background image

 

www.XtremeAirUsa.com

                                                                    PAGE 

10

 

 

3.    FOR ALL ULTRA SERIES: TYPE 3: MECHANICAL BUTTON CONTROL   
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.    FOR DL08 & DL09 Model: TYPE 4: ELECTRONIC BUTTON CONTROL   

 
 
 
 
 
 
 

 
 
 
 

 

 

 

OTHER THAN DL08-W48 

DL09-W48 

Body Design   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Power Rating   

120V/60Hz (USA & Canada standard) 

120V/60Hz (USA & Canada standard) 

General Input Power   

158W (150W + 4x2W) 

308W (150W + 4x2W) 

Motor Input Power   

150 W each 

150 W each 

Ampere   

1.3 A 

2.6 A 

Levels Of Speed Control 

4 Levels 

4 Levels 

Maximum Airflow 

900CFM 

1600CFM 

Noise Level 

Approximately 1.5 – 6.0 sones or 33 – 54 dB 

Approximately 3.0 – 7.0 sones or 41 – 56 dB 

Number Of Motors   

Single Motor 

2 Motors 

Motor Type   

Single Chamber Ultra Quiet 

Single Chamber Ultra Quiet 

Fan Type   

Squirrel Cage blower 

2 Squirrel Cage blowers 

Filtration Type   

Heavy Duty Stainless Steel Baffle Filter 

Heavy Duty Stainless Steel Baffle Filter 

Illumination   

2/3/4 LED lights, 2W Maximum/each 

4 LED lights, 2W Maximum/each 

Venting Size   

Top 6 inches Round 

Top 8 inches Round 

Interference Protection   

Radio Frequency Interference Protected 

Radio Frequency Interference Protected 

Note 

Specification subject to change without notice. 

Specification subject to change without notice. 

 
 
 

1.    If the range hood or lights does not operate after installation: 

  Check if the range hood has been plugged in.    Make sure that all power has been turned back ON.   

 

Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs.   

 

 

2.    The range hood vibrates when the blower is on: 

 

The range hood might not have been secured properly to the cabinet or wall. 

 

Check if the blower wheel is damaged.       

12. SPECIFICATION 

13. TROUBLESHOOTING 

A. Activating Blower Function: 

Press (0) once (flashing) 

Press your designed speed (1,2,3,4) 

B. Active delay power shut off / turn off power: 

While the blower (motor) is running, press (0) once to active 3 min power delay shut off 

Press (0) again to turn off blower and power. 

C. To turn the light ON/OFF & Dimmer 

While the light is off, press (5) once to turn on the light 

Press (5) again to turn dimmer down to lower setting 

Press (5) again to turn the light off. 

 

 

A. Activating Blower Function: 

Press your designed speed (1,2,3) 

B. Turn off power: 

While the blower (motor) is running, press button (0) to turn off the motors. 

C. To turn the light ON/OFF 

While the light is off, press button (4) once to turn on the light. 

Press button (4) again to turn the light off

 

 

A.Make sure the range hood is unplugged or turn OFF breaker.   
B.Pop out the light by pressing behind the light fixture. 
C.Install new light bulb. 
D.Put the light set back by pressing it in. 
E.Plug in and range hood to test for operation. 

 

Summary of Contents for Deluxe DL08-W36

Page 1: ...IONS FOR RESIDENTIAL INDOOR USE ONLY Pro X Series PX01 W30 36 PX02 W30 36 PX03 W30 36 PX04 W30 36 42 PX04 W30 36 42 B PX06 W30 36 42 48 Ultra Series D02 W30 36 UL02 W30 36 UL03 W30 36 Deluxe Series DL08 W36 42 48 INSTALLATION GUIDE USER S MANUAL WALL MOUNT RANGE HOOD ...

Page 2: ...is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It is recommended tha...

Page 3: ...all joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended...

Page 4: ... 2 2 2 2 2 W A S WALL ANCHOR SCREW 4 4 4 4 4 4 4 4 4 C S UPPER INNER CHIMNEY SCREW 4 ATTACHE D 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED C G CAPONY GLASS 1 N A N A N A N A N A N A N A ATTACHE D B F BAFLE FILTERS 2 3 2 30 3 36 N A ATTACH ED ATTACH ED 3 4 ATTACH ED A P ALUMINUM PIPE 1 1 1 1 1 1 1 0 1 A D AIR DIVERTER N A N A N A N A N A N A N A 1 N A D C...

Page 5: ...www XtremeAirUsa com PAGE 5 8 HOOD DIMENSIONS INSTALLATION OVERVIEW PX08 W36 42 PX04 W30 36 42 PX06 W30 36 42 PX08 W48 PX02 W30 36 UL02 W30 36 PX03 W30 36 UL03 W30 36 PX01 W30 36 ...

Page 6: ...B Level the hood body by using horizontal level C Use hand screw driver to tighten those 2 mounting screws D Connect the exhaust on the hood to the ductwork above E Use aluminum tape to make all joints secure and all tight F Find the three pronged plug and connect to an electrical outlet CAUTION Do not release the hood until you finish step 6 below STEP 2 MARKING ON THE WALL A Center is the center...

Page 7: ...d Operation Try a few test runs to ensure machine is running properly STEP 6A FOR PX01 MODEL ONLY INSTALL GLASS CANOPY A Loosen the four canopy screws and washers from the hood top B Carefully place the canopy glass on the hood top then slightly tighten the four canopy screws along with washers DO NOT put excessive pressure against the glass 10 BAFLE FILTERS INSTALL REMOVAL IMPORTANCE FOR THOSE MO...

Page 8: ...tion 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working D Activating Smoke Detector Function ...

Page 9: ...ll remain the same the next time it is turned on B ADJUSTING BLOWER SPEED Touch and hold down for increase Touch and hold down for decrease C TURNING OFF THE BLOWER Touch and hold down power sign 1 for 1 2 seconds D TO TURN THE LIGHT ON OFF Touch Light button 6 once to turn on the lights and once again to turn off the lights E ADJUSTING THE TIMER FUNCTION While the blower motor is not running touc...

Page 10: ...otice 1 If the range hood or lights does not operate after installation Check if the range hood has been plugged in Make sure that all power has been turned back ON Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs 2 The range hood vibrates when the blower is on The range hood might not have been secured properly to the cabinet or wall Check if the blowe...

Page 11: ...commended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Clea...

Page 12: ...www XtremeAirUsa com PAGE 12 16 LIMITED WARRANTY ...

Reviews: