XtremepowerUS 75025 Owner'S Manual And Safety Instructions Download Page 5

Brief Introduction

This

 

variable

 

speed

 

pump

 

is

 

designed to

 

operate

 

your

 

swimming

 

pool filtration

 

system

 

as

 

well

 

as

 

your

 

spa,

 

waterfall,

 

cleaner,

 

heater,

 

salt

 

chlorine

 

system

 

and

 

other

 

water

 

applications.

Using the

 

control

 

panel,

 

you

 

can

 

run

 

your

 

pump

 

on

 

one

 

of three

 

scheduled

 

programs:

1.

Regular

 

mode

:

 

use

 

three

 

quick

 

start

 

buttons.

ECO

 

(default

 

1500RPM)/CLEAN(

 

default

 

2400RPM)/BOOST(

 

default

 

3250RPM),

 

and then

 

adjust the

 

pump

 

to

 

run

 

at the

 

your

 

preferred.

2.

Mode 1

:

 

16

 

hours

 

for

 

each

 

clean

 

cycle.

3.

Mode 2

:

 

24

 

hours

 

for

 

each

 

clean

 

cycle.

The

 

control

 

panel

 

also

 

has

 

LED

 

indicators

 

for

 

speed

 

as

 

well

 

as

 

alarm

 

indicator

 

and

 

error

 

code to

 

warn the

 

user

 

on the

 

voltage

 

problems,

 

excessive temperature,

 

over

 

current

 

and

 

freeze

 

protection

 

etc.

1.

 

Features

 

of

 

LED

 

Control

 

Panel

 

1

!

Display

 

and

 

change time.

 

2

!

Display

 

and

 

change

 

running

 

speed.

 

3

!

Quick-start

 

button

 

of

 

ECO/CLEAN/BOOST to

 

run

 

on

 

different

 

speeds.

 

4

!

MODE1/MODE2

 

for

 

scheduled

 

programs

 

(16

 

hours

 

or

 

24

 

hours

 

clean

 

cycle).

 

   

 

 

 

 

 

5

!

Re-start

 

and

 

reset to

 

normal

 

schedule

 

after

 

over

 

current,

 

over

 

voltage,

 

over

 

heat,

 

or

 

unexpected

 

power

 

off.

 

6

!

Keep

 

records

 

of

 

scheduled

 

programs

 

for

 

max

 

15

 

days

 

after

 

power

 

off.

 

7

!

Run

 

5

 

minutes

 

at

 

high

 

speed

 

after the

 

start

 

8

!

Step-by-step

 

acceleration

 

and

 

deceleration

 

of

 

the

 

speed to

 

extend the

 

use

 

life

 of the motor and 

control panel

5

Summary of Contents for 75025

Page 1: ......

Page 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or installed or used in applications other than for which the pump was intended can result in serious personal injury or death These risks may include but not be limited to electric shock fire flooding suction ...

Page 3: ...tion of the pump requires the prior consent of the manufacturer Original replacement parts and accessories authorized by the manufacturer ensure a high level of safety The manufacturer of the pump assumes no liability for the damage and injuries caused by un authorized replacement parts and accessories 6 During operation some parts of the pump are subject to dangerous electric voltage Work may onl...

Page 4: ...4 ...

Page 5: ...lso has LED indicators for speed as well as alarm indicator and error code to warn the user on the voltage problems excessive temperature over current and freeze protection etc 1 Features of LED Control Panel 1 Display and change time 2 Display and change running speed 3 Quick start button of ECO CLEAN BOOST to run on different speeds 4 MODE1 MODE2 for scheduled programs 16 hours or 24 hours clean...

Page 6: ... Composed of four digital tubes Display current time when standby And display the current and running speed back and forth in operation AM PM Designed for 12 hour system If pump run on 0 00 11 59 AM light on if pump run on 12 00 23 59 PM light on MODE1 and MODE 2 have 4 stages S1 S2 S3 S4 is the speed for each stage If the S1 light is on the pump is run on first stage if the light twinkles the tim...

Page 7: ...nd S3 first press CLEAN if not work you will need to stop the pump first After 5 minutes high speed running press CLEAN then press arrow button to increase or decrease RPM When press MODE 1 or MODE 2 again to run the pump S1 and S3 will run as just selected To adjust S2 and S4 first press ECO if not work you will need to stop the pump After 10 minutes high speed running press ECO then press arrow ...

Page 8: ...ning when change the time after 11 59 the time change to 0 00 PM light will shine 2 After time set up press ENTER to save and quit Don t press ENTER if you would like to continue to change the specification of MODE1 and MODE 2 Press MENU again the light of MODE 1 and S1 will shine screen display 6 00 and AM light is shine Use arrow buttons to adjust the time When the time is over 11 59 PM light wi...

Page 9: ...10 ...

Page 10: ...Control Panel Menu Structure 11 ...

Page 11: ...29080 Strainer Housing O Ring 1 7 5212016000 Screw ST5 5 25 8 8 47252702080 Diffuser 1 9 64727297130 Impeller 1 10 5431040080 Housing O Ring 1 11 5028003000 Seal Assembly 1 12 47252701080 Pump Housing 1 13 47252708080 Motor Mounting Plate 1 14 5023410000 Motor 1 15 41038005 Mounting Foot 1 16 5224025000 Screw M5 14 4 17 5432002080 O Ring 1 18 48860105080 Drain Plug 1 12 ...

Page 12: ... 1 Locked rotor short circuit of motor wire or excessive temperature rise of the driver 2 Input voltage is too high 4 6 8 Input voltage is too low When the power is turned off the pump still can work for a while as the remaining electricity in its energy storage elements and then the alarm code 8 will be displayed which is normal At this time if you want to restart please wait until the screen is ...

Page 13: ...024 0 4001 4002 4096 After power off it will takes more than ten seconds to restart as the internal energy storage elements need to be discharged The pump may work abnormally if the circuit board is restarted before the power is discharged If it occurs power off and wait for a while to power on again 14 ...

Page 14: ......

Reviews: