Xylem 10SHV Installation, Operation And Maintenance Instructions Download Page 3

3

SAFETY INSTRUCTIONS                  

TO AVOID SERIOUS OR FATAL PERSONAL 

INJURY OR MAJOR PROPERTY DAMAGE, READ 

AND FOLLOW ALL SAFETY INSTRUCTIONS IN 

MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE 

INSTALLATION AND OPERATION OF THIS UNIT 

AND MUST BE KEPT WITH THE PUMP.

This is a SAFETY ALERT SYMBOL

When you see this symbol on the pump 

or in the manual, look for one of the 

following signal words and be alert 

to the potential for personal injury or 

property damage.
Warns of hazards that WILL cause 

serious personal injury, death or major 

property damage.
Warns of hazards that CAN cause 

serious personal injury, death or major 

property damage.
Warns of hazards that CAN cause per-

sonal injury or property damage.

 NOTICE:  INDICATES SPECIAL INSTRUCTIONS  

 WHICH ARE VERY IMPORTANT AND  

 MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS 

AND WARNINGS PRIOR TO PERFORMING ANY 

WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

UNIT NOT DESIGNED FOR USE 

WITH HAZARDOUS LIQUIDS OR 

FLAMMABLE GASES. THESE  

FLUIDS MAY BE PRESENT IN  

CONTAINMENT AREAS.

NOTICE: INSPECT UNIT FOR DAMAGE AND 

REPORT ALL DAMAGE TO THE CARRIER OR 

DEALER IMMEDIATELY.

DESCRIPTION and SPECIFICATIONS:

The NPV and SHV Series pumps are vertically immersed, 

end-suction designed pumps for general liquid transfer 

service, machine tool coolant, parts washer, filtration, 

waste treatment and OEM applications. Liquid-end con-

struction is all AISI 300 series stainless steel.
These pumps are not designed for applications requiring 

ANSI, FDA or NSF ratings and are not recommended for 

use in highly abrasive services such as grinding.
Impellers are available in enclosed and open configura-

tions depending on the model. Enclosed impeller versions 

of the NPV are fitted with a diffuser for high efficiency 

and for negligible radial shaft loading.
NPV units have NEMA 56J motors with C-face mount-

ing and threaded shaft extensions. SHV units have 

NEMA standard JM frame motors.

ENGINEERING DATA

Maximum Liquid Temperature:  250° F (120° C)
Maximum Working Pressure: 

NPV 125 psi (9 bars)

 

SHV 230 psi (15 bars)

Starts per hour: 20 - Evenly distributed

INSTALLATION

NOTICE: UNIT CAN BE INSTALLED IN VERTICAL 

ORIENTATION ONLY. DO NOT INSTALL WITH 

MOTOR BELOW PUMP.

Unit may be mounted directly to a tank top or the optional 

Goulds Water Technology mounting plate may be utilized.
Minimum and maximum liquid levels must be main-

tained for proper pump operation. Refer to Dimensions 

page for details.
Allow adequate space for servicing and ventilation.  

Protect from freezing or flooding.

PIPING

Piping should be no smaller than the pump discharge and 

suction connections and kept as short as possible, avoid-

ing unnecessary fittings to minimize friction losses.
All piping MUST be independently supported and 

MUST NOT place any piping loads on the pump.
NOTICE: DO NOT FORCE PIPING INTO PLACE  

AT PUMP SUCTION AND DISCHARGE  

 

CONNECTIONS.

All joints MUST be air tight. Use 3-4 wraps of Teflon™ 

tape to seal threaded connections on NPV Series.
SHV Series pumps use standard ANSI 150# raised face 

flanges.

PIPING - SUCTION
Suction piping is not required for typical installation of 

unit.
Suction intake should be above the minimum distance 

from tank bottom: NPV = 2", SHV = 4". Tank must be 

kept free of debris.
Use a foot valve only when necessary to hold prime 

during intermittent service where tank liquid level does 

not return to minimum depth before pump is re-started. 

Refer to dimensions page for details.

NOTICE: IN ALL CASES, THE BEARING MUST BE 

SUBMERGED IN LIQUID AT START-UP.

To avoid air pockets, no part of suction piping should be 

higher than pump suction connections.

PIPING - DISCHARGE
Install a check valve suitable to handle the flow, liquids 

and to prevent backflow. After the check valve, install an 

appropriately sized gate valve to be used to regulate the 

pump capacity, pump inspection and for maintenance.

DANGER

WARNING

CAUTION

WARNING

Hazardous fluids

can cause fire,

burns or death.

Summary of Contents for 10SHV

Page 1: ...NPV SHV Model SHV and NPV INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM101...

Page 2: ...mbly 5 SHV Reassembly 5 Repair Parts 7 NPV Pump Dimensions Weights and Specifications 9 NPV Optional Mounting Accessories 9 SHV Pump Dimensions Weights and Specifications 10 SHV Optional Mounting Acce...

Page 3: ...eaded shaft extensions SHV units have NEMA standard JM frame motors ENGINEERING DATA Maximum Liquid Temperature 250 F 120 C Maximum Working Pressure NPV 125 psi 9 bars SHV 230 psi 15 bars Starts per h...

Page 4: ...necessary Follow the motor manu facturer s recommendations for maintenance If pump performance degrades due to excessive leakage inspect pump bearing bushing and shaft for excessive wear Replace as n...

Page 5: ...r Remove the mounting plate and motor leg from pump and motor LIQUID END NOTE PRIOR TO DISASSEMBLY PLEASE NOTE RE LATIONSHIP OF PUMP CASING PUMP PLATE MOTOR PLATE AND SUPPORT TUBE WHEN PUMP IS REASSEM...

Page 6: ...e 11 Carefully position pump mounting plate assembly and slide into open end of pump support 12 Insert 3 bolts and tighten to 17 ft lbs Apply 1 drop of LOCTITE 243 to each bolt prior to tightening 13...

Page 7: ...304 SS 12A 1 Shaft Ceramic Coated AISI 304 SS Item Quantity Description Material 13 1 Internal Snap Ring Stainless Steel 14 1 Bushing Nitronic 60 SS 15A 1 Bearing Viton 15B 1 Bearing Carbon 15C 1 Bea...

Page 8: ...g 300 Series SS 9 1 Shaft Extension 300 Series SS 10 1 Tube 300 Series SS 11 6 Bolt Tube 300 Series SS 12 1 Pump Mounting Plate 300 Series SS 13A 1 Bearing Viton 13B 1 Bearing Carbon 13C 1 Bearing EPR...

Page 9: ...weightsinpounds Dimensionesenpulgadas pesos en libras ODP abrit ouverturesdeventilationprot g es TEFC ferm autoventil EXP antid f lagrant ODP TEFC ODP TEFC EXP EXP 1 Phase Monof sicos 1 3 Phase Trif s...

Page 10: ...Discharge Descarga DC max N R Ref R Ref R r f Poids max pompe seule Pompe Aspiration Refoulement 14 24 14 24 14 24 10SHV 1 x 2 8 2 1 71 8 31 8 55 8 149 16 249 16 83 93 9SHV 1 x 2 6 63 8 5 75 85 4SHV...

Page 11: ...2 po DE DIAM POUR LES CARCASSES DE MO TEUR 254JM ET 256JM 17 00 17 00 MOUNTING PLATE 3 8 PLATE STEEL PLACA DE MONTAJE PLACA DE ACERO DE 3 8 PLAQUE DE FIXATION EN ACIER 3 8 CLEARANCE HOLE AGUJERO DE PA...

Page 12: ...ler who believes that a warranty claim exists must contact the authorized Goulds Water Technology distributor from whom the pump was purchased and furnish complete details regarding the claim The dist...

Page 13: ...NPV SHV MANUAL DE INSTRUCCI N IM101 Modelos SHV y NPV INSTRUCCIONES DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO...

Page 14: ...la Serie SHV 18 Partes de repuesto 19 Bomba NPV Dimensiones Pesos y Especificaciones 9 Accesorios de Montaje Opcionales 9 Bomba SHV Dimensiones Pesos y Especificaciones 10 Accesorios de Montaje Opcion...

Page 15: ...para aplicar una carga insignificante del eje radial PELIGRO ADVERTENCIA PRECAUCI N ADVERTENCIA Los fluidos peligrosos pueden causar incendios quemaduras o la muerte Las unidades NPV tienen motores NE...

Page 16: ...IMPULSOR CALIENTE ADVERTENCIA Un voltaje peligroso puede producir golpes el ctricos quemaduras o la muerte Para evitar las bolsas de aire ninguna parte de la tuber a de succi n debe estar situada m s...

Page 17: ...el eje con una llave de 9 16 pulg para que no gire instale el impulsor gir ndolo en sentido HORARIO asegur ndose de que el impulsor se asiente firmemente contra el eje 8 Aplique la cartilla del LOCTI...

Page 18: ...el perno con la arandela y torsi nelo a 17 pie lbs NOTA ASEG RESE DE QUE EL SELLO DE TAZ N EN U PERMANEZCA EN LA POSICI N AP ROPIADA DURANTE LA INSTALACI N DEL ACOPLAMIENTO 7 Aplique 2 3 gotas de LOCT...

Page 19: ...r El ctrico 11 1 Tubo de apoyo Acero inoxidable 12 1 Extensi n del eje AISI 304 12A 1 Eje recubierto con cer mica Art culo N Cantidad Descripci n Material 13 1 Anillo de resorte interno Acero inoxidab...

Page 20: ...erie 300 11 6 Perno del tubo Acero inoxidable Serie 300 12 1 Placa de montaje de la bomba Acero inoxidable Serie 300 13A 1 Cojinete Viton 13B 1 Cojinete Carb n 13C 1 Cojinete EPR 14 1 Buje Acero inoxi...

Page 21: ...considere que existe lugar a un reclamo de garant a deber ponerse en contacto con el distribuidor autorizado de Goulds Water Technology del cual adquiriera la bomba y ofrecer informaci n detallada con...

Page 22: ...22 NPV SHV Mod les SHV et NPV DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN MANUEL D UTILISATION IM101...

Page 23: ...27 Pi ces de rechange s ries NPV et SHV 28 S rie NPV dimensions poids et caract ristiques 9 S rie NPV accessoires de fixation optionnels 9 S rie SHV dimensions poids et caract ristiques 10 S rie SHV...

Page 24: ...arbre n gligeable Les NPV poss dent un moteur NEMA 56J bride de fixation en C et arbre rallonge filet Les SHV viennent avec un moteur NEMA JM standard DONN ES TECHNIQUES Temp rature maximale du liqui...

Page 25: ...rotation Pour inverser la rotation des moteurs triphas s en inter vertir deux des conducteurs UTILISATION CLABOUSSER OU PLONGER UN MOTEUR ABRIT OUVERTURES DE VENTILATION PROT G ES DANS UN LIQUIDE PEUT...

Page 26: ...tube support 7 Immobiliser l arbre rallonge avec une cl de 9 16 po puis y visser SENS HORAIRE la roue S assurer que celle ci est bien appuy e contre la but e de l arbre 8 Appliquez l amorce du LOCTIT...

Page 27: ...sujettir l accouplement avec sa rondelle et sa vis serr e 17 lbf pi NOTA S ASSURER QUE LE JOINT EN U RESTE SA PLACE PENDANT LA POSE DE L ACCOUPLEMENT 7 Mettre 2 ou 3 gouttes de liquide frein pour file...

Page 28: ...bre r rev t c ramique Inox AISI 304 16 2 22 1SR ONLY 7 6 5 4 3 1 21 20 19 18 17 15A 15B 15C 13 14 11 12 12A 8 9 10 23 No d art Quantit Description Mat riau 13 1 Anneau lastique Inox 14 1 Bague de rete...

Page 29: ...ge Inox s rie 300 10 1 Tube support Inox s rie 300 11 6 Vis tube support Inox s rie 300 12 1 Plaque de fixation de la pompe Inox s rie 300 13A 1 Coussinet Viton 13B 1 Coussinet Carbone 13C 1 Coussinet...

Page 30: ...ermique du moteur d clench 2 Disjoncteur ouvert ou fusible saut 3 Roue bloqu e 4 Moteur mal connect 5 Moteur d fectueux 6 Pompe non amorc e air ou gaz pr sent dans le liq uide pomp 7 Tuyau d aspiratio...

Page 31: ...HB HMS LC NPV LB LBS cumplen con las Directivas para Maquinarias 06 42 EC Este equipo ha sido dise ado para ser incorporado a la maquinaria cubierta por esta directiva pero no debe ponerse en funciona...

Page 32: ...uelque nature que ce soit e ni les pertes d coulant de la panne Aux fins de la pr sente garantie les termes ci dessous sont d finis comme suit 1 Distributeur signifie une personne une soci t de person...

Reviews: