribuidor Teléfono del dist Fecha de compra Fecha de instalación Información del propietario Información del propie...

Page 11: ... bombeo de agua fresca fría y transparente con las condiciones de succión que se muestran en la curva de desempeño Si usa la bomba para otros líquidos el desempeño de la misma puede diferir del nominal en base a la diferencia de gravedad temperatura viscosidad etc Puede ser que una bomba estándar no sea segura para bombear todos los tipos de líquidos como tóxicos volátiles o químicos o líquidos ba...

Page 12: ...r todo el líquido del tanque de la bomba Esto evitará que el hielo que se puede formar rompa el tanque o partes internas Para mantener un desempeño excelente de la bomba siga las instrucciones de almacenamiento del fabricante del motor OPERACIÓN LUBRICACIÓN Nuestro sello de eje autolubricante lleva los últimos avances de la ingeniería El líquido que se va a bombear enfría y lubrica el sello por lo...

Page 13: ...l pozo No mantiene la Sello gastado Reemplace el sello bomba cebada Elevación de succión muy alta Reubique la bomba más cerca del suministro Fuga de aire en la línea de succión Escape del arreglo Pobre desempeño Sello o impulsor gastado Reemplace el sello o impulsor por uno nuevo Elevación de succión muy alta Reubique la bomba más cerca del suministro Flujo o presión bajos El motor no alcanza la v...

Page 14: ...ORTANTE Cómo usar el dibujo para solicitar partes de repuesto Las ilustraciones anteriores de grupos de partes cubren diferentes modelos de Goulds Water Technology incluyendo la bomba de usted La tabla en la página izquierda indica el nombre de cada parte Si necesitara cambiar una de ellas consulte el dibujo y localice la parte que coincida con la parte de su bomba Contacte a su distribuidor local...

Page 15: ...15 NOTAS NOTAS ...

Page 16: ...quipo reemplazado d daños emergentes de cualquier naturaleza y e el reembolso de cualquier pérdida causada por la interrupción del servicio A los fines de esta garantía los términos Distribuidor Comerciante y Cliente se definen como sigue 1 Distribuidor es aquel individuo sociedad corporación asociación u otra entidad jurídica que opera entre Goulds Water Technology y el comerciante para la compra...

Page 17: ...À conserver à titre consultatif Marlow série 20EVP DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN MANUEL D UTILISATION IM078 ...

Page 18: ...ens 20 Diagnostic des anomalies 21 Liste de pièces de rechange 22 Garantie limitée 24 Inscrire ci dessous les informations pertinentes indiquées sur la plaque signalétique de la pompe La garantie se trouve en page 24 No de modèle de la pompe No de série de la pompe Détaillant No de tél du détaillant Date d achat Date d installation Informations pour le propriétaire Informations pour le propriétair...

Page 19: ...d une pompe standard peut être risqué si le liquide est très chaud toxique volatile PRÉCAUTIONS RECOMMANDÉES ATTENTION d origine chimique ou sous une très forte pression Il vaut mieux consulter le catalogue Goulds Water Technology ainsi que les codes locaux et les ouvrages de référence généraux pour sélectionner la pompe convenant à un usage particulier Goulds Water Technology ne peut prévoir tous...

Page 20: ... entreposage LUBRIFICATION La garniture mécanique autolubrifiante est le fruit des derniers progrès techniques Étant donné que le liquide pompé refroidit et lubrifie la garniture la pompe ne doit jamais fonctionner à sec L orifice de fuite du logement de garniture protégera le moteur électrique du liquide s il y a fuite de la garniture NE PAS boucher l orifice Si la garniture fuit trop la remplace...

Page 21: ...ture mécanique usée Remplacer la garniture désamorce Hauteur d aspiration excessive Rapprocher la pompe de sa source de liquide Air entrant dans la tuyauterie d aspiration Colmater la fuite Le rendement est Roue ou garniture mécanique usée Poser une roue ou une garniture neuve faible Hauteur d aspiration excessive Rapprocher la pompe de sa source de liquide Le débit ou la pression Moteur trop lent...

Page 22: ...ice critique pièces de rechange pour l exportation et stocks du distributeur recommandés IMPORTANT Mode de commande des pièces La liste de pièces et le dessin figurant dans la présente page s appliquent à divers modèles de pompes Goulds Water Technology y compris la 20EVP Au besoin se servir de la liste et du dessin pour trouver le numéro et le nom d une pièce à remplacer puis les indiquer au déta...

Page 23: ...23 NOTES ...

Page 24: ...e soit e ni les pertes découlant de la panne Aux fins de la garantie les termes ci dessous sont définis comme suit 1 Distributeur signifie une personne une société de personnes une société de capitaux une association ou autre entité juridique servant d intermédiaire entre Goulds Water Tech nology et le détaillant pour les achats les consignations ou les contrats de vente des pompes en question 2 D...

Reviews: