![Xylem Bell & Gossett e-1510 Series Instruction Manual Download Page 11](http://html1.mh-extra.com/html/xylem/bell-and-gossett-e-1510-series/bell-and-gossett-e-1510-series_instruction-manual_3982470011.webp)
Pump type
Lifting method
A base-mounted pump.
Lifting the pump less motor or the pump, motor, & baseplate should be done by
using lifting lugs provided on the baseplate, or by utilizing a forklift under the
entire unit. Always take extra precaution to ensure the weight is balanced & equally
distributed across both forks. When the baseplate of the assembly is structural
channel construction, the pump and base plate should be set in place first. The
motor should then be separately lifted & mounted to the unit.
Examples
Figure 1: Example of a proper lifting method using lifting lugs
Figure 2: Lift using a forklift
2.3 Storage requirements
If the unit will not to be installed and put into operation immediately upon arrival at the
site, or for an extended shutdown after the unit is in operation, the following requirements
for short-term storage apply:
• Store in a covered and dry location.
• Store the unit free from excessive cold or heat (below 32°F and above 110°F), dirt, and
vibration.
• Rotate the shaft by hand several times (10–15 turns) at least every 30 days.
For initial storage longer than three months, or for pump shut down after being in
operation longer than three months, contact your local sales and service representative
for long-term storage guidelines.
2 Transportation and Storage
Series e-1510 INSTRUCTION MANUAL
9
Summary of Contents for Bell & Gossett e-1510 Series
Page 1: ...INSTRUCTION MANUAL P2001406 Rev E Series e 1510...
Page 2: ......