9450 industrial PC/AT Computer System

4-10

Following are the default keypad key codes produced by the PKIM utility.

Table 4-2. Default Keypad Key Codes

Key

Key Code

Key

Key Code

ESC

76H

.

49H

SHIFT

12H

=

55H

CTRL

14H

¬

E0H, 6BH

ALT

11H

-

E0H, 75H

DEL

E0H, 71H

®

E0H, 74H

PG UP

E0H, 7DH

¯

E0H, 72H

HOME

E0H, 6CH

F1

05H

INSRT

E0H, 70H

F2

06H

PAUSE

E1H, 14H,
77H, F0H

F3

04H

+

79H

F4

0CH

PG DN

E0H, 7AH

F5

03H

END

E0H, 69H

F6

0BH

SPACE

29H

F7

83H

BK SP

66H

F8

0AH

-

7BH

F9

01H

7

3DH

F10

09H

8

3EH

F11

12H, 05H

9

46H

F12

12H, 06H

4

25H

F13

12H, 04H

5

2EH

F14

12H, 0CH

6

36H

F15

12H, 03H

1

16H

F16

12H, 0BH

2

1EH

F17

12H, 83H

3

26H

F18

12H, 0AH

ENTER

5AH

F19

12H, 01H

0

45H

F20

12H, 09H

Summary of Contents for 9450

Page 1: ...9450 Industrial PC AT Computer System P N 99446 001E 1997 XYCOM INC Printed in the United States of America...

Page 2: ...owners Windows is a registered trademark of Microsoft Corp in the United States and other countries Copyright Information This document is copyrighted by Xycom Incorporated Xycom and shall not be rep...

Page 3: ...g the System for Use 3 6 Installing Removing the Slide Out Computer Module 3 7 Removing the Slide Out Computer Module 3 8 Re installing the Slide Out Computer Module 3 8 Installing Internal Hardware O...

Page 4: ...4 3 Macros Menu 4 4 Upload Menu 4 6 Download Menu 4 7 Utilities Menu 4 7 Codes 4 8 Chapter 5 Maintenance 5 1 Preventive Maintenance 5 1 Replacing the External Battery 5 2 Spare Parts List 5 2 Product...

Page 5: ...andards and the CRT is protected with an impact resistant Lexan shield The open architecture design accepts IBM PC XT or AT compatible cards The system comes with a 486 5x86 or Pentium computer instal...

Page 6: ...ts available on 486 configuration Five slots available on Pentium configuration 14 high resolution SVGA color monitor 32 data entry and 20 function keys IDE hard disk MS DOS Slide out computer module...

Page 7: ...r manual CPU manual Business reply card Video driver disk If you ordered the system with SoftScreen installed the documentation kit will include the following SoftScreen Runtime System disks Software...

Page 8: ...ceptacle 3 Attach the power cord from the monitor to the power receptacle Attach the power cord power receptacle to a properly grounded 115 230 VAC 50 60 Hz outlet Attach the power cord to the lower p...

Page 9: ...Menu is configured properly factory set configura tion The way you access the Setup Menu depends on the CPU board installed in your system Phoenix BIOS If the CPU board has a Phoenix BIOS press F2 whe...

Page 10: ...ps below before starting the system test 1 Place the CPU board jumpers and switches to the factory set positions The numbers in parenthesis are the pins onto which to install the jumper e g J1 3 4 ind...

Page 11: ...e Test B Video RAM Test L Speaker Port Test C Extended RAM Test M LPT1 Printer Port Test D Real Time Clock Test N LPT2 Printer Port Test E COM1 Serial Port Test O C Hard Drive Interface Test F COM2 Se...

Page 12: ...for detailed information Warning If your system has a solid state Flash drive installed avoid repeated running of op tion O the hard drive interface test The Flash drive has a limited number of writes...

Page 13: ...s This section describes the 9450 s front and back panel components to familiarize you with the system Front Panel The 9450 comes equipped with a NEMA 4 NEMA12 sealed front panel The panel pro tects t...

Page 14: ...e relegend able System Status LEDs During power up the CPU board checks its hardware configu ration against the configuration information stored in CMOS memory If the power up self test POST is succes...

Page 15: ...Chapter 2 Testing 3 Note 486 CPU boards are installed in Slot 0 and Pentium CPU boards are installed in Slot 1 to accommodate the heat sink...

Page 16: ...he lower power outlet is for the main power source The plug and cord for the AC power and the monitor power must be securely positioned before turning power on Video Connector The 15 pin high density...

Page 17: ...ports are RS 232 and use DB 9 male con nectors The optional built in mouse uses the COM2 port External Battery The 9450 has an external battery located to the right of the PWR Key connector Rear Keyb...

Page 18: ...eptacle 4 Connect the touch screen Note If a touch screen has been factory installed there is an AT adapter board plugged into the backplane in slot 5 Connect the 9 pin cable from the monitor side to...

Page 19: ...odule The slide out computer module shown in Figure Chapter 3 4 allows access to the power supply and disk drives The PC add in boards can be replaced by removing the three screws on the hinged top co...

Page 20: ...les VGA PWR Key Power and optional touch screen 2 Loosen the three thumb screws that attach the slide out computer module to the 9450 back panel 3 Grasp the handle that protrudes from the back panel 4...

Page 21: ...ll internal hardware options through the hinged cover with the module in place Certain mounting configurations require the slide out computer module to be re moved Installation and Removal of the CPU...

Page 22: ...ear the surface of the board When the cable connection is made the latches snap up When removing a cable connector move the latches down near the board This nudges the connector up so you can remove i...

Page 23: ...ws If the slide out com puter module was removed in Step 2 refer to the Re installing the Slide out Module section earlier in this chapter 10 Connect the power sources previously disconnected The 9450...

Page 24: ...ut Module section earlier in this chapter Installing PC Boards Check that the memory and I O configuration of the board you want to install do not con flict with the CPU and I O memory maps as outline...

Page 25: ...A 4 104 key QWERTY key boards with PC AT interfaces The 8000 KB6 and KB7 are rack or panel mounted NEMA 4 numeric keyboards with 52 function keys The keyboards are installed in the same manner Mount t...

Page 26: ...built in serial mouse is located in the lower right hand corner of the front panel The built in mouse operates in the same manner as a conventional mouse Note The built in mouse uses the COM2 port Th...

Page 27: ...RRUS To do this add the following line to your AUTOEXEC BAT file TSRFONT COM After adding this line reboot the system For more information on editing the AUTO EXEC BAT file refer to the MS DOS manual...

Page 28: ...nly ships on CD ROM it does not come on floppy disk If Windows NT was preloaded on your system you may have to purchase an external parallel port CD ROM drive in order to re install Windows NT Install...

Page 29: ...n by installing a thermostat controlled heater or air conditioner Avoid obstructing air flow to allow for maximum cooling Place fans or blowers close to the heat generating devices If using a fan make...

Page 30: ...ly conduct the ground fault current in the system with minimal im pedance The following practices should be observed Separate ground wires from power wires at the point of entry to the enclosure To mi...

Page 31: ...de specifications it is recommended that the high voltage and low voltage cabling be separated and dressed apart In particular the AC ca bles and switch wiring should not be in the same conduit with t...

Page 32: ...ection is made between the chassis and the grounded metal panel 5 Detach the slide out computer module see the Removing the Slide out Computer Module section earlier in this chapter 6 Install the moni...

Page 33: ...hat subdirectory Enter the subdirectory and type PKIM Using the Programmable Keypad Utility The PKIM utility uses a menu bar and pull down menu system All menu bars are dis played across the top of th...

Page 34: ...unless the utility is started with the t switch Utility Batch Mode Versions 2 2 and above of the utility include a mode for reprogramming keypads from a batch file This feature is useful if you wish...

Page 35: ...y ESC can also be used for this purpose and for exiting the other menus Files Menu Files containing keypad macro sets a macro for each key may be saved on disk and loaded into memory to view edit or d...

Page 36: ...back into their original file The original file contents are overwritten Save As Creates a new file under the specified name and copies the set of macros from memory into it For example to define dif...

Page 37: ...displaying the macro in hex or decimal format Default is Hex When Hex is chosen the keycodes are displayed as hexadecimal value scan codes When Decimal is chosen the keycodes are displayed as the dec...

Page 38: ...displays the following choices Exit Cut Copy Paste Codes Hex Decimal and I O Insert Overtype The macro for the chosen key is also displayed Cut Deletes a sequence of scan codes from the macro To selec...

Page 39: ...or the function key keypad Numeric Keypad Commands the PKIM to send its entire macro set for the numeric key keypad Keyboard Commands the PKIM to send its entire macro set for the switch array keyboar...

Page 40: ...OFF Clear EEPROM and Exit Command Description Func Lock ON Turns on the function key interlock feature The function key interlock disables all function keys as long as one function key is pressed onl...

Page 41: ...key keyboard en hanced keys in macros that use these keys The special scan codes are listed below Table 4 1 Special PKIM Scan Codes Code Description E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE Insert Home...

Page 42: ...LT 11H E0H 75H DEL E0H 71H E0H 74H PG UP E0H 7DH E0H 72H HOME E0H 6CH F1 05H INSRT E0H 70H F2 06H PAUSE E1H 14H 77H F0H F3 04H 79H F4 0CH PG DN E0H 7AH F5 03H END E0H 69H F6 0BH SPACE 29H F7 83H BK SP...

Page 43: ...onments where shock could loosen the connections Check to see that all plugs sockets terminal strips and mod ule connections are solid Remove unnecessary articles like drawings or manuals from the uni...

Page 44: ...chen Typ aus Zur Entsorgung mussan Sie Lithium Batterien an ihren Handler zuruckgeben The 9450 has an external battery located to the right of the PWR Key connector To re place the battery 1 Use a scr...

Page 45: ...erating condition and to implement engineering changes which enhance operat ing specifications Products returned to Xycom will be tested with standard Xycom test diagnostics Contact PR C at 1 800 AT X...

Page 46: ...mbly is properly at tached to the unit and the slide out module is secured by all three fasteners 3 To speed processing attach failure information to the unit 4 Place the unit securely in a heavy duty...

Page 47: ...19 483 mm 16 5 419 mm 60 lbs 27 2 kg Electrical 115 230 VAC 3 3 A 50 60 Hz 200 watts Power Supply 150 Watts Derated Backplane Seven slot AT passive backplane 7 AT slots 150 watts available to backplan...

Page 48: ...cifications Characteristic Specification Temperature Operating Non operating 0 to 50 C 32 to 122 F 40 to 60 C 40 to 140 F Humidity Operating Non operating 20 to 80 RH non condensing 20 to 80 non conde...

Page 49: ...and is also TUV ap proved to the following specifications Underwriter Laboratories Inc UL508 Industrial Control Equipment Canadian Standards Association C22 2 14 Industrial Control Equipment TUV Cert...

Page 50: ......

Page 51: ...Appendix B Block Diagrams Dimensions Inserts Figure B 1 System Block Diagram...

Page 52: ...Note Material 010 thk Aluminum with 090 thk domes Epoxy resin in the front side of the 3M 468 adhesive on the back side Figure B 2 9450 Logo Dimensions...

Page 53: ...Appendix B Block Diagrams Dimensions Inserts 3 Note Material 010 thk textured polyester overlay resin on the front side and 3M 467 adhesive on the back side Figure B 3 9450 Function Key Overlay...

Page 54: ...Note Material 007 thk polyester with factory clear hardcoat on the front side and UV velvet on the back side Figure B 4 9450 15 Key Insert...

Page 55: ...Appendix B Block Diagrams Dimensions Inserts 5 Figure B 5 8000 KB5 and 8000 KB6 Keyboard Cutout Dimensions A full size template is available by calling customer support at 1 800 289 9266...

Page 56: ...Figure B 6 9450 System Cutout Dimensions...

Page 57: ...Appendix B Block Diagrams Dimensions Inserts B 7...

Page 58: ...tors located on the I O side of the unit Table C 1 COM1 COM2 Serial Port Pinouts Pin Signal Pin Signal 1 3 5 7 9 DCD TXD GND RTS RI 2 4 6 8 RXD DTR DSR CTS VGA Connector The VGA is a 15 pin connector...

Page 59: ...0 11 12 13 STROBE PD0 PD1 PD2 PD3 PD4 PD5 PD6 PD7 PACK PBUSY PE SELECT 14 15 16 17 18 19 20 21 22 23 24 25 AUTOFEED PERROR INIT SELIN GND GND GND GND GND GND GND GND Keyboard Connectors Two standard f...

Page 60: ...nouts C 3 Speaker Jack The speaker jack is a subminiature phone jack located on the CPU board Refer to the CPU manual for more information Table C 5 Speaker Jack Pin Signal Pin Signal Tip Sleeve Sourc...

Page 61: ...9450 Industrial PC AT Computer System C 4...

Page 62: ...10 installation 3 11 removal 3 11 D data entry keypad 3 3 derating power supply 3 20 diagnostic LEDs 3 3 diagnostics 2 1 dimensions 8000 KB5 keyboard 3 13 B 5 8000 KB6 keyboard 3 14 B 5 8000 KB7 keybo...

Page 63: ...N noise excessive 3 19 O ON OFF switch 3 4 optional items 1 2 P panel installation 3 16 parallel port 3 5 parallel port LPT1 2 PC boards installation 3 12 pinouts keyboard connector 2 parallel port LP...

Page 64: ...3 removal 3 8 software compatible 1 1 spare parts list 5 2 speaker jack 3 specifications environmental A 2 hardware A 1 standard features 1 2 system cutout dimensions B 6 system power 3 18 system stat...

Page 65: ...strial PC AT Computer System Index 4 T testing 2 1 touch screen cable 3 5 U unit returning 5 3 unpacking the system 1 3 V VGA connector 1 video connector 3 4 video controls 3 4 video drivers installat...

Reviews: