Service item
Action
Zinc anodes
If applicable, replace the zinc anodes.
Anodes are replaced when the anode mass is reduced to a selected fraction of its
initial mass. The recommended interval for the selection fraction is 0.25–0.50 (25–
50%).
8.2.2 Major overhaul
The basic repair kit includes O-rings, seals, and bearings.
For a major overhaul, do the following in addition to the tasks listed under Inspection.
Service item
Action
Support and main bearing
Replace the bearings with new bearings.
Mechanical seal
Replace with new seal units.
8.3 Drain the liquid from the stator housing
1
WS009970A
Item
Label
Description
1
INSP
Inspection plug for inspection and drainage
Figure 5: Inspection plug
1. Remove the inspection plug.
2. Pump out the liquid.