7. Remove the impeller key.
8. Remove pins and O-rings from each casing wear ring.
6.5.8 Pump disassembly for pumps with integrated stuffing box design
The disassembly process for pumps with an integrated stuffing box may be considered
identical to the drop-in stuffing box design with a few minor differences. Please note
differences outlined below and then refer to
Pump disassembly for pumps with drop-in
stuffing box and sleeve over shaft (dry shaft) design
pumps with drop-in stuffing box and sleeveless shaft (wet shaft) design
on page 61. Follow
all safety procedures outlined in
1. Before separating the upper and lower casing, remove both pump shaft guards, all
flush lines, and remove the top two seal gland bolts from the upper casing on both
sides of the pump.
Note: For packing configurations, the flush line ports run through the upper casing just
above the seal chamber.
6 Maintenance
64
e-XC INSTRUCTION MANUAL