XVME-240 Manual
October, 1984

Chapter 1

MODULE DESCRIPTION

1.1 INTRODUCTION

The XVME-240 

Digital Input/Output Module (hereafter referred to as the DIO module)

provides 

VMEbus 

systems with 

80 TTL-level I/O 

channels. The I/O channels are

arranged to provide 8 (byte-wide) bidirectional I/O ports, 8 interrupt input lines, and
and 8 flag output lines. Each bidirectional port can be programmed to either input or
output data.

The 8 interrupt input lines can be used in conjunction with the module

interrupt masking and handling capabilities to generate of VMEbus interrupt on any
level.

Typical applications for the  DIO  module include:

-

TTL-level peripheral control of printers and other parallel port devices.

-

Interfacing with  OPT0  22 compatible devices to control switch inputs,
indicator outputs, and AC/DC applications.

1.2 MANUAL STRUCTURE

The purpose of this first chapter is 

to 

introduce the user to the general specifications

and functional capabilities of the DIO module.

Successive chapters will develop the

various aspects of module installation and operation in the following progression:

Chapter One  - A general description of the DIO module, including complete

functional and environmental specifications, VMEbus compliance information,
and a block diagram.

Chapter Two - Module installation information covering the location of pertinant

module components, switch and jumper options, external connector pin locations,
and standard board installation information.

Chapter Three  - General information needed to use the DIO module including:

module base addressing, module identification data, the Status and Control

register, data port addressing, data direction programming (i.e., Input or Output),

and the interrupt scheme.

The Appendices are designed to introduce and reinforce a variety of module-related
topics including: XYCOM’s  

Standard 

I/O 

Architecture, backplane signal/pin descrip-

tions, a block diagram and schematics, and a quick reference section.

1.3 MODULE OPERATIONAL DESCRIPTION

Figure l- 1 shows an operational block diagram of the DIO module.

l - l

Summary of Contents for XVME-240

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ...s and functional capabilities of the DIO module Successive chapters will develop the various aspects of module installation and operation in the following progression Chapter One A general description...

Page 7: ......

Page 8: ...ort I O Address space I O Interface Block The DIO occupies a IK block of the Short I O Address space called the module I O Interface Block Within this block in standard locations are found the I O reg...

Page 9: ...el output voltage Io1 48mA Io1 16 mA Iol Low level output current Voh High level output voltage Ioh High level output current Voh 2 4V Ioh 2 OV Slave Data Transfer Options A16 D16 STAT A24 D16 STAT In...

Page 10: ...l to 50 000 ft 15240m Vibration Operating 5 to 2000 Hz 0 015 inches peak to peak displacement 2 5 g peak max acceleration Non Operating I 5 to 2000 Hz 030 inches peak to peak displacement 5 0 g peak m...

Page 11: ...employs a Data Transfer Bus Arbiter a Subsystem Clock driver a System Reset driver and a Bus time out module The XYCOM XVME 010 System Resource Module provides a controller subsystem with the compone...

Page 12: ......

Page 13: ...rs for Short I O Address Space or those for Standard Memory space 2 4 l Base Address Switches The DIO module is designed to be addressed within either the VMEbus Short I O or Standard Memory Space Sin...

Page 14: ......

Page 15: ......

Page 16: ...itch 8 must be set to open If jumper J2B is installed Switch 8 must be set to closed The Standard I O Architecture recommends that the DIO operate within the Short I O Address Space in order to take a...

Page 17: ...ed Open Privilege Mode Selected Supervisory or Non Privileged Supervisory Only 2 4 4 Address Modifier Reference The following table Table 2 5 indicates the actual VMEbus Address Modifier code that the...

Page 18: ...nable the IACKIN IACKOUT daisy chain CAUTION The jumper shorting IACKIN to IACKOUT for the DIO s slot in the backplane must be removed or the DIO may be damaged 2 4 6 Interrupt Level Switches Figure 2...

Page 19: ...BGxOUT x 0 thru 3 Since these signals are already hardwired on the DIO it is not necessary to insert these VMEbus jumpers on the slot occupied by the DIO 2 4 8 Interrupt Input Edge Detection Option Th...

Page 20: ...Jl0 If a jumper is set in position A then that interrupt input line will latch the interrupt input on the low to high transition of the signal Likewise if a jumper is set to posi tion B then that int...

Page 21: ......

Page 22: ...3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 12 13 1 14 1 15 1 16 1 17 1 18 1 19 1 20 1 21 1 22 l 23 24 2 5 2 2 6 2 2 7 2 2 8 2 2 9 2 3 0 2 31 2 3 2 2 3 3 2 Definition CONNECTOR JK 1 Data Bit 0 Data Bit 1 Dat...

Page 23: ...rrupt Input Register 4 6 3 Flag Output Line Bit 3 of Flag Output Register 4 7 GND 4 8 GND 4 9 GND 50 GND CONNECTOR JK 2 1 4 Data Bit 0 2 4 Data Bit 1 3 4 Data Bit 2 4 4 Data Bit 3 5 4 Data Bit 4 6 4 D...

Page 24: ...a Bit 4 Data Bit 5 Data Bit 6 Data Bit 7 Interrupt Input Line Bit 6 of Interrupt Input Register Flag Output Line Bit 6 of Flag Output Register GND GND Data Bit 0 Data Bit 1 Data Bit 2 Data Bit 3 Data...

Page 25: ...y for the operation of VMEbus defined NEXP modules The Pl connector is designed to mechanically interface with a VMEbus defined Pl backplane The P2 connector is a standard VMEbus P2 backplane connecto...

Page 26: ......

Page 27: ...of the chassis opening Center the board on the plastic guides so that the solder side is facing to the left and the component side is facing to the right refer to Figure 2 7 Push the card slowly towa...

Page 28: ...DIO module is installed it will occupy a 1K byte block of the Short I O Address space referred to as the module I O Interface Block The starting address for each I O Interface Block must reside on a...

Page 29: ......

Page 30: ...arts at F9OOOOH and if the base address of the DIO is jumpered to 1000H the actual module base address would be F9l000H 3 3 THE DIO I O INTERFACE BLOCK The 1K block of Short I O Address space allotted...

Page 31: ......

Page 32: ...finitions for the DIO Status Control byte STATUS CONTROL REGISTER Base Address 081H Red LED SYSFAIL InterruptPending Interrupt Enable Software Reset User Available Flag Bits Figure 3 2 Status Control...

Page 33: ...Status Module failed or not yet tested Inactive module Module undergoing test Module passed test NOTE The DIO is a non intelligent module so all diagnos tics and configuration checking must be perfor...

Page 34: ...the same time The direction of each port is determined by the contents of the read write Port Direction Register Base address 87H Each bit in the Port Direction register corresponds to one of the I O...

Page 35: ...low user software firmware to determine which externally connected device is sending an interrupt Each interrupt input has its own Interrupt Edge Detection circuitry and interrupt latch refer to Secti...

Page 36: ...be a logic 0 3 3 5 Interrupt Clear Register Base Address 84H The Interrupt Clear Register provides the user with the means to clear interrupt input latches and registers These latches and registers w...

Page 37: ...ear Register should be used after power up or reset to clear all interrupt input latches and registers prior to enabling interrupts SYSRESET and Soft Reset do not clear interrupt input latches 3 3 6 I...

Page 38: ...change the mask is to write a new value to the module base address 83H Writing FFH to the Interrupt Mask Register would pass all latched interrupts and writing 00H to the register would mask out all l...

Page 39: ...rrupt Logic 0 No Pending Interrupt Figure 3 7 Interrupts Pending Register When reading the Interrupts Pending Register Base address 82H a bit containing a 1 means that the corresponding interrupt inpu...

Page 40: ...sed is dependent upon the system processor Please refer to your system processor operating manual for information on interrupt vectors 3 3 9 Flag Outputs Register Base Address 86H The DIO provides 8 F...

Page 41: ...S SUMMARY The DIO module has been designed to receive interrupt input signals from externally connected devices in order to generate a VMEbus Interrupt Request to a system processor There are 8 Interr...

Page 42: ......

Page 43: ...ile the corresponding mask bit is set to 0 it will be prevented from passing through the mask but if the same mask bit is written a 1 before the latch is cleared the interrupt signal will pass through...

Page 44: ...r up or reset 3 Clear Interrupt Input latches and registers by writing to the Interrupt Clears register 4 Write the Vector address which is to be employed by interrupt handling software in the Interru...

Page 45: ...upts The pending interrupts can now be serviced by the handler routine in the same fashion as shown above Interrupts can be disabled in one of three ways 1 By resetting the system i e the Mask Registe...

Page 46: ...of the module to interrupt the system Communication between Modules How master host processors and intelligent I O modules communicate through shared global memory or the dual access RAM on the I O mo...

Page 47: ...ovides the correct address configuration to allow each module address to begin on a 1K boundary Non intelligent XVME modules allow the use of six base address jumpers representing bits Al0 A15 and thu...

Page 48: ...rea of the module I O Interface Block base address 82H roughly l2OF is module specific and it varies in size from one module to the next It is in this area that the module holds specific I O status da...

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...if the board is operating properly On non intelligent XVME I O modules the status control register is used to indicate the state of the front panel LEDs and to set and verify module generated interru...

Page 53: ......

Page 54: ...rnels common from module to module Each different module type consists of a standard kernel combined with module dependent application circuitry Module standardiza tion results in more efficient modul...

Page 55: ......

Page 56: ...l9 C 14 A 18 1A 24 30 ADDRESS bus bits l 23 Three state driven l C 15 30 address lines that specify a memory address Signal Name and Description AC FAILURE open collector driven signal which indicates...

Page 57: ...pole driven signals generated by the Arbiter or Requesters Bus Grant In and Out signals from a daisy chained bus grant The Bus Grant In signal indicates to this board that it may become the next bus m...

Page 58: ...between the DTB master and slave GROUND INTERRUPT ACKNOWLEDGE Open collector or three state driven signal from any Master proces sing an interrupt request Routed via the back plane to Slot 1 where it...

Page 59: ...al may be generated by any module on the VMEbus SYSRESET 1C 12 SYSTEM RESET Open collector driven signal which when low will cause the system to be reset WRITE 1A 14 WRITE Three state driven signal th...

Page 60: ...Row B Row C Signal Signal Signal Mnemonic Mnemonic Mnemonic D00 BBSY DO8 DO1 BCLR DO9 DO2 ACFAIL DlO DO3 BGOIN Dll DO4 I BG0OUT D12 DO5 BGlIN D13 DO6 BGlOUT D14 DO7 BG2IN D15 GND BG20UT GDN SYSCLK BG...

Page 61: ...Number Signal Name and Description 5 Vdc Power Used by system logic circuits 2G 2 12 22 31 Ground ALL OTHER PINS NOT USED BACKPLANE CONNECTOR P2 The following table lists the P2 pin assignments by pi...

Page 62: ......

Page 63: ......

Page 64: ......

Page 65: ......

Page 66: ......

Page 67: ......

Page 68: ......

Page 69: ......

Page 70: ......

Page 71: ...ned Module Identification Undefined I Interrupt inputs Status Control Interrupts Pend Interrupt Mask Interrupt Clear Interrupt Vector Flag Outputs Port Direction I O Port 0 I O Port I I O Port 2 I O P...

Page 72: ...Block Sl Function Selects VMEbus Interrupt Request Level for module I1 17 S2 switches l 6 S2 switch 7 S2 switch 8 Selects Module Base Address This switch works in conjunction with jumper J2 to determi...

Page 73: ......