5. Use pre-installed jacking screws to separate upper and lower casing halves.
6. Remove upper casing via integrated lifting lugs located atop the upper casing.
NOTE: Follow lifting precautions and instructions according to
on page 7. As a general rule, only use lifting lugs or eyebolts to lift the component they
are attached to. Do not lift the entire pump by its lifting lugs.
7. Unfasten shaft guard bolts and remove both shaft guards.
8. If using oil for bearing lubrication, drain oil from bearing housing by unfastening plugs
located on the undersides of both bearing housings.