background image

 

www.XtremeAirUsa.com

                                                                    PAGE 

9

 

 

F.    Remote Control Sensor: 

1.

  Remote control sensor receives infrared (IR) signal from the remote control. The maximum distance for IR data transmission is 10 

feet and requires direct line of sight. The transmission distance may vary depending on temperature and remote control battery 
condition.

 

2.    Light settings are independent from other settings (including power-off delay) and lights have to be manually turned on or off.   

3.

  The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is   

 

    turned on. 
 

2.    FOR PX01, PX03,PX04, PX04-B, & D02 Model: TYPE 2: BUTTON TOUCH CONTROL PANEL   

 

 

 

 
 

 
 
 
 
 
 
 
 

Importance Notice: 

1.  2 ½ HOUR AUTOMATIC SHUT OFF: this range hood will be shut off for every approx. 2 ½ hour.    You can re-start 

operation as usual after it was shut off. 

2.

  30 HOUR REMINDER:    after 30 hours of use, the timer (8) will be flashing. To clear it, please refer to “G-To Clear 

Cleaning Reminder” on page 7.

 

 
A.  ACTIVATING BLOWER FUNCTION: 

  Option 1: Touch and hold down (+) for 1-2 seconds. 

  Option 2: Touch and hold down power sign (1) for 1-2 seconds. (The blower will be running at the same speed as last used). 

Note

: The system saves user configurations, settings such as timer and blower (motor) speed will remain the same the next time it is turned on. 

 
B.  ADJUSTING BLOWER SPEED: 

  Touch and hold down (+) for increase. 

  Touch and hold down (-) for decrease. 

 
C.  TURNING OFF THE BLOWER: 

  Touch and hold down power sign (1) for 1-2 seconds.       

 
D.  TO TURN THE LIGHT ON/OFF: 

  Touch Light button (6) once to turn on the lights, and once again to turn off the lights. 

 
E.  ADJUSTING THE TIMER FUNCTION:   

  While the blower (motor) is not running, touch and hold Decrease Value button (2) 1-2 seconds or until it’s flashing to enter timer mode.   

  Adjust to desired period of delay off timer by touching Increase Value or Decrease Value 

button (minimum 1 minute to maximum 15 minutes). 

This setting will be saved immediately.   

 

F. ACTIVATING THE TIMER FUNCTION:   

  While the blower (motor) is running, touch and hold “Power” button (1) for 1-2 seconds til you see “BLUE L” to activate delay off timer.   

Power-Off Delay 

Timer Indicator

 (10) will light up and 

Power-Off Delay Digital Timer

 (9) will begin to countdown.    When it reaches zero, the blower (motor) will shut down.

 

 
G.  TO CLEAR CLEANING REMINDER: 

  When blower (motor) starts to rotate, cumulative running time will be shown in 

Power-On Elapsed Digital Timer (8)

. This timer icon flashes when 30 hours 

is up and reminds user to clean the baffle filters.   

  After cleaning the filters and when the motor is not in use, touch and hold (+) 

Increase Value 

button (7) over 3 seconds to reset the timer. Please note 

that turning off the system will not reset the 

Power-On Elapsed Digital Timer (8)

.   

 

 

Summary of Contents for Deluxe DL08-W36

Page 1: ...IONS FOR RESIDENTIAL INDOOR USE ONLY Pro X Series PX01 W30 36 PX02 W30 36 PX03 W30 36 PX04 W30 36 42 PX04 W30 36 42 B PX06 W30 36 42 48 Ultra Series D02 W30 36 UL02 W30 36 UL03 W30 36 Deluxe Series DL08 W36 42 48 INSTALLATION GUIDE USER S MANUAL WALL MOUNT RANGE HOOD ...

Page 2: ...is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It is recommended tha...

Page 3: ...all joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended...

Page 4: ... 2 2 2 2 2 W A S WALL ANCHOR SCREW 4 4 4 4 4 4 4 4 4 C S UPPER INNER CHIMNEY SCREW 4 ATTACHE D 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED C G CAPONY GLASS 1 N A N A N A N A N A N A N A ATTACHE D B F BAFLE FILTERS 2 3 2 30 3 36 N A ATTACH ED ATTACH ED 3 4 ATTACH ED A P ALUMINUM PIPE 1 1 1 1 1 1 1 0 1 A D AIR DIVERTER N A N A N A N A N A N A N A 1 N A D C...

Page 5: ...www XtremeAirUsa com PAGE 5 8 HOOD DIMENSIONS INSTALLATION OVERVIEW PX08 W36 42 PX04 W30 36 42 PX06 W30 36 42 PX08 W48 PX02 W30 36 UL02 W30 36 PX03 W30 36 UL03 W30 36 PX01 W30 36 ...

Page 6: ...B Level the hood body by using horizontal level C Use hand screw driver to tighten those 2 mounting screws D Connect the exhaust on the hood to the ductwork above E Use aluminum tape to make all joints secure and all tight F Find the three pronged plug and connect to an electrical outlet CAUTION Do not release the hood until you finish step 6 below STEP 2 MARKING ON THE WALL A Center is the center...

Page 7: ...d Operation Try a few test runs to ensure machine is running properly STEP 6A FOR PX01 MODEL ONLY INSTALL GLASS CANOPY A Loosen the four canopy screws and washers from the hood top B Carefully place the canopy glass on the hood top then slightly tighten the four canopy screws along with washers DO NOT put excessive pressure against the glass 10 BAFLE FILTERS INSTALL REMOVAL IMPORTANCE FOR THOSE MO...

Page 8: ...tion 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working D Activating Smoke Detector Function ...

Page 9: ...ll remain the same the next time it is turned on B ADJUSTING BLOWER SPEED Touch and hold down for increase Touch and hold down for decrease C TURNING OFF THE BLOWER Touch and hold down power sign 1 for 1 2 seconds D TO TURN THE LIGHT ON OFF Touch Light button 6 once to turn on the lights and once again to turn off the lights E ADJUSTING THE TIMER FUNCTION While the blower motor is not running touc...

Page 10: ...otice 1 If the range hood or lights does not operate after installation Check if the range hood has been plugged in Make sure that all power has been turned back ON Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs 2 The range hood vibrates when the blower is on The range hood might not have been secured properly to the cabinet or wall Check if the blowe...

Page 11: ...commended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Clea...

Page 12: ...www XtremeAirUsa com PAGE 12 16 LIMITED WARRANTY ...

Reviews: